SourceMed · Shelf #11922 in the ask interface

Volar locking plate versus Kirschner wires for distal radius fractures needing fixation (DRAFFT, 461 patients): wrist scores identical at 12 months (PRWE difference −1.3), complications equal, wires £727 cheaper per patient (documented N = 461)

Shelf #11922 · Bones & joints

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with a dorsally displaced distal radius fracture judged to need surgical fixation, does volar locking-plate fixation give better wrist function than percutaneous Kirschner-wire fixation?

Balance of the evidence

POSSIBLE (the treatment made no difference) — in DRAFFT (461 patients, 18 UK centres), volar locking-plate fixation and Kirschner-wire fixation produced the same wrist function at 3, 6 and 12 months (Patient-Rated Wrist Evaluation difference at 12 months −1.3, 95% CI −4.5 to 1.8), the same number of complications, and near-identical quality-adjusted life-years, while wire fixation saved £727 per patient. Tier C because this is one trial programme (the second card is its economic analysis, not an independent trial). Boundary: this shelf compares two operations in fractures already judged to need fixation. Whether surgery beats a cast at all is pack #3762, which cards DRAFFT2 and CROSSFIRE; it is cross-pointed, not re-carded.

MeSH: Bone Plates* · Bone Wires* · Female · Fractures, Bone / economics · Fractures, Bone / surgery* · Humans · Male · Quality-Adjusted Life Years · Radius* · Single-Blind Method · United Kingdom · Cost-Benefit Analysis · Fracture Fixation, Internal / economics* · Fracture Fixation, Internal / instrumentation* · Length of Stay / statistics & numerical data · Palmar Plate / surgery* · Radius Fractures / surgery* · State Medicine

Cards (3)

Card 1 — DRAFFT (461 patients, 2015): volar locking-plate fixation gave no better wrist function than Kirschner-wire fixation at 3, 6 or 12 months (PRWE difference −1.3 at 12 months), with no difference in complications — and wires cost less

Study: Randomised controlled trial (461 patients randomised)

Population: UK multicentre randomised trial (18 trauma centres): 461 adults having surgery for an acute dorsally displaced distal radius fracture randomised to percutaneous Kirschner-wire fixation or volar locking-plate fixation. The primary outcome was the Patient-Rated Wrist Evaluation (PRWE) at 12 months; neither patients nor surgeons could be blinded. Over 90% completed follow-up.

Summary: DRAFFT (461 patients, 2015): volar locking-plate fixation gave no better wrist function than Kirschner-wire fixation at 3, 6 or 12 months (PRWE difference −1.3 at 12 months), with no difference in complications — and wires cost less

Result: Both groups recovered wrist function by 12 months, with no clinically relevant difference in PRWE at 3, 6 or 12 months (difference at 12 months −1.3, 95% CI −4.5 to 1.8; P = 0.398). There was no difference in the number of complications. Kirschner-wire fixation was cost-saving (−£727, 95% CI −£588 to −£865) with a small quality-adjusted life-year difference (0.008, 95% CI −0.001 to 0.018) favouring plates.

Watch out: Only dorsally displaced fractures judged to need surgery were enrolled; fractures suitable for a cast alone are the separate question on pack #3762.

Source: Costa ML, Achten J, Plant C et al.. UK DRAFFT: a randomised controlled trial of percutaneous fixation with Kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius. Health Technol Assess. 2015. PMID: 25716883. Registry ID: ISRCTN31379280, stated in the record. MeSH: Bone Plates* · Bone Wires* · Female · Fractures, Bone / economics · Fractures, Bone / surgery* · Humans · Male · Quality-Adjusted Life Years · Radius* · Single-Blind Method · United Kingdom

Estimate type: adjusted estimate, as stated in the card.

Card 2 — DRAFFT economic analysis (460 patients analysed, 2015): locking plates cost £714 more per patient for a negligible quality-adjusted life-year gain — an incremental cost-effectiveness ratio of £89,322 per QALY

Study: Cost-effectiveness analysis of a randomised trial (460 patients analysed)

Population: Cost-effectiveness analysis of the DRAFFT trial above (same patients; no patient is counted twice in this pack's total): costs from an NHS perspective (surgery, implants, healthcare use over 12 months) and a societal perspective (time off work, private care), in 460 patients with data available.

Summary: DRAFFT economic analysis (460 patients analysed, 2015): locking plates cost £714 more per patient for a negligible quality-adjusted life-year gain — an incremental cost-effectiveness ratio of £89,322 per QALY

Result: Locking-plate fixation cost a mean of £714 more per patient (95% CI 588 to 865) than Kirschner-wire fixation for only a small difference in quality-adjusted life-years gained, giving an incremental cost-effectiveness ratio of £89,322 per quality-adjusted life-year in the first 12 months; sensitivity analyses all exceeded £30,000 per quality-adjusted life-year. The authors conclude wire fixation is cost-saving with similar health benefits.

Watch out: Costs are 2015 UK NHS figures; the clinical equivalence comes from the trial card above, not from this analysis.

Source: Tubeuf S, Yu G, Achten J et al.. Cost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: analysis from the DRAFFT trial. Bone Joint J. 2015. PMID: 26224825. Registry ID: none stated in the record. MeSH: Bone Plates* · Bone Wires* · Cost-Benefit Analysis · Female · Fracture Fixation, Internal / economics* · Fracture Fixation, Internal / instrumentation* · Humans · Length of Stay / statistics & numerical data · Male · Palmar Plate / surgery* · Quality-Adjusted Life Years · Radius Fractures / surgery* · State Medicine

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Synthesis: for a dorsally displaced distal radius fracture that needs fixation, wires and volar locking plates end in the same place at 1 year — wires are quicker and cheaper

Study: Synthesis

Population: The carded record: the DRAFFT randomised trial (461 patients randomised) and its economic analysis; total documented N = 461, counted once.

Summary: Synthesis: for a dorsally displaced distal radius fracture that needs fixation, wires and volar locking plates end in the same place at 1 year — wires are quicker and cheaper

Result: Function, complications and quality of life did not differ between the two fixations at any point to 12 months; the plate's extra cost bought no measurable health gain. This shelf answers only plate versus wires among patients already judged to need surgery: whether to operate at all versus a cast is pack #3762 (DRAFFT2 and CROSSFIRE), cross-pointed here and not re-carded.

Watch out: Surgeon preference and fracture patterns needing a plate for stability (for example intra-articular or volar-displaced fractures) are outside this trial's dorsally displaced, surgery-judged population.

Source: Synthesis of the carded records above (PMIDs 25716883, 26224825). Registry ID: ISRCTN31379280.