SourceMed · Shelf #11504 in the ask interface
1-litre bowel preparation NER1006 (PLENVU): non-inferior to trisulfate for overall cleansing success (85.1% versus 85.0%) and superior to 2-litre PEG with ascorbate in per-protocol analyses (overall success 97.3% versus 92.2%; high-quality right-colon cleansing 32.3% versus 15.9%) — equal or better cleansing at half the volume (documented N = 1,470 randomised across two phase 3 trials)
Shelf #11504 · Liver & gut
LIKELY (the treatment made no difference on overall cleansing versus trisulfate, with superior right-colon cleansing versus 2-litre PEG in per-protocol analysis)
Stamped: 2026-11-28.
Evidence published: 2018–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults preparing for colonoscopy, does the 1-litre polyethylene glycol preparation NER1006 clean the colon as well as higher-volume preparations — trisulfate solution or 2-litre polyethylene glycol with ascorbate — when given in split-dose regimens?
Balance of the evidence
LIKELY (the treatment made no difference on overall cleansing, with a right-colon advantage in one trial's per-protocol analysis) — Composition: two independent phase 3 randomised non-inferiority trials of the same tested product, total documented N = 1,470 randomised. The product is named exactly as published — NER1006, marketed as PLENVU, a 1-litre polyethylene glycol preparation with ascorbate — because cleansing performance belongs to a specific formulation, not to low-volume preparations in general. Against trisulfate solution (DeMicco 2018; 621 randomised, 556 evaluated), NER1006 met non-inferiority for overall cleansing success (85.1% versus 85.0%) and for high-quality ascending-colon cleansing (35.9% versus 29.3%). Against 2-litre polyethylene glycol with ascorbate (Bisschops 2019; 849 randomised, 822 in the modified full analysis set), non-inferiority was established in the primary analysis, and per-protocol analyses favoured NER1006: overall success 97.3% versus 92.2% (P = 0.014) and high-quality right-colon cleansing 32.3% versus 15.9% (P < 0.001). Treatment-related adverse events were somewhat more frequent with NER1006 than trisulfate (14.9% versus 9.4%) without compromising adherence, which was very high in both arms. Both trials used split dosing (evening/morning, or morning-only in one Bisschops arm); split-dose timing itself is homed on shelf #4238 and simethicone as an adjunct on shelf #5684 — neither is rebuilt here.
MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cathartics / administration & dosage* · Cathartics / adverse effects · Colon / drug effects* · Colonoscopy / methods* · Female · Humans · Male · Middle Aged · Patient Compliance / statistics & numerical data · Patient Satisfaction / statistics & numerical data · Polyethylene Glycols / administration & dosage* · Polyethylene Glycols / adverse effects · Young Adult · Ascorbic Acid / pharmacology* · Cathartics* / administration & dosage · Cathartics* / adverse effects · Cathartics* / pharmacology · Colon / diagnostic imaging* · Drug Monitoring / methods · Europe · Outcome Assessment, Health Care · Patient Preference · Polyethylene Glycols* / administration & dosage · Polyethylene Glycols* / adverse effects · Polyethylene Glycols* / pharmacology · Potassium Chloride / pharmacology · Preoperative Care* / methods · Preoperative Care* / psychology · Sodium Chloride / pharmacology · Sulfates / pharmacology
Cards (3)
Card 1 — DeMicco 2018 (NOCT study): 1 L NER1006 was non-inferior to trisulfate — overall cleansing success 85.1% versus 85.0%, high-quality right-colon cleansing 35.9% versus 29.3%
Study: Randomised controlled trial, phase 3 non-inferiority (621 patients randomised, 556 evaluated)
Population: Randomised, multicentre, colonoscopist- and central-reader-blinded phase 3 non-inferiority trial: 621 patients undergoing colonoscopy randomised (1:1) to NER1006 (310) or trisulfate solution (311), both as evening/morning split dosing; 556 patients were evaluated for efficacy (276 and 280). Blinded central readers scored cleansing with the Harefield Cleansing Scale against two primary endpoints — overall cleansing success and high-quality cleansing of the ascending colon/caecum — with a 10% non-inferiority margin. Boston Bowel Preparation Scale scores, lesion detection and adherence were secondary.
Summary: DeMicco 2018 (NOCT study): 1 L NER1006 was non-inferior to trisulfate — overall cleansing success 85.1% versus 85.0%, high-quality right-colon cleansing 35.9% versus 29.3%
Result: NER1006 achieved non-inferiority on both primary endpoints: overall cleansing success 85.1% versus 85.0% (difference 0.14%; one-sided 97.5% lower confidence limit −8.15%; P = 0.528) and high-quality ascending-colon/caecum cleansing 35.9% versus 29.3% (difference 6.58%; lower confidence limit −1.69%; P = 0.059). Lesion detection rates were similar. Treatment-related adverse events occurred in 14.9% on NER1006 and 9.4% on trisulfate; tolerability, safety profiles and adherence (very high in both arms) were otherwise similar.
