High-flow oxygen for bronchiolitis: escalation of care in 12% versus 23% in the 1,472-infant trial and treatment failure in 14% versus 33% in the 202-infant trial — but no shorter time on oxygen or in hospital in either trial (documented N = 1,674 randomised across two trials)

Shelf #11439 · Children’s health

LIKELY (benefit)

Stamped: 2026-11-28.

Evidence published: 2017–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In infants and young children with bronchiolitis who need supplemental oxygen, does high-flow nasal cannula oxygen (high-flow warm humidified oxygen), compared with standard low-flow oxygen, reduce treatment failure and escalation of care, shorten time on oxygen or hospital stay?

Balance of the evidence

LIKELY (benefit) — Composition: two independent randomised trials (1,674 infants and young children in total), concordant on the outcome they share. In the 1,472-infant multicentre trial, escalation of care for treatment failure occurred in 12% (87/739) on high-flow oxygen versus 23% (167/733) on standard oxygen (risk difference −11 percentage points; 95% CI −15 to −7; P < 0.001). In the 202-child single-centre trial, treatment failure occurred in 14% (14/101) on high-flow warm humidified oxygen versus 33% (33/101) on standard low-flow oxygen (P = 0.0016). In both trials, about 61% of children who failed standard therapy responded to rescue high-flow. What high-flow did not do in either trial is shorten the illness: the smaller trial's primary outcome, time to weaning off oxygen, was 20 hours versus 24 hours (hazard ratio 0.9; P = 0.61), and the large trial found no difference in duration of hospital stay or of oxygen therapy, and intensive care transfer was not reduced in the smaller trial (14% versus 12%). The benefit this shelf claims is therefore narrower than the practice it supports: fewer failures of the first oxygen strategy, not a faster recovery. Heliox for bronchiolitis is homed at #4716, chest physiotherapy at #9430 and montelukast after bronchiolitis at #7986; this shelf answers only high-flow versus standard low-flow oxygen.

MeSH: Bronchiolitis / therapy* · Child, Preschool · Female · Hot Temperature* · Humans · Humidity · Infant · Infant, Newborn · Infant, Premature · Infant, Premature, Diseases / therapy · Intensive Care Units · Kaplan-Meier Estimate · Length of Stay · Male · Oxygen Inhalation Therapy / adverse effects · Oxygen Inhalation Therapy / methods* · Patient Transfer · Treatment Failure · Treatment Outcome

Cards (3)

Card 1 — PARIS-era multicentre trial 2018: escalation of care in 12% on high-flow oxygen versus 23% on standard oxygen (1,472 infants); no difference in hospital stay or oxygen duration

Study: Randomised controlled trial, multicentre (1,472 infants analysed)

Population: Multicentre randomised trial in Australia and New Zealand: 1,472 infants younger than 12 months with bronchiolitis needing supplemental oxygen, treated outside intensive care, assigned to high-flow oxygen therapy (2 L/kg/min) or standard oxygen therapy; infants failing standard therapy could receive rescue high-flow. The primary outcome was escalation of care due to treatment failure (meeting at least 3 of 4 criteria: persistent tachycardia, tachypnoea, hypoxaemia, and medical review triggered by an early-warning tool).

Summary: PARIS-era multicentre trial 2018: escalation of care in 12% on high-flow oxygen versus 23% on standard oxygen (1,472 infants); no difference in hospital stay or oxygen duration

Result: Escalation of care occurred in 12% (87/739) of the high-flow group versus 23% (167/733) of the standard-therapy group (risk difference −11 percentage points; 95% CI −15 to −7; P < 0.001). There were no significant differences in duration of hospital stay or duration of oxygen therapy. One case of pneumothorax (<1%) occurred in each group. Of the 167 infants who failed standard therapy, 102 (61%) responded to rescue high-flow therapy.

Watch out: Open-label by necessity — the devices cannot be masked — and escalation of care is partly a clinician decision, so the failure endpoint is softer than intubation or death, neither of which the trial showed to differ.

