SourceMed · Shelf #1178 in the ask interface

Inferior vena cava filters added to anticoagulation: PREPIC and PREPIC2

Shelf #1178 · Heart, vessels, blood pressure & clotting

LIKELY (the treatment made no difference for routine use)

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 1998–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does adding an inferior vena cava filter to anticoagulation prevent pulmonary embolism in patients with proximal deep-vein thrombosis or severe pulmonary embolism?

Balance of the evidence

LIKELY (the treatment made no difference for routine use): In PREPIC, a permanent filter cut pulmonary embolism at day 12 (1.1% vs 4.8%) but raised recurrent deep-vein thrombosis at 2 years (20.8% vs 11.6%) with no mortality difference; in PREPIC2, a retrievable filter added to anticoagulation in severe PE changed nothing (recurrent PE 3.0% vs 1.5% at 3 months, not significant). Mortality was null in both trials and no survival benefit is claimed, so the topic is not. The shelf's answer: filters are not a routine adjunct for patients who can be anticoagulated.

MeSH: Anticoagulants/adverse effects,therapeutic use · Combined Modality Therapy · Enoxaparin/adverse effects,therapeutic use · Hemorrhage/etiology · Heparin/adverse effects,therapeutic use · Pulmonary Embolism/etiology,mortality,prevention & control · Recurrence

Cards (3)

Card 1 — PREPIC 1998: a permanent vena cava filter cut early PE (1.1% vs 4.8% at day 12) but increased recurrent DVT by 2 years (20.8% vs 11.6%), with no mortality difference

Study: Randomised trial with two-by-two factorial design (filter vs no filter; low-molecular-weight vs unfractionated heparin)

Population: 400 patients with proximal deep-vein thrombosis at risk for pulmonary embolism, randomised to a vena caval filter (200) or no filter (200), and to enoxaparin (195) or unfractionated heparin (205). The abstract does not state mean age or sex mix.

Summary: PREPIC (1998): a permanent filter cut early PE ( 1.1% vs 4.8% at day 12) but increased recurrent DVT by 2 years (20.8% vs 11.6%).

Result: At day 12, symptomatic or asymptomatic pulmonary embolism had occurred in 2 patients (1.1%) assigned to filters vs 9 (4.8%) assigned to no filter (odds ratio 0.22; 95% CI 0.05 to 0.90 — a relative measure). At 2 years, recurrent deep-vein thrombosis had occurred in 37 filter patients (20.8%) vs 21 (11.6%) without (odds ratio 1.87, 1.10 to 3.20 — a relative measure inside the 0.5–2.0 caution band's edge). There were no significant differences in mortality or other outcomes. The heparin comparison likewise showed no significant difference in early PE (1.6% vs 4.2%; odds ratio 0.38, 0.10 to 1.38).

Watch out: A 1998 permanent-filter trial from the early low-molecular-weight-heparin era: its early-PE endpoint included asymptomatic events, and the filter's harm (more DVT) accrued over the full 2 years while its benefit was front-loaded into 12 days.

Source: Decousus H et al. A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis. Prévention du Risque d'Embolie Pulmonaire par Interruption Cave Study Group. The New England journal of medicine. 1998;338(7):409-15. PMID: 9459643. Registry ID: none in the record's databank fields — pre-registration-era trial (1998).

Card 2 — PREPIC2 2015: a retrievable filter added to anticoagulation did not reduce recurrent PE in severe PE/DVT (3.0% vs 1.5% at 3 months, P=0.50)

Study: Randomised, open-label, blinded-endpoint trial with 6-month follow-up

Population: 399 hospitalised patients with acute symptomatic pulmonary embolism associated with lower-limb vein thrombosis and at least one severity criterion, at 17 French centres; retrievable filter plus anticoagulation (n=200) or anticoagulation alone (n=199); the filter was successfully inserted in 193 and retrieved as planned in 153 of 164 attempts. The abstract does not state mean age.

Summary: PREPIC2 (2015): a retrievable filter added to anticoagulation did not reduce recurrent PE in severe PE/DVT ( 3.0% vs 1.5% at 3 months).

Result: By 3 months, symptomatic recurrent pulmonary embolism had occurred in 6 patients (3.0%; all fatal) in the filter group and 3 (1.5%; 2 fatal) in the control group (relative risk with filter 2.00; 95% CI 0.51 to 7.89; P=0.50) — a relative measure with absolute rates beside it, pointing the wrong way and not significant. Results were similar at 6 months, and no difference was seen in recurrent DVT, major bleeding, or death at 3 and 6 months (figures not separated in the abstract). Filter thrombosis occurred in 3 patients.

Watch out: The trial tests retrievable filters in patients who could all receive full anticoagulation; it says nothing about the classic filter indication — PE with an absolute contraindication to anticoagulation — where no randomised trial exists.

Source: Mismetti P et al. Effect of a retrievable inferior vena cava filter plus anticoagulation vs anticoagulation alone on risk of recurrent pulmonary embolism: a randomized clinical trial. JAMA. 2015;313(16):1627-35. PMID: 25919526. Registry ID: ClinicalTrials.gov NCT00457158, from the record's databank fields.

Card 3 — Synthesis: early mechanical protection, later venous harm, no survival gain — LIKELY the null for routine use

Study: Synthesis

Population: Synthesis of the cards above: PREPIC (400 patients, permanent filter) and PREPIC2 (399 patients, retrievable filter).

Summary: Synthesis: early mechanical protection, later venous harm, no survival gain — LIKELY the null for routine use.

Result: Seventeen years apart, the two randomised tests agree on the bottom line: in patients who can be anticoagulated, a vena cava filter does not improve net outcomes — PREPIC traded fewer early emboli (1.1% vs 4.8% at day 12) for more recurrent DVT (20.8% vs 11.6% at 2 years) with identical mortality, and PREPIC2 found no benefit at all (recurrent PE 3.0% vs 1.5%). Treatment of established PE is home on Shelves #237/#307; this shelf is the prevention-device question only.

Watch out: Both trials enrolled anticoagulable patients; the shelf must not be cited against filter use when anticoagulation is impossible.

Source: Synthesis of Decousus H et al. N Engl J Med. 1998;338(7):409-15. PMID: 9459643; Mismetti P et al. JAMA. 2015;313(16):1627-35. PMID: 25919526. Registry IDs as on the individual cards.