FOCUS harmonic scalpel versus clamp-and-tie in total thyroidectomy: transient recurrent laryngeal nerve palsy 3.99% with the device versus 5.23% conventional (relative risk 0.79 relative) and transient hypocalcaemia 11.3% versus 15.4%, across 43 randomised trials (10,361 patients) in one meta-analysis
Shelf #11847 · Thyroid & parathyroid
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients having total thyroidectomy, does the FOCUS harmonic scalpel (an ultrasonic vessel-sealing device), compared with the conventional clamp-and-tie technique, reduce recurrent laryngeal nerve palsy, hypocalcaemia and bleeding?
Balance of the evidence
POSSIBLE (benefit) — Composition: one systematic review and meta-analysis of 43 randomised controlled trials (10,361 patients) comparing total thyroidectomy performed with the second-generation FOCUS harmonic scalpel — the specific ultrasonic device tested, named here because the evidence is device-specific — against the conventional clamp-and-tie technique. Transient recurrent laryngeal nerve palsy was less frequent with the device: 3.99% versus 5.23% (relative risk 0.79 relative, 95% CI 0.63 to 0.99). Transient hypocalcaemia was reported in 11.3% of device patients versus 15.4% of clamp-and-tie patients. The reviewers attribute the differences to less thermal damage to nerves and parathyroid glands and also report lower rates of postoperative bleeding and cervical haematoma, outcomes for which their abstract gives no figures — so no figures are printed for them here. The stamp is Tier C: a single synthesis, however large, and its two quantified advantages are in transient complications; permanent nerve palsy and permanent hypocalcaemia are not quantified in the record. The record names the device (FOCUS harmonic scalpel) but does not name its manufacturer, and this pack states that plainly rather than supplying one. Neighbouring questions live elsewhere: drains after thyroid surgery are on shelf #11839 in this block, and intra-operative nerve monitoring is a separate question (a targeted gate search found it cross-pointed on shelf #6922's face, not owned as a thyroid shelf).
MeSH: Humans · Ligation / instrumentation · Randomized Controlled Trials as Topic · Surgical Instruments · Thyroidectomy* / adverse effects · Thyroidectomy* / instrumentation · Thyroidectomy* / methods · Ultrasonic Surgical Procedures* / instrumentation
Cards (2)
Card 1 — Meta-analysis of 43 randomised trials (10,361 patients): transient nerve palsy 3.99% with the FOCUS harmonic scalpel versus 5.23% with clamp-and-tie (relative risk 0.79 relative); transient hypocalcaemia 11.3% versus 15.4%
Study: Systematic review and meta-analysis of randomised controlled trials (43 trials, 10,361 patients)
Population: Systematic review and meta-analysis of randomised controlled trials of total thyroidectomy comparing the sutureless FOCUS harmonic scalpel (a second-generation ultrasonic energy-based device; the record names the device and does not name its manufacturer) with the conventional clamp-and-tie technique: 43 trials, 10,361 patients — described by the authors as the largest such comparison in the literature.
Summary: Meta-analysis of 43 randomised trials (10,361 patients): transient nerve palsy 3.99% with the FOCUS harmonic scalpel versus 5.23% with clamp-and-tie (relative risk 0.79 relative); transient hypocalcaemia 11.3% versus 15.4%
Result: The incidence of transient recurrent laryngeal nerve palsy was statistically lower with the ultrasonic device: 3.99% versus 5.23% (relative risk 0.79 relative, 95% CI 0.63 to 0.99). Transient hypocalcaemia occurred in 11.3% of patients operated on with the device and 15.4% of those operated on with clamp-and-tie. The authors conclude the sutureless device is associated with a lower risk of damage to the laryngeal nerves and parathyroid glands, attributing this to less thermal damage, and report that it can also diminish postoperative bleeding and cervical haematoma — outcomes for which the record's abstract prints no rates, so none are given here.
Watch out: Both quantified advantages are in transient complications; the abstract does not quantify permanent recurrent laryngeal nerve palsy or permanent hypocalcaemia, the outcomes patients weigh most. A single synthesis of many small trials is also exposed to small-study and publication effects, and the device comparison is specific to this instrument — other energy devices are not what these 43 trials tested.
Source: Cirocchi R, Matteucci M, Lori E et al.. Sutureless FOCUS harmonic scalpel versus clamp-and-tie techniques for thyroidectomy: a meta-analysis of 43 randomized controlled trials. International journal of surgery. 2024. PMID: 39806747. Registry ID: not stated in the record. MeSH: Humans · Thyroidectomy* / methods · Thyroidectomy* / instrumentation · Thyroidectomy* / adverse effects · Randomized Controlled Trials as Topic · Ultrasonic Surgical Procedures* / instrumentation · Surgical Instruments · Ligation / instrumentation
Card 2 — Synthesis: one large meta-analysis — the FOCUS device shows fewer transient nerve palsies and less transient hypocalcaemia than clamp-and-tie; permanent outcomes are not quantified in the record
Study: Synthesis
Population: The carded record: one systematic review and meta-analysis (43 randomised trials, 10,361 patients); total documented N = 10,361, counted once from the synthesis.
Summary: Synthesis: one large meta-analysis — the FOCUS device shows fewer transient nerve palsies and less transient hypocalcaemia than clamp-and-tie; permanent outcomes are not quantified in the record
Result: Transient recurrent laryngeal nerve palsy 3.99% versus 5.23% (relative risk 0.79 relative, 95% CI 0.63 to 0.99); transient hypocalcaemia 11.3% versus 15.4%. POSSIBLE (benefit), Tier C: a single synthesis, and the benefit as documented is confined to transient events.
Watch out: Cost, operating time and length of stay are not quantified in the carded record's abstract and are not claimed on this shelf; hemithyroidectomy and other energy devices are outside the tested comparison.
Source: Synthesis of the carded records above (PMIDs 39806747). Registry IDs: not stated in the record.