Hip replacement implant combinations (network meta-analysis of randomised trials, 3,177 hips): nothing beat the reference cemented metal-on-polyethylene small-head implant on revision or Harris hip score; metal-on-metal (hazard ratio 4.4 relative) and resurfacing (12.1 relative) revised more (documented N = 3,177 hips)
Shelf #11926 · Bones & joints
POSSIBLE (the treatment made no difference)
Stamped: 2026-11-28.
Evidence published: 2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults having primary total hip replacement, do newer implant combinations — ceramic or metal bearings, large heads, uncemented or hybrid fixation — reduce revision or improve function compared with the reference cemented metal-on-polyethylene small-head implant?
Balance of the evidence
POSSIBLE (the treatment made no difference) — in the BMJ network meta-analysis of randomised trials (15 studies, 3,177 hips for revision; 31 studies, 2,888 patients for Harris hip score, overlapping sets), no bearing-surface, head-size or fixation combination reduced revision or improved hip score compared with the reference implant: cemented, metal-on-polyethylene (not highly cross-linked), small head. Two combinations were worse at 0–2 years: metal-on-metal small-head cemented (hazard ratio 4.4 relative) and resurfacing (hazard ratio 12.1 relative), both imprecisely estimated. Tier C: a single network synthesis of small, poorly reported trials — absence of evidence for the newer combinations, printed as such, not proof of equivalence. Approach (anterior versus posterior) is pack #10318 and cemented versus uncemented hemiarthroplasty for fracture is pack #3727; both cross-pointed, not re-carded.
MeSH: Adult · Aged · Arthroplasty, Replacement, Hip / instrumentation* · Ceramics · Female · Hip Prosthesis* · Humans · Male · Metal-on-Metal Joint Prostheses · Middle Aged · Polyethylenes · Prosthesis Failure* · Randomized Controlled Trials as Topic · Reoperation / statistics & numerical data* · Treatment Outcome
Cards (2)
Card 1 — BMJ network meta-analysis (2017): no implant combination — bearing surface, head size or fixation — beat the reference cemented metal-on-polyethylene small-head hip replacement on revision or hip score; metal-on-metal and resurfacing were worse
Study: Systematic review and network meta-analysis of randomised trials (3,177 hips in the revision network)
Population: Systematic review and network meta-analysis of randomised trials of primary total hip replacement, comparing implant combinations defined by bearing surface (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic, metal-on-metal), head size (large, 36 mm or more, or small, under 36 mm) and fixation (cemented, uncemented, hybrid, reverse hybrid). The reference combination was metal-on-polyethylene (not highly cross-linked), small head, cemented. Seventy-seven studies were included in the review; 15 studies (3,177 hips) entered the revision network meta-analysis and 31 studies (2,888 patients) the Harris hip score analysis. The two analysis sets overlap and are not added together.
Summary: BMJ network meta-analysis (2017): no implant combination — bearing surface, head size or fixation — beat the reference cemented metal-on-polyethylene small-head hip replacement on revision or hip score; metal-on-metal and resurfacing were worse
Result: There was no evidence that any other combination reduced revision risk compared with the reference at 0–2 or 2–10 years, and no combination had a better Harris hip score. Metal-on-metal, small-head, cemented implants increased revision risk at 0–2 years (hazard ratio 4.4 relative, 95% credible interval 1.6 to 16.6), as did resurfacing (hazard ratio 12.1 relative, 95% credible interval 2.1 to 120.3); estimates were imprecise and reporting across studies was poor.
Watch out: A network of mostly small, poorly reported trials: 'no evidence of benefit' for newer combinations is not proof of equivalence, and highly cross-linked polyethylene — now standard — was the reference's older comparator.
Source: López-López JA, Humphriss RL, Beswick AD et al.. Choice of implant combinations in total hip replacement: systematic review and network meta-analysis. BMJ. 2017. PMID: 29097396. Registry ID: PROSPERO CRD42015019435, stated in the record (systematic review registration). MeSH: Adult · Aged · Arthroplasty, Replacement, Hip / instrumentation* · Ceramics · Female · Hip Prosthesis* · Humans · Male · Metal-on-Metal Joint Prostheses · Middle Aged · Polyethylenes · Prosthesis Failure* · Randomized Controlled Trials as Topic · Reoperation / statistics & numerical data* · Treatment Outcome
Card 2 — Synthesis: within randomised evidence, the old reference hip — cemented, metal-on-polyethylene, small head — was not beaten by any newer bearing, head-size or fixation combination
Study: Synthesis
Population: The carded record: the BMJ network meta-analysis only; total documented N = 3,177 hips in the revision network (the 2,888-patient hip-score set overlaps and is not added).
Summary: Synthesis: within randomised evidence, the old reference hip — cemented, metal-on-polyethylene, small head — was not beaten by any newer bearing, head-size or fixation combination
Result: The practical content is negative and positive at once: nothing newer proved better on revision or clinician-rated function, and two options proved worse early (metal-on-metal small-head cemented, and resurfacing). This shelf is about implant choice in primary replacement for osteoarthritis-type practice; replacement versus training is pack #11923 (PROHIP) and replacement for fracture is pack #11570 — neither is re-carded here.
Watch out: Registry (non-randomised) evidence on modern combinations is far larger than this trial network; the stamp covers only what randomised comparisons show.
Source: Synthesis of the carded record above (PMID 29097396). Registry ID: PROSPERO CRD42015019435.