SourceMed · Shelf #11451 in the ask interface

Foley catheter versus prostaglandin for induction at term: caesarean rates were much the same in all three PROBAAT trials (23% versus 20% against gel; 20% versus 22% against inserts; 20.1% Foley versus 16.8% oral misoprostol), with fewer side-effects and less hyperstimulation on the catheter (documented N = 2,909)

Shelf #11451 · Women’s health

LIKELY (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2011–2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women with an unfavourable cervix at term who need induction of labour, does a transcervical Foley catheter achieve vaginal birth as safely and effectively as prostaglandin — vaginal prostaglandin E2 gel or inserts, or oral misoprostol?

Balance of the evidence

LIKELY (the treatment made no difference) — Composition: three independent open-label randomised trials from one Dutch research programme (2,909 women), concordant on the caesarean outcome. Against vaginal prostaglandin E2 gel (PROBAAT, 824 women), caesarean section was 23% with a 30 mL Foley catheter versus 20% with gel (risk ratio 1.13 relative, 95% CI 0.87 to 1.47). Against slow-release prostaglandin E2 inserts (PROBAAT-P, 226 women analysed), caesarean was 20% versus 22% (risk ratio 0.90 relative, 95% CI 0.54 to 1.50), and the accompanying meta-analysis found significantly fewer cases of hyperstimulation with the catheter. Against oral misoprostol (PROBAAT-II, 1,859 women), the composite of asphyxia or postpartum haemorrhage of at least 1,000 mL was 11.5% on Foley versus 12.2% on misoprostol (adjusted relative risk 1.06 relative for misoprostol versus Foley, 90% CI 0.86 to 1.31), inside the 5% non-inferiority margin, with caesarean 20.1% versus 16.8%. The two serious maternal adverse events in PROBAAT (uterine perforation and uterine rupture) both occurred in the prostaglandin-gel group. So the catheter and the prostaglandins deliver babies equally well; the catheter's advantage is a quieter uterus and fewer side-effects, not a lower caesarean rate. Oral misoprostol compared with intravenous oxytocin is a different question, homed on shelf #11268.

MeSH: Administration, Intravaginal · Administration, Oral · Adult · Apgar Score · Asphyxia Neonatorum / etiology · Catheterization / adverse effects · Catheterization / methods* · Catheterization* / adverse effects · Catheters* · Cervical Ripening · Cervical Ripening / drug effects · Cesarean Section · Delivery, Obstetric · Delivery, Obstetric / methods · Dinoprostone / administration & dosage* · Dinoprostone / adverse effects · Drug Administration Schedule · Female · Humans · Infant, Newborn · Labor, Induced / adverse effects · Labor, Induced / instrumentation · Labor, Induced / methods* · Misoprostol / administration & dosage* · Misoprostol / adverse effects · Oxytocics / administration & dosage* · Oxytocics / adverse effects · Postpartum Hemorrhage / etiology · Pregnancy · Randomized Controlled Trials as Topic / instrumentation · Randomized Controlled Trials as Topic / methods* · Term Birth · Urinary Catheterization / instrumentation · Vaginal Creams, Foams, and Jellies

Cards (4)

Card 1 — PROBAAT 2011: Foley catheter versus prostaglandin E2 gel — caesarean section 23% versus 20% (risk ratio 1.13 relative), with both serious maternal adverse events in the gel group

Study: Randomised controlled trial, open-label (824 women allocated)

Population: Open-label randomised trial in 12 Dutch hospitals: 824 women with a term singleton cephalic pregnancy, intact membranes, an unfavourable cervix, an indication for induction and no previous caesarean section, allocated to a 30 mL Foley catheter (412) or vaginal prostaglandin E2 gel (412). The primary outcome was caesarean section rate.

Summary: PROBAAT 2011: Foley catheter versus prostaglandin E2 gel — caesarean section 23% versus 20% (risk ratio 1.13 relative), with both serious maternal adverse events in the gel group

Result: Caesarean section rates were 23% on Foley versus 20% on gel (risk ratio 1.13 relative, 95% CI 0.87 to 1.47) — no significant difference, confirmed by the meta-analysis the authors ran including their own trial. Two serious maternal adverse events were recorded, both in the prostaglandin group: one uterine perforation and one uterine rupture. The authors conclude the methods are similar in effectiveness, with fewer maternal and neonatal side-effects on the catheter.

Watch out: Open-label by necessity and run in women without a previous caesarean — the record does not cover induction with a scarred uterus, where prostaglandin safety concerns differ.

Source: Jozwiak M, Oude Rengerink K, Benthem M et al.. Foley catheter versus vaginal prostaglandin E2 gel for induction of labour at term (PROBAAT trial): an open-label, randomised controlled trial. Lancet. 2011. PMID: 22030144. Registry ID: NTR1646 (Netherlands Trial Register, stated in the record). MeSH: Adult · Catheterization* / adverse effects · Cervical Ripening · Cesarean Section · Delivery, Obstetric · Dinoprostone / administration & dosage* · Dinoprostone / adverse effects · Female · Humans · Labor, Induced / methods* · Oxytocics / administration & dosage* · Oxytocics / adverse effects · Pregnancy · Vaginal Creams, Foams, and Jellies

Card 2 — PROBAAT-II 2016: Foley catheter versus oral misoprostol — composite of asphyxia or haemorrhage at least 1,000 mL in 11.5% versus 12.2%, meeting non-inferiority; caesarean 20.1% versus 16.8%

Study: Randomised controlled trial, open-label non-inferiority (1,859 women randomised)

Population: Open-label randomised non-inferiority trial in 29 Dutch hospitals: 1,859 women with a term singleton cephalic pregnancy, unfavourable cervix, intact membranes and no previous caesarean section, assigned to oral misoprostol 50 micrograms every 4 hours (932) or a 30 mL transcervical Foley catheter (927). The primary outcome was a composite of asphyxia (pH at most 7.05 or 5-minute Apgar below 7) or postpartum haemorrhage of at least 1,000 mL; the non-inferiority margin was 5%.

