Does small-incision lenticule extraction (SMILE) match femtosecond LASIK on visual quality and patient experience in myopia?

Balance of the evidence

POSSIBLE: The randomised evidence is two small trials with equivalence-shaped results. In the paired-eye trial (70 patients, one eye SMILE and one LASIK), subjective visual symptoms did not differ at 3 months, though SMILE caused more intraoperative discomfort during tissue manipulation and more blurring at 1 month. In the parallel trial (SMILE 113 eyes, FS-LASIK 84 eyes), uncorrected acuity was worse with SMILE on day 1 but identical by 6 months, with less induced spherical aberration after SMILE. The wider SMILE literature is dominated by cohort series and meta-analyses of them, which is itself stated here: two small RCTs with short follow-up earn POSSIBLE, not more.

MeSH: Corneal Stroma/surgery · Corneal Surgery, Laser · Dry Eye Syndromes/physiopathology · Glare · Intraoperative Period · Keratomileusis, Laser In Situ/methods · Lasers, Excimer/therapeutic use

Cards (3)

Card 1 — Paired-eye trial (2018): symptoms equal by 3 months; more discomfort during SMILE tissue manipulation, more blurring at 1 month

Study: Prospective, randomised, paired-eye, single-masked clinical trial (Singapore National Eye Centre)

Population: 70 patients with myopia, randomly treated with SMILE in one eye and femtosecond LASIK in the other, completing intraoperative questionnaires immediately after surgery and postoperative questionnaires at 1 and 3 months. Mean age and sex mix are not stated in the abstract.

Summary: Paired-eye trial (2018): symptoms equal by 3 months; more discomfort during SMILE tissue manipulation, more blurring at 1 month.

Result: Average discomfort was higher during tissue manipulation in SMILE (1.9 ± 0.9) than during flap lifting in LASIK (1.59 ± 0.8) (P=.020), but comparable during docking and laser application. Fear was lower in SMILE during docking (2.6 ± 1.6 vs 3.4 ± 1.9, P=.024) and similar at other stages. At 1 month, patients reported more blurring after SMILE than LASIK (2.1 ± 0.8 vs 1.8 ± 0.7, P=.025); at 3 months there were no differences in any visual symptom.

Watch out: Seventy patients, subjective endpoints, single centre, 3 months — a patient-experience trial, not an acuity or safety trial; rare complications (the outcomes that decide between these operations at population scale) cannot be assessed at this size.

Source: Damgaard IB et al. Intraoperative Patient Experience and Postoperative Visual Quality After SMILE and LASIK in a Randomized, Paired-Eye, Controlled Study. J Refract Surg. 2018;34(2):92-99. PMID: 29425387. Registry ID: none in the record's databank fields — this trial report's record carries no databank registry field.

Card 2 — Parallel RCT (2016): day-1 acuity favoured FS-LASIK, 6-month acuity identical; less spherical aberration after SMILE

Study: Prospective, randomised, comparative study

Population: 197 eyes with myopia or myopic astigmatism — SMILE in 113 eyes (mean spherical equivalent −5.22 ± 1.70 diopters) and femtosecond LASIK in 84 eyes (−5.18 ± 1.93 D) — with acuity, contrast sensitivity and higher-order aberrations measured to 6 months. The abstract does not state mean age or sex mix.

Summary: Parallel RCT (2016): day-1 acuity favoured FS-LASIK, 6-month acuity identical; less spherical aberration after SMILE.

Result: Uncorrected distance visual acuity was better in the FS-LASIK group on postoperative day 1 (P<0.05), with no significant difference at 6 months (P=0.9). Corrected distance acuity and mean spherical equivalent did not differ during follow-up. Contrast sensitivity was lower in the SMILE group at 1 day and 1 week. At 6 months, spherical aberration (6 mm diameter) was lower after SMILE (0.12 ± 0.22 µm) than FS-LASIK (0.28 ± 0.26 µm) (P<0.05). Both procedures achieved good visual outcomes.

Watch out: Eyes, not patients, are the unit (197 eyes), follow-up is 6 months, and enhancement rates and ectasia — long-horizon outcomes — are outside the frame. No registry ID in the record's databank fields.

Source: Liu M et al. Clinical Outcomes After SMILE and Femtosecond Laser-Assisted LASIK for Myopia and Myopic Astigmatism: A Prospective Randomized Comparative Study. Cornea. 2016;35(2):210-6. PMID: 26684046. Registry ID: none in the record's databank fields — this trial report's record carries no databank registry field.

Card 3 — Synthesis: by three to six months the two operations converge — POSSIBLE

Study: Synthesis

Population: Synthesis of the cards above: the paired-eye trial (70 patients) and the parallel trial (197 eyes).

Summary: Synthesis: by three to six months the two operations converge — POSSIBLE.

Result: SMILE's early course is slightly rougher (more manipulation discomfort, worse day-1 acuity, more early blurring), its aberration profile slightly cleaner, and by 3–6 months patients cannot tell the procedures apart on symptoms or acuity. Femtosecond assistance in cataract surgery (Shelf #892) is a different operation and is not re-carded here.

Watch out: Neither trial can speak to rare but decisive harms; equivalence claims on this shelf are about vision and experience, not about lifetime corneal safety.