Watch out: Sixty-five randomised patients were not evaluated for efficacy, and the non-inferiority margin was a generous 10 percentage points — 'non-inferior' here means within that margin on a cleansing scale, judged by central readers, not identical performance in routine lists.
Source: DeMicco MP, Clayton LB, Pilot J, Epstein MS. Novel 1 L polyethylene glycol-based bowel preparation NER1006 for overall and right-sided colon cleansing: a randomized controlled phase 3 trial versus trisulfate. Gastrointest Endosc. 2018. PMID: 28803744. Registry ID: NCT02254486. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cathartics / administration & dosage* · Cathartics / adverse effects · Colon / drug effects* · Colonoscopy / methods* · Female · Humans · Male · Middle Aged · Patient Compliance / statistics & numerical data · Patient Satisfaction / statistics & numerical data · Polyethylene Glycols / administration & dosage* · Polyethylene Glycols / adverse effects · Young Adult
Card 2 — Bisschops 2019 (DAYB study): NER1006 versus 2 L PEG with ascorbate — non-inferior overall, and superior in per-protocol analyses (97.3% versus 92.2% overall; 32.3% versus 15.9% high-quality right-colon cleansing)
Study: Randomised controlled trial, phase 3 (849 patients randomised)
Population: Phase 3 randomised, blinded, multicentre trial in Europe: 849 patients undergoing colonoscopy randomised (1:1:1) to NER1006 as an evening/morning regimen, NER1006 as a morning-only regimen, or 2-litre polyethylene glycol with ascorbate (2LPEG) evening/morning. Cleansing was scored centrally with the Harefield Cleansing Scale and the Boston Bowel Preparation Scale; primary endpoints were overall cleansing success and high-quality right-colon cleansing, analysed in the modified full analysis set (822 patients) and per protocol (670 patients).
Summary: Bisschops 2019 (DAYB study): NER1006 versus 2 L PEG with ascorbate — non-inferior overall, and superior in per-protocol analyses (97.3% versus 92.2% overall; 32.3% versus 15.9% high-quality right-colon cleansing)
Result: The modified full analysis set established non-inferiority. Per protocol, the evening/morning NER1006 regimen was superior to 2LPEG for overall success (97.3% versus 92.2%; P = 0.014), and both NER1006 regimens were superior for high-quality right-colon cleansing (32.3% and 34.4% versus 15.9%; both P < 0.001). Mean segmental cleansing scores favoured NER1006, right-colon polyp detection was higher with evening/morning NER1006 (P = 0.024), and adherence, tolerability and safety were comparable between treatments.
Watch out: The superiority figures come from the per-protocol population, which excludes non-adherent patients and so flatters both arms; the primary (modified full analysis) conclusion is non-inferiority, and that is the claim the stamp leads with.
Source: Bisschops R, Manning J, Clayton LB, Ng Kwet Shing R. Colon cleansing efficacy and safety with 1 L NER1006 versus 2 L polyethylene glycol + ascorbate: a randomized phase 3 trial. Endoscopy. 2019. PMID: 30025414. Registry IDs: NCT02273167; EudraCT 2014-002185-78 (both as stated in the record). MeSH: Ascorbic Acid / pharmacology* · Cathartics* / administration & dosage · Cathartics* / adverse effects · Cathartics* / pharmacology · Colon / diagnostic imaging* · Colonoscopy / methods* · Drug Monitoring / methods · Europe · Female · Humans · Male · Middle Aged · Outcome Assessment, Health Care · Patient Preference · Polyethylene Glycols* / administration & dosage · Polyethylene Glycols* / adverse effects · Polyethylene Glycols* / pharmacology · Potassium Chloride / pharmacology · Preoperative Care* / methods · Preoperative Care* / psychology · Sodium Chloride / pharmacology · Sulfates / pharmacology
Card 3 — Synthesis: one litre cleans as well as two — the low-volume preparation matches standard preparations on overall cleansing and may clean the right colon better, at the cost of somewhat more treatment-related adverse events than trisulfate
Study: Synthesis
Population: The carded record: DeMicco 2018 (621 randomised) and Bisschops 2019 (849 randomised); total documented N = 1,470 randomised, independent trials, additive.
Summary: Synthesis: one litre cleans as well as two — the low-volume preparation matches standard preparations on overall cleansing and may clean the right colon better, at the cost of somewhat more treatment-related adverse events than trisulfate
Result: Two phase 3 trials against two different comparators agree that NER1006 is not worse than standard-volume preparation, meeting the two-trial gate for a LIKELY no-difference stamp on overall cleansing. The claim is formulation-specific: it does not license assuming every low-volume preparation performs identically. Split-dose timing (#4238) is a separate, additive decision.
Watch out: Patients with renal impairment, heart failure or electrolyte risk were not the focus of these trials, and both trials' preparations contain ascorbate and electrolytes in fixed formulation — product-specific cautions sit with the formulation, not with this comparison.
Source: Synthesis of the carded records above (PMIDs 28803744, 30025414). Registry IDs: NCT02254486, NCT02273167.