Summary: PROBAAT-II 2016: Foley catheter versus oral misoprostol — composite of asphyxia or haemorrhage at least 1,000 mL in 11.5% versus 12.2%, meeting non-inferiority; caesarean 20.1% versus 16.8%

Result: The composite occurred in 106 of 921 women (11.5%) on Foley versus 113 of 924 (12.2%) on misoprostol (adjusted relative risk 1.06 relative, 90% CI 0.86 to 1.31) — similar safety and effectiveness. Caesarean section occurred in 185 women (20.1%) on Foley versus 155 (16.8%) on misoprostol (relative risk 0.84 relative for misoprostol, 95% CI 0.69 to 1.02; P = 0.067). Adverse events numbered 25 versus 27, none directly related to the study procedure.

Watch out: Non-inferiority was judged on a composite dominated by haemorrhage volume; the caesarean point estimate actually favoured misoprostol, so this trial supports interchangeability, not catheter superiority.

Source: ten Eikelder MLG, Oude Rengerink K, Jozwiak M et al.. Induction of labour at term with oral misoprostol versus a Foley catheter (PROBAAT-II): a multicentre randomised controlled non-inferiority trial. Lancet. 2016. PMID: 26850983. Registry ID: NTR3466. MeSH: Administration, Oral · Adult · Apgar Score · Asphyxia Neonatorum / etiology · Catheterization / adverse effects · Catheterization / methods* · Cervical Ripening / drug effects · Delivery, Obstetric / methods · Drug Administration Schedule · Female · Humans · Infant, Newborn · Labor, Induced / adverse effects · Labor, Induced / methods* · Misoprostol / administration & dosage* · Misoprostol / adverse effects · Oxytocics / administration & dosage* · Oxytocics / adverse effects · Postpartum Hemorrhage / etiology · Pregnancy · Term Birth · Urinary Catheterization / instrumentation

Estimate type: adjusted estimate, as stated in the card.

Card 3 — PROBAAT-P 2013: Foley catheter versus prostaglandin E2 inserts — caesarean 20% versus 22%; the trial's own meta-analysis found less hyperstimulation with the catheter

Study: Randomised controlled trial, open-label, with systematic review (226 women analysed)

Population: Open-label randomised trial in five Dutch hospitals: 226 women analysed with a singleton term cephalic pregnancy, intact membranes, unfavourable cervix and no previous caesarean section, allocated to a 30 mL Foley catheter (107) or 10 mg slow-release vaginal prostaglandin E2 inserts (119); the primary outcome was caesarean section rate, and the authors added a systematic review and meta-analysis of similar studies.

Summary: PROBAAT-P 2013: Foley catheter versus prostaglandin E2 inserts — caesarean 20% versus 22%; the trial's own meta-analysis found less hyperstimulation with the catheter

Result: Caesarean section rates were comparable (20% versus 22%; risk ratio 0.90 relative, 95% CI 0.54 to 1.50), secondary outcomes did not differ, and no serious maternal or neonatal morbidity was observed. The meta-analysis confirmed comparable caesarean rates and showed significantly fewer cases of hyperstimulation during the ripening phase with a Foley catheter.

Watch out: The smallest of the three trials (226 women) — its confidence interval (0.54 to 1.50) is wide; it corroborates the two larger trials rather than standing alone.

Source: Jozwiak M, ten Eikelder M, Oude Rengerink K et al.. Foley catheter or prostaglandin E2 inserts for induction of labour at term: an open-label randomized controlled trial (PROBAAT-P trial) and systematic review of literature. Eur J Obstet Gynecol Reprod Biol. 2013. PMID: 23870188. Registry ID: not stated in the record. MeSH: Administration, Intravaginal · Adult · Catheters* · Dinoprostone / administration & dosage* · Female · Humans · Labor, Induced / instrumentation · Labor, Induced / methods* · Oxytocics / administration & dosage* · Pregnancy · Randomized Controlled Trials as Topic / instrumentation · Randomized Controlled Trials as Topic / methods*

Card 4 — Synthesis: three concordant trials — the Foley catheter and prostaglandins are interchangeable for getting labour started; the catheter trades drug side-effects and hyperstimulation away, not caesareans

Study: Synthesis

Population: The carded record: PROBAAT (824 women, versus gel), PROBAAT-II (1,859 women, versus oral misoprostol) and PROBAAT-P (226 women, versus inserts); total documented N = 2,909, independent trials, additive.

Summary: Synthesis: three concordant trials — the Foley catheter and prostaglandins are interchangeable for getting labour started; the catheter trades drug side-effects and hyperstimulation away, not caesareans

Result: Caesarean rates sit within a few points of each other in every comparison and every confidence interval crosses no difference — that is why the stamp reads LIKELY (the treatment made no difference) and is not Tier C: the two-trial gate is met three times over. The consistent secondary finding is less hyperstimulation and fewer side-effects with the mechanical method.

Watch out: All three trials excluded women with a previous caesarean section and required intact membranes; where the catheter is placed and the woman sent home is a separate question, on shelf #11452.

Source: Synthesis of the carded records above (PMIDs 22030144, 26850983, 23870188). Registry IDs: NTR1646, NTR3466.