SourceMed · Shelf #11803 in the ask interface
Cough augmentation in neuromuscular disease: techniques raise peak cough flow against unassisted cough, but mechanical insufflation-exsufflation did not beat breath-stacking on chest infections, hospitalisation or survival in the one head-to-head trial (documented N = 287, counted once from the synthesis)
Shelf #11803 · Lungs, breathing & sleep
POSSIBLE (the treatment made no difference)
Stamped: 2026-11-28.
Evidence published: 2015–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people with neuromuscular disorders and a weak cough — including amyotrophic lateral sclerosis — does mechanical insufflation-exsufflation (a cough-assist device) clear secretions and reduce chest infections better than breath-stacking or other cough augmentation techniques?
Balance of the evidence
POSSIBLE (the treatment made no difference) — Composition: a Cochrane synthesis of cough augmentation techniques (11 studies, 287 adults and children) and, inside its era and eligibility, the one randomised head-to-head trial of mechanical insufflation-exsufflation (MI-E) versus breath-stacking in amyotrophic lateral sclerosis (40 patients). Total documented N = 287, counted once from the synthesis; the trial is not added. Between techniques, the synthesis found there may be little to no difference in peak cough flow, and the head-to-head trial found no significant difference in chest infections, antibiotic days, hospitalisation or survival — while techniques as a class may raise peak cough flow against unassisted cough, on very uncertain evidence. Neighbours: non-invasive ventilation in ALS is #2682 and diaphragm pacing added to it is #10026; this shelf is only about cough augmentation.
MeSH: Aged · Amyotrophic Lateral Sclerosis / complications · Amyotrophic Lateral Sclerosis / mortality · Amyotrophic Lateral Sclerosis / physiopathology · Amyotrophic Lateral Sclerosis / therapy* · Cough* · Female · Humans · Kaplan-Meier Estimate · Male · Middle Aged · Noninvasive Ventilation · Proportional Hazards Models · Respiratory Insufficiency / etiology · Respiratory Insufficiency / mortality · Respiratory Insufficiency / physiopathology · Respiratory Insufficiency / therapy* · Respiratory Therapy / instrumentation · Respiratory Therapy / methods* · Suction / instrumentation · Suction / methods* · Survival Rate · Treatment Outcome · Adolescent · Adult · Bias · Child · Child, Preschool · Chronic Disease · Cough / physiopathology* · Disease Progression · Hospitalization / statistics & numerical data* · Insufflation / methods · Mucociliary Clearance / physiology* · Neuromuscular Diseases / complications* · Patient Satisfaction · Quality of Life · Respiration · Respiration Disorders / etiology · Young Adult
Cards (3)
Card 1 — ALS trial 2015: MI-E versus breath-stacking — 19 versus 13 chest-infection episodes, 6 hospitalisations in each group, median survival 266 versus 535 days, none of it significant
Study: Randomised controlled trial (40 patients randomised)
Population: Preliminary randomised trial: 40 eligible patients with amyotrophic lateral sclerosis were randomised to breath-stacking with a lung-volume recruitment bag (21) or mechanical insufflator-exsufflator (19) and followed at 3-monthly intervals for at least 12 months or until death.
Summary: ALS trial 2015: MI-E versus breath-stacking — 19 versus 13 chest-infection episodes, 6 hospitalisations in each group, median survival 266 versus 535 days, none of it significant
Result: There were 13 episodes of chest infection in the breath-stacking group and 19 in the MI-E group (P = 0.92), requiring 90 and 95 days of antibiotics respectively (P = 0.34); mean symptom duration per infection was 6.9 versus 3.9 days (P = 0.16). Six hospitalisations occurred in each group. Median survival was 535 days on breath-stacking and 266 days on MI-E (P = 0.34), and quality of life was maintained above 75% of baseline for a median of 329 versus 205 days (P = 0.41). The authors concluded the trial was underpowered and recommended breath-stacking as the low-cost first-line technique pending a definitive trial.
Watch out: With 40 patients, the survival gap (535 versus 266 days) is exactly the kind of large-looking, non-significant difference a small trial produces by chance and confounding; it is printed here because the record prints it, not as evidence that the device shortens life.
