SourceMed · Shelf #11873 in the ask interface

Point-of-care ultrasound for undifferentiated hypotension (SHoC-ED): survival 104 of 136 with ultrasound versus 102 of 134 without — and no difference in CT use, fluids, inotropes or length of stay — in the one randomised trial (documented N = 273 randomised, counted once across both reports)

Shelf #11873 · Emergency & first hours

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2018–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In emergency-department patients with undifferentiated hypotension, does adding an early point-of-care ultrasonography protocol to standard care improve survival, change the treatment delivered, or sharpen diagnostic accuracy, compared with standard care without ultrasonography?

Balance of the evidence

POSSIBLE (the treatment made no difference) — Composition: one international multicentre randomised trial (273 patients randomised, 270 with follow-up), carded twice — the outcomes report and the diagnostic-accuracy report of the same trial; total documented N = 273, counted once. Survival was 104 of 136 with the ultrasound protocol versus 102 of 134 with standard care (difference 0.35%; 95% CI −10.2% to 11.0%), with no important differences in CT scanning, intravenous fluids, inotrope use or length of stay, and diagnostic accuracy for cardiogenic shock was essentially the same with and without the protocol (overall accuracy 93.7% versus 93.6%). The stamp is POSSIBLE and Tier C: a single trial, and its interval cannot exclude a survival difference of about 10 points in either direction. Neighbouring ultrasound questions are homed elsewhere: lung ultrasound for pneumonia is shelf #3875, for pulmonary oedema shelf #8661, FAST accuracy in trauma shelf #8660, and inferior-vena-cava ultrasound against central venous pressure shelf #8416; this shelf answers only whether a protocolised ultrasound examination changes outcomes in undifferentiated hypotension.

MeSH: Clinical Protocols* · Emergency Service, Hospital · Female · Humans · Hypotension / diagnosis* · Hypotension / diagnostic imaging · Hypotension / mortality · Hypotension* / diagnostic imaging · Male · Middle Aged · North America · Point-of-Care Systems · Point-of-Care Systems / statistics & numerical data* · Quality Improvement · Shock* / diagnostic imaging · Shock, Cardiogenic · South Africa · Ultrasonography / methods · Ultrasonography / statistics & numerical data*

Cards (3)

Card 1 — SHoC-ED 2018 RCT: adding a point-of-care ultrasound protocol to standard care did not improve survival (104 of 136 versus 102 of 134) or change CT use, fluids, inotropes or stay

Study: Randomised controlled trial, international multicentre (273 patients randomised; 270 followed up)

Population: International multicentre randomised trial at 6 centres in North America and South Africa: 273 emergency-department patients with undifferentiated hypotension (systolic blood pressure under 100 mm Hg or shock index over 1) randomised to early point-of-care ultrasonography plus standard care or standard care without ultrasonography; follow-up was completed for 270 (136 ultrasound, 134 control). The primary outcome was survival to 30 days or hospital discharge; over half the patients had occult sepsis as the final diagnosis.

Summary: SHoC-ED 2018 RCT: adding a point-of-care ultrasound protocol to standard care did not improve survival (104 of 136 versus 102 of 134) or change CT use, fluids, inotropes or stay

Result: Survival: 104 of 136 (ultrasound) versus 102 of 134 (standard care) — difference 0.35% (95% CI −10.2% to 11.0%). Survival also did not differ within North America (76 of 89 versus 72 of 88) or South Africa (28 of 47 versus 30 of 46). There were no important differences in rates of CT scanning, inotrope or intravenous fluid use, or intensive-care or total length of stay.

Watch out: The confidence interval is wide (−10.2% to +11.0%): the trial rules out a large survival benefit, not a moderate one. Most patients turned out to have occult sepsis — a group in which a structural ultrasound protocol has the least to add.

Source: Atkinson PR, Milne J, Diegelmann L et al.. Does Point-of-Care Ultrasonography Improve Clinical Outcomes in Emergency Department Patients With Undifferentiated Hypotension? An International Randomized Controlled Trial From the SHoC-ED Investigators. Ann Emerg Med. 2018. PMID: 29866583. Registry ID: NCT01419106. MeSH: Clinical Protocols* · Emergency Service, Hospital · Female · Humans · Hypotension / diagnosis* · Hypotension / diagnostic imaging · Hypotension / mortality · Male · Middle Aged · North America · Point-of-Care Systems / statistics & numerical data* · Quality Improvement · South Africa · Ultrasonography / statistics & numerical data*

Card 2 — SHoC-ED diagnostic report 2023: the ultrasound protocol performed well but no better than standard assessment for telling cardiogenic from non-cardiogenic shock (overall accuracy 93.7% versus 93.6%; specificity 95.5% versus 93.8%)

Study: Randomised controlled trial, diagnostic-accuracy report (same 273 patients as the card above)

Population: Diagnostic-accuracy report of the same SHoC-ED trial carded above (same 273 randomised patients, 270 with follow-up; not added to the pack total). Initial and 60-minute diagnoses in the ultrasound and control groups were compared with the final diagnosis, concentrating on cardiogenic versus non-cardiogenic shock.

Summary: SHoC-ED diagnostic report 2023: the ultrasound protocol performed well but no better than standard assessment for telling cardiogenic from non-cardiogenic shock (overall accuracy 93.7% versus 93.6%; specificity 95.5% versus 93.8%)

Result: For cardiogenic shock, specificity was 95.5% (95% CI 89.9–98.5) with the ultrasound approach versus 93.8% (87.7–97.5) with standard assessment; positive likelihood ratio 17.92 versus 14.80, negative likelihood ratio 0.21 versus 0.09, diagnostic odds ratio 85.6 versus 166.57, and overall diagnostic accuracy 93.7% versus 93.6%. Performance was similar across shock subcategories: the protocol worked well as a rule-in test but did not meaningfully beat standard assessment.

Watch out: Same patients as the outcomes report — this is one trial read two ways, not corroboration. The negative likelihood ratio actually favoured standard assessment (0.09 versus 0.21), so the protocol's edge, if any, is in ruling shock types in, not out.

Source: Peach M, Milne J, Diegelmann L et al.. Does point-of-care ultrasonography improve diagnostic accuracy in emergency department patients with undifferentiated hypotension? An international randomized controlled trial from the SHOC-ED investigators. CJEM. 2023. PMID: 36577931. Registry ID: not stated in the record. MeSH: Humans · Point-of-Care Systems · Ultrasonography / methods · Hypotension* / diagnostic imaging · Shock* / diagnostic imaging · Emergency Service, Hospital · Shock, Cardiogenic

Card 3 — Synthesis: one randomised trial finds a protocolised ultrasound examination in undifferentiated hypotension changes neither survival nor the care delivered, and adds no diagnostic accuracy over standard assessment

Study: Synthesis

Population: The carded record: the SHoC-ED trial in two reports; total documented N = 273 randomised, counted once.

Summary: Synthesis: one randomised trial finds a protocolised ultrasound examination in undifferentiated hypotension changes neither survival nor the care delivered, and adds no diagnostic accuracy over standard assessment

Result: A coherent null across outcomes, process measures and accuracy. Single trial, wide survival interval — POSSIBLE (the treatment made no difference). The finding is about the protocol as tested, not about targeted ultrasound questions (a suspected tamponade or aneurysm), which sit on their own shelves.

Watch out: Clinicians in the trial could still obtain formal imaging in both arms; the comparison is protocolised bedside ultrasound added early, not ultrasound versus no imaging ever.

Source: Synthesis of the carded records above (PMIDs 29866583, 36577931). Registry ID: NCT01419106 (stated in the 2018 record; the 2023 record states none).