SourceMed · Shelf #11843 in the ask interface

Mesh versus suture for small umbilical hernia: recurrence 4% with mesh versus 12% with suture at up to 30 months in one double-blind multicentre trial (300 randomised; hazard ratio 0.31 relative; number needed to treat 12.8), with seroma, haematoma and wound infection each a little more frequent with mesh

Shelf #11843 · Liver & gut

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with a primary umbilical hernia of 1–4 cm, does mesh repair, compared with suture repair, reduce recurrence over about two years?

Balance of the evidence

POSSIBLE (benefit) — Composition: one randomised, double-blind, multicentre trial (300 patients randomised, 150 mesh and 150 suture, in 12 hospitals in the Netherlands, Germany and Italy) in adults with a primary umbilical hernia of 1–4 cm. Recurrence by a maximum of 30 months was lower with mesh: six recurrences (4%) in 146 assessed patients versus 17 (12%) in 138 (hazard ratio 0.31 relative, 95% CI 0.12 to 0.80; P = 0.01; number needed to treat 12.8). The trade-off printed on the face: seroma (3% mesh versus under 1% suture), haematoma (2% versus 1%) and wound infection (2% versus under 1%) were each slightly more frequent with mesh, and there were no anaesthetic complications or postoperative deaths. The stamp is Tier C: a single trial, however well conducted, and follow-up is a median of 25.1 months — late mesh complications and very late recurrence are outside this record. The record does not name a specific mesh product or manufacturer, and this pack states that plainly rather than guessing one. Neighbouring hernia questions live elsewhere: laparoscopic versus open inguinal hernia repair is on shelf #11461, prophylactic mesh at laparotomy closure (PRIMA) is on shelf #2589, and prophylactic mesh at end colostomy is on shelf #6422.

MeSH: Adult · Aged · Double-Blind Method · Female · Germany / epidemiology · Hernia, Umbilical / surgery* · Humans · Italy / epidemiology · Male · Middle Aged · Netherlands / epidemiology · Outcome Assessment, Health Care · Postoperative Complications / epidemiology · Quality of Life · Recurrence · Surgical Mesh / adverse effects* · Surgical Mesh / standards · Suture Techniques / adverse effects* · Suture Techniques / standards · Sutures / adverse effects* · Sutures / standards

Cards (2)

Card 1 — Double-blind multicentre trial (300 randomised): umbilical hernia recurrence 4% after mesh versus 12% after suture repair — hazard ratio 0.31 relative, number needed to treat 12.8

Study: Randomised controlled trial, double-blind, multicentre (300 patients randomised)

Population: Randomised, double-blind, controlled multicentre trial in 12 hospitals (nine in the Netherlands, two in Germany, one in Italy): adults aged at least 18 years with a primary umbilical hernia of diameter 1–4 cm, randomly assigned intra-operatively 1:1 to suture repair or mesh repair (150 each), stratified by hernia size (1–2 cm and over 2–4 cm), with patients, investigators and analysts masked. Follow-up examinations at 2 weeks and 3, 12 and 24–30 months; median follow-up 25.1 months. The primary outcome was recurrence at 24 months in the modified intention-to-treat population. The record does not name a specific mesh product or manufacturer.

Summary: Double-blind multicentre trial (300 randomised): umbilical hernia recurrence 4% after mesh versus 12% after suture repair — hazard ratio 0.31 relative, number needed to treat 12.8

Result: After a maximum follow-up of 30 months there were fewer recurrences in the mesh group than the suture group: six (4%) in 146 patients versus 17 (12%) in 138 patients; 2-year actuarial recurrence estimates 3.6% (95% CI 1.4 to 9.4) versus 11.4% (6.8 to 18.9); hazard ratio 0.31 relative (95% CI 0.12 to 0.80); P = 0.01; number needed to treat 12.8. The most common postoperative complications were seroma (one patient, under 1%, suture versus five, 3%, mesh), haematoma (two, 1%, versus three, 2%) and wound infection (one, under 1%, versus three, 2%). There were no anaesthetic complications or postoperative deaths.

Watch out: One trial, and follow-up centred on two years: mesh infection, chronic pain and recurrence beyond 30 months are not answered here. The trial covers primary hernias of 1–4 cm in adults — recurrent, incarcerated and larger hernias, and repair during another operation, are outside it.

Source: Kaufmann R, Halm JA, Eker HH et al.. Mesh versus suture repair of umbilical hernia in adults: a randomised, double-blind, controlled, multicentre trial. Lancet. 2018. PMID: 29459021. Registry ID: NCT00789230. MeSH: Adult · Aged · Double-Blind Method · Female · Germany / epidemiology · Hernia, Umbilical / surgery* · Humans · Italy / epidemiology · Male · Middle Aged · Netherlands / epidemiology · Outcome Assessment, Health Care · Postoperative Complications / epidemiology · Quality of Life · Recurrence · Surgical Mesh / adverse effects* · Surgical Mesh / standards · Suture Techniques / adverse effects* · Suture Techniques / standards · Sutures / adverse effects* · Sutures / standards

Card 2 — Synthesis: one well-masked multicentre trial — mesh roughly thirds recurrence for small umbilical hernias, at the price of slightly more seroma, haematoma and wound infection

Study: Synthesis

Population: The carded record: one randomised double-blind multicentre trial (300 patients randomised; 284 assessed for the recurrence outcome); total documented N = 300 randomised.

Summary: Synthesis: one well-masked multicentre trial — mesh roughly thirds recurrence for small umbilical hernias, at the price of slightly more seroma, haematoma and wound infection

Result: Recurrence 4% versus 12% (hazard ratio 0.31 relative); minor wound complications each ran 1–2 percentage points higher with mesh. POSSIBLE (benefit), Tier C: a single trial cannot carry a stronger stamp under the two-trial gate, whatever its quality.

Watch out: Whether the recurrence advantage persists at five and ten years, and the long-term behaviour of mesh in this position, are outside this record.