SourceMed · Shelf #11583 in the ask interface

CGM in pregnancy with type 1 diabetes (CONCEPTT): HbA1c fell 0.19 percentage points more with CGM, time in target 68% versus 61%, and large-for-gestational-age infants were fewer (odds ratio 0.51 relative) (documented N = 325 across the pregnancy and planning-pregnancy trials; 215 pregnant)

Shelf #11583 · Diabetes, glucose & metabolism

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In pregnant women with type 1 diabetes, does adding continuous glucose monitoring to capillary glucose monitoring improve maternal glucose control and neonatal outcomes?

Balance of the evidence

POSSIBLE (benefit) — Composition: one multicentre randomised trial programme run as two parallel trials (total documented N = 325 randomised: 215 pregnant women and 110 women planning pregnancy; counted once). In pregnant women, CGM added to capillary monitoring produced a small HbA1c advantage (mean difference −0.19 percentage points; P = 0.0207), more time in target (68% versus 61%; P = 0.0034) and fewer large-for-gestational-age infants (odds ratio 0.51 relative; P = 0.0210), neonatal intensive care admissions over 24 hours (odds ratio 0.48 relative) and neonatal hypoglycaemia (odds ratio 0.45 relative). No apparent benefit was found in women planning pregnancy — printed on the card. The HbA1c and time-in-target endpoints are glycaemic surrogates; the neonatal endpoints are clinical but come from one trial, so the stamp is POSSIBLE with tierC true. This is a narrowed build: automated insulin delivery in type 1 diabetes pregnancy (AiDAPT) is homed at shelf #2633 and CGM in gestational diabetes at shelf #2740; neither is rebuilt. Skin reactions were the commonest adverse event (48% of CGM participants during pregnancy).

MeSH: Adolescent · Adult · Blood Glucose / analysis · Diabetes Mellitus, Type 1 / diagnosis · Diabetes Mellitus, Type 1 / drug therapy · Female · Humans · Insulin / administration & dosage · Internationality · Monitoring, Physiologic / methods · Observer Variation · Odds Ratio · Pregnancy · Pregnancy Outcome* · Risk Assessment · Severity of Illness Index · Young Adult

Cards (2)

Card 1 — CONCEPTT 2017: CGM in pregnant women with type 1 diabetes — HbA1c −0.19 points more, time in target 68% versus 61%, and fewer large babies (odds ratio 0.51 relative); no benefit in women planning pregnancy

Study: Randomised controlled trial (325 women randomised across two parallel trials; CONCEPTT)

Population: Multicentre open-label randomised controlled trial at 31 hospitals: 325 women aged 18–40 years with type 1 diabetes for at least 12 months on intensive insulin therapy — 215 pregnant (at or before 13 weeks 6 days' gestation) and 110 planning pregnancy — assigned to CGM plus capillary glucose monitoring (108 pregnant, 53 planning) or capillary monitoring alone (107 pregnant, 57 planning). The primary outcome was change in HbA1c from randomisation to 34 weeks' gestation (pregnant) or to 24 weeks or conception (planning).

Summary: CONCEPTT 2017: CGM in pregnant women with type 1 diabetes — HbA1c −0.19 points more, time in target 68% versus 61%, and fewer large babies (odds ratio 0.51 relative); no benefit in women planning pregnancy

Result: In pregnant women, HbA1c improved slightly more with CGM (mean difference −0.19%; 95% CI −0.34 to −0.03; P = 0.0207). Pregnant CGM users spent more time in target (68% versus 61%; P = 0.0034) and less time hyperglycaemic (27% versus 32%; P = 0.0279), with comparable severe hypoglycaemia episodes (18 CGM versus 21 control) and time spent hypoglycaemic (3% versus 4%; P = 0.10). Neonatal outcomes improved: large for gestational age (odds ratio 0.51 relative; 95% CI 0.28 to 0.90; P = 0.0210), neonatal intensive care admissions over 24 hours (0.48 relative; 0.26 to 0.86; P = 0.0157), neonatal hypoglycaemia (0.45 relative; 0.22 to 0.89; P = 0.0250), and hospital stay 1 day shorter (P = 0.0091). No apparent benefit of CGM was found in women planning pregnancy. Skin reactions were the most common adverse event (49 of 103 CGM participants [48%] during pregnancy).

Watch out: The maternal glycaemic gains are small (−0.19 HbA1c points) and the neonatal benefits, while clinical, rest on this single trial; absolute neonatal event rates are not printed in the abstract, so the size of the absolute benefit cannot be stated from this record. The planning-pregnancy trial was null and is part of this shelf's verdict.

Source: Feig DS, Donovan LE, Corcoy R et al.. Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial. Lancet (London, England). 2017. PMID: 28923465. Registry ID: NCT01788527 (as stated in the record). MeSH: Adolescent · Adult · Blood Glucose / analysis · Diabetes Mellitus, Type 1 / diagnosis · Diabetes Mellitus, Type 1 / drug therapy · Female · Humans · Insulin / administration & dosage · Internationality · Monitoring, Physiologic / methods · Observer Variation · Odds Ratio · Pregnancy · Pregnancy Outcome* · Risk Assessment · Severity of Illness Index · Young Adult

Card 2 — Synthesis: one trial programme supports CGM in established pregnancy with type 1 diabetes, not before conception — POSSIBLE (benefit)

Study: Synthesis

Population: The carded record: the CONCEPTT programme only (215 pregnant women; 110 planning pregnancy); total documented N = 325.

Summary: Synthesis: one trial programme supports CGM in established pregnancy with type 1 diabetes, not before conception — POSSIBLE (benefit)

Result: CGM modestly improved maternal glucose control and several neonatal outcomes in pregnant women, with no apparent benefit in women planning pregnancy. A single trial programme caps the stamp at POSSIBLE. Automated insulin delivery in type 1 diabetes pregnancy is homed at shelf #2633 (AiDAPT) and CGM in gestational diabetes at shelf #2740.

Watch out: CONCEPTT predates current factory-calibrated sensors; the record's skin-reaction rate (48%) belongs to the devices of 2013–2016 and is reported as the trial found it.

Source: Synthesis of the carded records above (PMID 28923465). Registry ID: NCT01788527.