Adaptive servo-ventilation in heart failure with sleep-disordered breathing (ADVENT-HF): no effect on the primary composite outcome (hazard ratio 0.95 relative) or on mortality over 3.6 years, despite abolishing the disordered breathing (documented N = 731 randomised)

Shelf #11393 · Lungs, breathing & sleep

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with heart failure with reduced ejection fraction and sleep-disordered breathing (obstructive or central), does adding peak-flow-triggered adaptive servo-ventilation to standard care improve cardiovascular outcomes? (The SERVE-HF question — servo-ventilation in predominantly central apnoea — is owned by shelf #2795 and is not rebuilt here.)

Balance of the evidence

POSSIBLE (the treatment made no difference) — a single large phase 3 trial (731 patients randomised; single trial, so Tier C despite its size). ADVENT-HF enrolled patients with heart failure and reduced ejection fraction (left ventricular ejection fraction 45% or less) and sleep-disordered breathing (apnoea–hypopnoea index at least 15 events per hour), stratified as predominantly obstructive (with Epworth score 10 or lower) or predominantly central, and randomised them to standard care alone or standard care plus peak-flow-triggered adaptive servo-ventilation. The device worked on its target — mean apnoea–hypopnoea index fell to 2.8–3.7 events per hour — but over a mean 3.6 years it had no effect on the primary composite of all-cause mortality, first cardiovascular hospital admission, new atrial fibrillation or flutter, or appropriate defibrillator shock (166 events on servo-ventilation versus 180 on control; hazard ratio 0.95 relative, 95% CI 0.77 to 1.18; P = 0.67), nor on all-cause mortality (76 versus 88 deaths; hazard ratio 0.89 relative, 95% CI 0.66 to 1.21; P = 0.47). No safety issue related to servo-ventilation was identified — in contrast to SERVE-HF (shelf #2795), where a different (flow-triggered) device in predominantly central apnoea increased cardiovascular mortality. The boundary matters: this shelf is the mixed obstructive/central, peak-flow-triggered question; SERVE-HF's harm record stands separately at #2795 and is not softened by this null. Enrolment ended early because of COVID-19 restrictions and the trial was terminated after a device recall over motor sound-abatement material, both stated on the face.

MeSH: Humans · Stroke Volume · Sleepiness · Ventricular Function, Left · Canada · Sleep Apnea Syndromes* · Heart Failure* · Sleep Apnea, Central* · Sleep Apnea, Obstructive* · Treatment Outcome

Cards (2)

Card 1 — ADVENT-HF 2024: servo-ventilation abolished sleep-disordered breathing (index down to 2.8–3.7 events per hour) but did not change the composite outcome (HR 0.95 relative) or mortality (HR 0.89 relative) over 3.6 years

Study: Randomised controlled trial, phase 3, open-label with blinded outcome assessment (731 patients randomised)

Population: Multicentre, multinational, parallel-group, open-label phase 3 randomised trial at 49 hospitals in nine countries: 731 patients aged 18 or older with heart failure and reduced ejection fraction (left ventricular ejection fraction ≤45%), stabilised on optimal medical therapy, with sleep-disordered breathing (apnoea–hypopnoea index ≥15 events per hour) — predominantly obstructive or predominantly central — were randomised to standard care (375) or standard care plus peak-flow-triggered adaptive servo-ventilation (356), with blinded outcome assessment. The primary endpoint was the composite of all-cause mortality, first cardiovascular hospital admission, new-onset atrial fibrillation or flutter, and appropriate defibrillator shock.

Summary: ADVENT-HF 2024: servo-ventilation abolished sleep-disordered breathing (index down to 2.8–3.7 events per hour) but did not change the composite outcome (HR 0.95 relative) or mortality (HR 0.89 relative) over 3.6 years

Result: Over mean follow-up of 3.6 years (SD 1.6), servo-ventilation had no effect on the primary composite outcome (166 events versus 180 in control; hazard ratio 0.95 relative, 95% CI 0.77 to 1.18; P = 0.67) or on all-cause mortality (76 versus 88 deaths; hazard ratio 0.89 relative, 95% CI 0.66 to 1.21; P = 0.47). Mortality hazard ratios by apnoea type were 1.00 relative for obstructive (95% CI 0.68 to 1.46) and 0.74 relative for central (95% CI 0.44 to 1.23), neither significant. Mean apnoea–hypopnoea index on servo-ventilation fell to 2.8–3.7 events per hour, with improved sleep quality at 1 month. No safety issue related to servo-ventilation use was identified. Forty-one participants (6%) withdrew consent and 34 (5%) were lost to follow-up.

Watch out: Enrolment terminated prematurely because of COVID-19 restrictions and the trial was stopped after a recall of the servo-ventilation device (potential disintegration of motor sound-abatement material), so the trial is smaller and shorter than planned; the null is a genuine null within those limits, not proof of exact equivalence. Open-label design, though outcomes were assessed blinded.

Source: Bradley TD, Logan AG, Lorenzi Filho G et al.. Adaptive servo-ventilation for sleep-disordered breathing in patients with heart failure with reduced ejection fraction (ADVENT-HF): a multicentre, multinational, parallel-group, open-label, phase 3 randomised controlled trial. Lancet Respir Med. 2024. PMID: 38142697. Registry IDs: NCT01128816, ISRCTN67500535. MeSH: Humans · Stroke Volume · Sleepiness · Ventricular Function, Left · Canada · Sleep Apnea Syndromes* · Heart Failure* · Sleep Apnea, Central* · Sleep Apnea, Obstructive* · Treatment Outcome

Card 2 — Synthesis: in heart failure with sleep-disordered breathing, normalising breathing with this servo-ventilation device did not translate into fewer deaths, admissions, arrhythmias or shocks — a null, and not the harm SERVE-HF found

Study: Synthesis

Population: The carded record: ADVENT-HF alone (731 patients randomised). Total documented N = 731.

Summary: Synthesis: in heart failure with sleep-disordered breathing, normalising breathing with this servo-ventilation device did not translate into fewer deaths, admissions, arrhythmias or shocks — a null, and not the harm SERVE-HF found

Result: A single trial caps the stamp at POSSIBLE even at this size; the stamp records the null plainly — (the treatment made no difference) — on hard outcomes, while the face keeps the contrast with SERVE-HF (shelf #2795) explicit so the two records are not merged.

Watch out: Do not generalise this null across devices or populations: SERVE-HF's mortality harm was with a different trigger algorithm in predominantly central apnoea, and phrenic nerve stimulation for central apnoea (shelf #11389) is a separate question with only surrogate-endpoint evidence.

Source: Synthesis of the carded record above (PMID 38142697). Registry IDs: NCT01128816, ISRCTN67500535.