SourceMed · Shelf #11665 in the ask interface
Sharp-edged versus round-edged intraocular lenses: capsulotomy was rare at 1 year in both groups (1 versus 4 cases per 371 eyes), but by 3 and 5 years sharp edges were associated with about one-fifth the capsulotomy risk (risk ratio 0.21 relative at both time points) and consistently lower opacification scores, with no meaningful vision difference (Cochrane review, 10 studies, 1,065 people)
Shelf #11665 · Eyes, skin, nose & allergy
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
After cataract surgery, does implanting a sharp-edged rather than a round-edged intraocular lens reduce posterior capsule opacification and the need for laser capsulotomy?
Balance of the evidence
POSSIBLE (benefit) — Composition: a single Cochrane systematic review of 10 randomised studies (1,065 people, 1,834 eyes; 8 studies within-person, one eye sharp-edged and the fellow eye round-edged) — counted once from the synthesis, by people. The prespecified 1-year capsulotomy outcome was too rare to separate the designs (low-certainty); the separation appears at 2–5 years and in opacification scores (moderate-certainty). Vision differed trivially. Tier C is set for a single synthesis. This shelf is about optic edge design only; premium optic types (multifocal, trifocal and extended-depth-of-focus lenses) are held by shelves #4024 and #6930, and toric lenses by shelf #11668.
MeSH: Capsule Opacification / etiology · Capsule Opacification / prevention & control* · Cataract · Cataract Extraction* · Humans · Lens Capsule, Crystalline · Lens Implantation, Intraocular* · Lenses, Intraocular* · Phacoemulsification · Postoperative Complications / prevention & control* · Prosthesis Design*
Cards (2)
Card 1 — Cochrane 2021: at 1 year capsulotomy was too rare to judge (1 versus 4 cases), but at 3 and 5 years sharp-edged lenses carried about one-fifth the capsulotomy risk of round-edged lenses, with lower opacification scores throughout
Study: Systematic review of randomised controlled trials (10 studies, 1,065 people, 1,834 eyes)
Population: Cochrane systematic review: 10 randomised studies (1,065 people, 1,834 eyes) comparing sharp-edged with round-edged intraocular lenses after cataract surgery; 8 studies were within-person (one eye of each design). Lens materials were acrylic (2 studies), silicone (4), polymethyl methacrylate (3) and mixed (1). The prespecified primary outcome was the proportion of eyes having Nd:YAG laser capsulotomy at 1 year.
Summary: Cochrane 2021: at 1 year capsulotomy was too rare to judge (1 versus 4 cases), but at 3 and 5 years sharp-edged lenses carried about one-fifth the capsulotomy risk of round-edged lenses, with lower opacification scores throughout
Result: At 1 year, capsulotomy was rare in both groups (1 of 371 sharp-edged versus 4 of 371 round-edged eyes; Peto odds ratio 0.30 relative; 95% CI 0.05–1.74; low-certainty evidence — 7 fewer cases per 1,000 sharp-edged lenses, 95% CI 9 fewer to 7 more). At longer follow-up the difference firmed: capsulotomy risk ratio 0.35 relative at 2 years (703 eyes; 89 fewer per 1,000), 0.21 relative at 3 years (538 eyes; 170 fewer per 1,000) and 0.21 relative at 5 years (306 eyes; 331 fewer per 1,000). Every study reported lower opacification scores with sharp edges (about 0.5–3 units; moderate-certainty evidence). Visual acuity was slightly better with sharp edges at 1 year by an amount the reviewers call likely clinically unimportant (mean difference −0.06 logMAR; low-certainty). No study reported quality of life.
Watch out: Five of the 10 studies were at high risk of bias in at least one domain, most comparisons are within-person (both designs in the same patient, which suits an anatomical outcome but not patient-level outcomes), and the headline benefit is a reduction in a laser procedure years later — not better vision.
Source: Maedel S, Evans JR, Harrer-Seely A, Findl O. Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery. Cochrane Database Syst Rev. 2021. PMID: 34398965. Registry ID: not stated in the record. MeSH: Capsule Opacification / etiology · Capsule Opacification / prevention & control* · Cataract · Cataract Extraction* · Humans · Lens Capsule, Crystalline · Lens Implantation, Intraocular* · Lenses, Intraocular* · Phacoemulsification · Postoperative Complications / prevention & control* · Prosthesis Design*
Card 2 — Synthesis: sharp optic edges are associated with less capsule opacification and fewer capsulotomies from year 2 onward, at no vision cost — POSSIBLE (benefit) on a single Cochrane synthesis, Tier C
Study: Synthesis
Population: The carded record: one Cochrane review of 10 randomised studies (1,065 people, 1,834 eyes), counted once.
Summary: Synthesis: sharp optic edges are associated with less capsule opacification and fewer capsulotomies from year 2 onward, at no vision cost — POSSIBLE (benefit) on a single Cochrane synthesis, Tier C
Result: The direction is consistent across capsulotomy rates at 2, 3 and 5 years and across every opacification scoring system the studies used; the certainty is moderate for opacification and low for the 1-year primary outcome. That is a design-choice verdict, not a patient-outcome one: no quality-of-life data exist in the record.
Watch out: Edge design is only one PCO determinant; lens material comparisons are a separate question not carded on this shelf.
Source: Synthesis of the carded record above (PMID 34398965). Registry ID: not stated in the record.