Source: Rafiq MK, Bradburn M, Proctor AR, Billings CG et al.. A preliminary randomized trial of the mechanical insufflator-exsufflator versus breath-stacking technique in patients with amyotrophic lateral sclerosis. Amyotrophic lateral sclerosis & frontotemporal degeneration. 2015. PMID: 26140500. Registry ID: not stated in the record. MeSH: Aged · Amyotrophic Lateral Sclerosis / complications · Amyotrophic Lateral Sclerosis / mortality · Amyotrophic Lateral Sclerosis / physiopathology · Amyotrophic Lateral Sclerosis / therapy* · Cough* · Female · Humans · Kaplan-Meier Estimate · Male · Middle Aged · Noninvasive Ventilation · Proportional Hazards Models · Respiratory Insufficiency / etiology · Respiratory Insufficiency / mortality · Respiratory Insufficiency / physiopathology · Respiratory Insufficiency / therapy* · Respiratory Therapy / instrumentation · Respiratory Therapy / methods* · Suction / instrumentation · Suction / methods* · Survival Rate · Treatment Outcome
Card 2 — Cochrane 2021: cough augmentation techniques may raise peak cough flow versus unassisted cough (very uncertain evidence), with little to no difference between techniques and no study reporting the review's primary hospitalisation outcomes
Study: Systematic review of randomised trials (287 participants across 11 studies)
Population: Cochrane systematic review: 11 studies involving 287 adults and children aged 3 to 73 years with chronic neuromuscular disorders, comparing manually assisted cough, mechanical insufflation, breath-stacking, MI-E, glossopharyngeal breathing and combinations against unassisted cough, alternative techniques or sham. Searches ran to April 2020; certainty was assessed with GRADE.
Summary: Cochrane 2021: cough augmentation techniques may raise peak cough flow versus unassisted cough (very uncertain evidence), with little to no difference between techniques and no study reporting the review's primary hospitalisation outcomes
Result: No included study reported the review's primary outcomes (number and duration of unscheduled hospitalisations for acute respiratory exacerbations). A range of techniques may increase peak cough flow compared with unassisted cough (199 participants, 8 randomised trials), but the evidence is very uncertain; there may be little to no difference in peak cough flow between alternative techniques (216 participants, 9 trials). Evidence was insufficient for gas exchange, lung function, quality of life, function or satisfaction, and the reviewers were very uncertain about safety and efficacy overall.
Watch out: Most included studies were small cross-over physiology experiments measuring cough flow over minutes, not clinical trials measuring infections over months — the surrogate is plausible, but the clinical payoff is untested at any reasonable scale.
Source: Morrow B, Argent A, Zampoli M, Human A et al.. Cough augmentation techniques for people with chronic neuromuscular disorders. The Cochrane database of systematic reviews. 2021. PMID: 33887060. Registry ID: NCT01999075, NCT01518439, NCT04081116. MeSH: Adolescent · Adult · Aged · Bias · Child · Child, Preschool · Chronic Disease · Cough / physiopathology* · Disease Progression · Hospitalization / statistics & numerical data* · Humans · Insufflation / methods · Middle Aged · Mucociliary Clearance / physiology* · Neuromuscular Diseases / complications* · Patient Satisfaction · Quality of Life · Respiration · Respiration Disorders / etiology · Young Adult
Card 3 — Synthesis: cough augmentation probably helps a weak cough mechanically, but no technique — including the MI-E device — has been shown better than another, or better than none, on infections or admissions
Study: Synthesis
Population: The carded record: the Cochrane synthesis (287 participants, counted once) with the 40-patient ALS head-to-head trial sitting inside it; total documented N = 287.
Summary: Synthesis: cough augmentation probably helps a weak cough mechanically, but no technique — including the MI-E device — has been shown better than another, or better than none, on infections or admissions
Result: That supports POSSIBLE (the treatment made no difference) for the head-to-head device question at Tier C: the records overlap and count as one body of evidence.
Watch out: Absence of evidence here is not evidence of uselessness — clinicians use these techniques because the alternative for a patient who cannot cough is secretion retention — but purchasing or prioritising the device over the cheap bag technique has no trial support.
Source: Synthesis of the carded records above (PMIDs 26140500, 33887060). Registry IDs: NCT01999075, NCT01518439, NCT04081116 (registry numbers listed in the synthesis record for its included studies).