Source: Franklin D, Babl FE, Schlapbach LJ et al. A Randomized Trial of High-Flow Oxygen Therapy in Infants with Bronchiolitis. N Engl J Med. 2018. PMID: 29562151. Registry ID: ACTRN12613000388718. MeSH: Bronchiolitis / therapy* · Female · Humans · Infant · Infant, Newborn · Infant, Premature · Infant, Premature, Diseases / therapy · Intensive Care Units · Kaplan-Meier Estimate · Length of Stay · Male · Oxygen Inhalation Therapy / adverse effects · Oxygen Inhalation Therapy / methods* · Patient Transfer · Treatment Failure

Card 2 — HFWHO trial 2017: time to weaning off oxygen was not shortened (20 versus 24 hours, P = 0.61), but treatment failure was 14% versus 33% (202 children)

Study: Randomised controlled trial, open, phase 4 (202 children randomised)

Population: Open, phase 4, single-centre randomised trial at one Australian children's hospital: 202 children younger than 24 months with moderate bronchiolitis assigned to high-flow warm humidified oxygen (maximum 1 L/kg/min to 20 L/min) or standard therapy (cold wall oxygen by nasal cannulae to a maximum of 2 L/min). The primary outcome was time from randomisation to last use of oxygen therapy.

Summary: HFWHO trial 2017: time to weaning off oxygen was not shortened (20 versus 24 hours, P = 0.61), but treatment failure was 14% versus 33% (202 children)

Result: Median time to weaning was 20 hours (95% CI 17–34) on high-flow versus 24 hours (95% CI 18–28) on standard therapy (hazard ratio 0.9; 95% CI 0.7–1.2; log rank P = 0.61) — no significant difference. Fewer children failed treatment on high-flow (14 [14%] versus 33 [33%]; P = 0.0016), and 20 (61%) of the 33 children failing standard therapy were rescued with high-flow. Intensive care transfer was 14% on high-flow versus 12% on standard therapy (P = 0.41). Four adverse events occurred, none causing withdrawal.

Watch out: This trial's own primary outcome was negative: read alone it supports high-flow as rescue, not as a disease-shortening first treatment. Its flow rate (1 L/kg/min) was also half the large trial's (2 L/kg/min).

Source: Kepreotes E, Whitehead B, Attia J et al. High-flow warm humidified oxygen versus standard low-flow nasal cannula oxygen for moderate bronchiolitis (HFWHO RCT): an open, phase 4, randomised controlled trial. Lancet. 2017. PMID: 28161016. Registry ID: ACTRN12612000685819. MeSH: Bronchiolitis / therapy* · Child, Preschool · Female · Hot Temperature* · Humans · Humidity · Infant · Infant, Newborn · Male · Oxygen Inhalation Therapy / methods* · Treatment Outcome

Card 3 — Synthesis: two trials agree that high-flow cuts failure of the first oxygen strategy roughly in half, and agree just as clearly that it does not shorten oxygen time or hospital stay

Study: Synthesis

Population: The carded record: the 2018 multicentre trial (1,472 infants) and the 2017 HFWHO trial (202 children); total documented N = 1,674, independent trials, additive.

Summary: Synthesis: two trials agree that high-flow cuts failure of the first oxygen strategy roughly in half, and agree just as clearly that it does not shorten oxygen time or hospital stay

Result: Both trials found treatment failure or escalation in about half as many children on high-flow as on standard oxygen (12% versus 23%; 14% versus 33%), and in both, 61% of standard-therapy failures were rescued by high-flow. Neither trial found faster weaning, shorter oxygen therapy or shorter stay. That pattern — concordant on failure, concordant null on duration — earns LIKELY (benefit) for the failure outcome, with the duration null printed on the face.

Watch out: Children already in intensive care, and high-flow compared with CPAP rather than with low-flow oxygen, are outside this record; neither trial showed a difference in intubation or death.