Ultrasound-guided cannulation of difficult dialysis access: first-attempt success 96% versus 72% in one randomised trial, and fewer additional needle passes (72 versus 99 events) and skin punctures (10 versus 25) in another; pain results conflicted and no patency outcome was tested (documented N = 82 patients)
Shelf #11645 · Kidney, fluids & electrolytes
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2021–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In haemodialysis patients with difficult-to-cannulate arteriovenous fistulas, does ultrasound-guided cannulation improve cannulation success and reduce needle passes compared with the conventional landmark technique?
Balance of the evidence
POSSIBLE (benefit) — Composition: two independent single-centre randomised trials in difficult-to-cannulate arteriovenous fistulas (50 patients; 32 participants with 346 randomised cannulation events); total documented N = 82 patients. Both trials found more accurate cannulation with ultrasound guidance — first-attempt success 96% versus 72.0%, additional needle passes 72 versus 99 events, additional skin punctures 10 versus 25. Pain fell in one trial (1.48 versus 2.13) and was unchanged in the other; cannulation time was unchanged in one and prolonged in the other. The stamp is Tier C: the samples are small, one trial randomised events rather than patients, and no trial followed fistula patency or complications. Neighbouring access questions are homed elsewhere: cannulation technique (buttonhole versus stepladder) #1733, access surveillance with preemptive correction #9770, drug-coated balloons for dysfunctional fistulas #1594, stent grafts for failing grafts #2924 and far-infrared therapy for maturation #2085.
MeSH: Arteriovenous Fistula* · Arteriovenous Shunt, Surgical* · Arteriovenous Shunt, Surgical* / adverse effects · Catheterization / adverse effects · Catheterization / methods · Humans · Kidney Failure, Chronic* · Pain · Renal Dialysis / methods · Renal Dialysis* · Ultrasonography · Ultrasonography, Interventional
Cards (3)
Card 1 — Randomised trial 2023: handheld ultrasound guidance raised first-attempt cannulation success in difficult arteriovenous access from 72.0% to 96% and lowered pain scores (1.48 versus 2.13), with no increase in cannulation time
Study: Randomised controlled trial (50 patients randomised)
Population: Single-centre randomised controlled trial in a hospital dialysis unit: 50 haemodialysis patients with complex (difficult-to-cannulate) arteriovenous fistulas were randomised to ultrasound-guided or conventional cannulation by 10 renal nurses trained in the technique by an interventional nephrologist. Outcomes included first-attempt success (only one cannulation attempt required), pre-cannulation assessment and cannulation times, and patient pain scores.
Summary: Randomised trial 2023: handheld ultrasound guidance raised first-attempt cannulation success in difficult arteriovenous access from 72.0% to 96% and lowered pain scores (1.48 versus 2.13), with no increase in cannulation time
Result: First-attempt success was 96% with ultrasound guidance versus 72.0% with conventional cannulation (P = 0.049). Pain scores were lower with ultrasound guidance (1.48 ± 0.73 versus 2.13 ± 0.95; P = 0.012). Pre-cannulation assessment time and time spent on cannulation were comparable between groups. Nurses' confidence scores rose after training (26.6 ± 6.9 before versus 36.4 ± 3.0 after; P = 0.014).
Watch out: Fifty patients, one centre, and nurses newly trained in the technique — enthusiasm and training effects are entangled with the ultrasound effect itself, and the success difference rests on a P value of 0.049. No fistula survival or complication outcome was followed.
Source: Chen S, Liu JS, Chai CC, Si C, Tan SH, Ravindran HR, Martinez MTP, Gao Y et al.. Handheld ultrasound-guided cannulation of difficult hemodialysis arteriovenous access: A randomized controlled trial. Hemodial Int. 2023. PMID: 36281908. Registry ID: not stated in the record. MeSH: Humans · Renal Dialysis / methods · Kidney Failure, Chronic* · Arteriovenous Shunt, Surgical* · Catheterization / methods · Arteriovenous Fistula* · Ultrasonography, Interventional · Pain
Card 2 — Randomised trial 2021: ultrasound guidance cut additional needle passes (72 versus 99 events) and additional skin punctures (10 versus 25) across 346 cannulation events, but took longer and did not change pain scores
Study: Randomised controlled trial, event-randomised (32 participants; 346 cannulation events)
Population: Mixed-methods randomised clinical trial: 32 participants with difficult-to-cannulate arteriovenous fistulas had each cannulation event randomised to ultrasound guidance or standard technique — 346 events in total (170 ultrasound-guided, 176 standard). Outcomes were additional needle passes and skin punctures, time to achieve two-needle cannulation, pain, and local complications, with patient and staff questionnaires.
Summary: Randomised trial 2021: ultrasound guidance cut additional needle passes (72 versus 99 events) and additional skin punctures (10 versus 25) across 346 cannulation events, but took longer and did not change pain scores
Result: Ultrasound guidance significantly reduced additional needle passes (72 versus 99 events; P = 0.007) and additional skin punctures (10 versus 25; P = 0.016), but significantly prolonged the time to achieve two-needle cannulation. There was no difference in pain score (P = 0.705) or in complications between groups. Questionnaires showed the technique was acceptable to patients and staff. The authors note some excess time may reflect staff early in their learning curve.
Watch out: The unit of randomisation was the cannulation event, not the patient, so the 346 events come from only 32 fistulas and are not independent observations. Pain — the outcome patients feel — was unchanged here, contradicting the smaller trial carded above, and cannulation took longer.
Source: Eves J, Cai P, Latham R, Leung C, Carradice D, Chetter I, Smith G. A randomised clinical trial of ultrasound guided cannulation of difficult fistulae for dialysis access. J Vasc Access. 2021. PMID: 32883164. Registry ID: not stated in the record. MeSH: Arteriovenous Shunt, Surgical* / adverse effects · Catheterization / adverse effects · Humans · Renal Dialysis* · Ultrasonography · Ultrasonography, Interventional
Card 3 — Synthesis: two small randomised trials agree that ultrasound guidance makes difficult fistula cannulation more accurate — fewer attempts, passes and punctures — while disagreeing on pain, and neither measured whether access lasts longer
Study: Synthesis
Population: The carded record: two independent randomised trials (50 patients; 32 participants contributing 346 cannulation events); total documented N = 82 patients, additive.
Summary: Synthesis: two small randomised trials agree that ultrasound guidance makes difficult fistula cannulation more accurate — fewer attempts, passes and punctures — while disagreeing on pain, and neither measured whether access lasts longer
Result: Accuracy outcomes point the same way in both trials (first-attempt success 96% versus 72%; additional passes 72 versus 99 events). Pain improved in one trial and was unchanged in the other, and cannulation time was unchanged in one and prolonged in the other. With 82 patients in total and process endpoints only, the stamp is POSSIBLE (benefit) and Tier C despite two concordant trials — the two-trial gate for a higher stamp is not met on samples this small with no patency or complication follow-up.
Watch out: Both trials enrolled only difficult-to-cannulate fistulas; routine ultrasound for straightforward access is untested here. Cannulation technique comparisons (buttonhole versus stepladder) are a different question, homed on #1733, and access surveillance is on #9770.
Source: Synthesis of the carded records above (PMIDs 36281908, 32883164). Registry IDs: not stated in either record.