Pulsed field ablation versus thermal ablation for paroxysmal atrial fibrillation (ADVENT)

Shelf #1171 · Heart, vessels, blood pressure & clotting

POSSIBLE

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does pulsed field ablation match conventional thermal (radiofrequency or cryoballoon) ablation on one-year freedom from atrial arrhythmia in paroxysmal atrial fibrillation, and with what safety profile?

Balance of the evidence

POSSIBLE: One randomised trial (ADVENT, 607 patients) found pulsed field ablation noninferior to thermal ablation for both its one-year efficacy composite (73.3% vs 71.3% free of events) and its serious device/procedure safety endpoint (2.1% vs 1.5%). A single pivotal trial caps the stamp at POSSIBLE. The wider pulsed-field literature is dominated by single-arm pivotal studies and registries, which is stated on the shelf face; the confirmatory randomised report sought at build could not be pinned to a verified record, so the shelf rests on ADVENT alone (see summary). No mortality claim is made.

MeSH: Atrial Fibrillation/classification,surgery · Bayes Theorem · Catheter Ablation/adverse effects,methods · Pulmonary Veins/surgery · Recurrence · Tachycardia/etiology

Cards (2)

Card 1 — ADVENT 2023: pulsed field ablation was noninferior to thermal ablation at 1 year — efficacy composite met in 73.3% vs 71.3%, safety events 2.1% vs 1.5%

Study: Randomised, single-blind, noninferiority trial

Population: 607 patients with drug-refractory paroxysmal atrial fibrillation assigned to pulsed field ablation (305) or conventional radiofrequency or cryoballoon ablation (302). The abstract does not state mean age or sex mix.

Summary: ADVENT (2023): pulsed field ablation was noninferior to thermal ablation at 1 year — efficacy composite met in 73.3% vs 71.3% .

Result: At 1 year the primary efficacy endpoint (freedom from initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation) was met in an estimated 73.3% with pulsed field ablation and 71.3% with thermal ablation (difference 2.0 percentage points; 95% Bayesian credible interval -5.2 to 9.2; posterior probability of noninferiority >0.999). Primary safety endpoint events (acute and chronic device- and procedure-related serious adverse events) occurred in an estimated 2.1% vs 1.5% (difference 0.6 points, -1.5 to 2.8; noninferiority probability >0.999).

Watch out: Noninferiority on a composite dominated by arrhythmia recurrence and repeat procedures is not superiority, and 1 year is short for ablation durability; the trial's 4-year report is a follow-up of this same trial, not a second trial.

Source: Reddy VY et al. Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation. The New England journal of medicine. 2023;389(18):1660-1671. PMID: 37634148. Registry ID: ClinicalTrials.gov NCT04612244, from the record's databank fields.

Card 2 — Synthesis: a new energy matches the old energies in its one randomised test — POSSIBLE

Study: Synthesis

Population: Synthesis of the card above: ADVENT (607 patients with paroxysmal atrial fibrillation).

Summary: Synthesis: a new energy matches the old energies in its one randomised test (the confirmatory PFA report remains unpinned, disclosed on the shelf) — POSSIBLE.

Result: ADVENT is the first randomised test of pulsed field (non-thermal electroporation) energy against thermal ablation, and it met noninferiority for efficacy (73.3% vs 71.3%) and safety (2.1% vs 1.5%) at 1 year. Catheter ablation versus drug therapy is home on Shelf #271 and ablation as first-line treatment on Shelf #712; neither is re-carded here — this shelf is the energy-versus-energy contest only.

Watch out: Single-trial shelf: purchasing and guideline decisions that treat pulsed field ablation as proven-equivalent across all AF populations run ahead of this one paroxysmal-AF trial.

Source: Synthesis of Reddy VY et al. N Engl J Med. 2023;389(18):1660-1671. PMID: 37634148. Registry ID as on the individual card.