SourceMed · Shelf #11941 in the ask interface

Early discharge after transfemoral TAVI (FAST-TAVI): a criteria-based prospective registry (502 patients) recorded 30-day mortality of 1.1% and fewer complications in patients appropriately discharged early; the cluster-randomised FAST-TAVI II trial (1,829 patients) raised discharge within 3 days from 42.3% to 58.1% and cut median stay from 4 to 3 days, with similar 30-day mortality and readmission (documented N = 2,331)

Shelf #11941 · Heart, vessels, blood pressure & clotting

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 2019–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

After transfemoral transcatheter aortic valve implantation, does a criteria-based early-discharge pathway shorten hospital stay without increasing 30-day complications, death or readmission?

Balance of the evidence

POSSIBLE (benefit) — Composition: one prospective multicentre registry validating prespecified discharge criteria (502 patients) and one multicentre cluster-randomised trial of a training programme implementing 10 quality-of-care measures (1,829 patients); independent cohorts, additive (total documented N = 2,331). The benefit claimed is a pathway benefit — more patients home within 3 days and a shorter stay — at no detected cost in 30-day safety: in FAST-TAVI II, early discharge rose from 42.3% to 58.1% (P < 0.0001) and median stay fell from 4 to 3 days, with 30-day mortality 0.5% versus 0.9% (P = 0.30) and 30-day readmission 4.6% versus 2.8% (P = 0.28; numerically higher in the intervention group, not significant). In the registry, the 30-day composite of death, vascular complications, pacemaker implantation, stroke, cardiac rehospitalisation, kidney failure and major bleeding was 12.9% overall and was lower in patients appropriately discharged early (7.0% versus 26.4%) — a comparison confounded by the fact that the criteria select lower-risk patients, stated on the card. This shelf answers the discharge-pathway question only: whether TAVI beats surgery is owned at ask #266, valve-type comparisons are on shelf #10347, and early intervention in asymptomatic severe aortic stenosis is on shelf #1629.

MeSH: Aortic Valve · Aortic Valve Stenosis · Europe · Humans · Patient Discharge · Prospective Studies · Registries · Risk Factors · Transcatheter Aortic Valve Replacement · Treatment Outcome · Aged · Aged, 80 and over · Aortic Valve Stenosis / surgery · Length of Stay · Aortic Valve / surgery

Cards (3)

Card 1 — FAST-TAVI registry 2019: prespecified discharge criteria validated in 502 patients — 30-day mortality 1.1%, composite complications 12.9%

Study: Prospective multicentre registry (502 patients enrolled)

Population: Prospective European multicentre registry: 502 unselected patients undergoing transfemoral transcatheter aortic valve implantation at 10 sites in three countries, discharged according to a prespecified set of risk criteria. The primary endpoint was the composite of all-cause mortality, vascular access-related complications, permanent pacemaker implantation, stroke, rehospitalisation for cardiac reasons, kidney failure and major bleeding at 30 days.

Summary: FAST-TAVI registry 2019: prespecified discharge criteria validated in 502 patients — 30-day mortality 1.1%, composite complications 12.9%

Result: The primary composite was reached in 12.9% of patients at 30 days. Thirty-day mortality was 1.1%; stroke/TIA 1.7%; pacemaker implantation 7.3%; major vascular complications 1.9%; major or life-threatening bleeding 2.4%; cardiac rehospitalisation 3.7%. Patients appropriately discharged early had a significantly lower risk of the primary endpoint than patients not discharged early (7.0% versus 26.4%; P < 0.001). The tested product pathway used the balloon-expandable SAPIEN 3 valve (Edwards Lifesciences) per the registry design.

Watch out: The early-versus-late discharge comparison is not randomised: the criteria deliberately send lower-risk patients home early, so their lower complication rate shows the criteria select well, not that early discharge itself prevents complications.

Source: Barbanti M, van Mourik MS, Spence MS et al.. EuroIntervention. 2019. PMID: 30777842. Registry ID: NCT02404467. MeSH: Aortic Valve · Aortic Valve Stenosis · Europe · Humans · Patient Discharge · Prospective Studies · Registries · Risk Factors · Transcatheter Aortic Valve Replacement · Treatment Outcome

Card 2 — FAST-TAVI II 2024: a quality-measures programme raised discharge within 3 days from 42.3% to 58.1% and cut median stay from 4 to 3 days

Study: Cluster-randomised controlled trial (1,829 patients enrolled)

Population: Prospective multicentre cluster-randomised controlled trial in severe symptomatic aortic stenosis undergoing transfemoral TAVI: centres randomised to a dedicated training programme implementing 10 quality-of-care measures (969 patients) or control care (860 patients), with an 8-week implementation phase. Mean age 81.9 years; mean EuroSCORE II 4.4%. The primary endpoint was discharge early, within 3 days.

Summary: FAST-TAVI II 2024: a quality-measures programme raised discharge within 3 days from 42.3% to 58.1% and cut median stay from 4 to 3 days

Result: Early discharge was achieved in 58.1% of the intervention group versus 42.3% of controls (P < 0.0001), and median length of stay was 3 days versus 4 days (P < 0.0001). Thirty-day mortality was low and similar (0.5% versus 0.9%; P = 0.30), as were 30-day readmissions (4.6% versus 2.8%; P = 0.28).

Watch out: Cluster randomisation by centre, an unblinded care-pathway intervention, and a readmission rate that was numerically higher in the intervention group (4.6% versus 2.8%, not significant) — the trial shows the programme is implementable and shortens stay; it is not powered to exclude a small readmission cost.

Source: Durand E, Beziau-Gasnier D, Michel M et al.. Eur Heart J. 2024. PMID: 38437633. Registry ID: NCT04503655. MeSH: Humans · Aged · Aged, 80 and over · Transcatheter Aortic Valve Replacement · Aortic Valve Stenosis / surgery · Length of Stay · Prospective Studies · Patient Discharge · Treatment Outcome · Aortic Valve / surgery · Risk Factors

Card 3 — Synthesis: criteria-based early discharge after transfemoral TAVI is feasible and shortens stay by about a day, with no detected 30-day safety penalty in 2,331 patients

Study: Synthesis

Population: The carded record: the FAST-TAVI registry (502 patients) and the FAST-TAVI II cluster-randomised trial (1,829 patients). Total documented N = 2,331; independent cohorts, additive.

Summary: Synthesis: criteria-based early discharge after transfemoral TAVI is feasible and shortens stay by about a day, with no detected 30-day safety penalty in 2,331 patients

Result: One randomised trial (at cluster level) plus one prospective validation registry, concordant: the pathway works as a pathway. The stamp is POSSIBLE and Tier C because the randomised unit is the centre, the intervention is a bundle of 10 measures whose active ingredients cannot be separated, and safety endpoints are low-event and imprecise.

Watch out: Non-transfemoral access, patients needing pacemaker implantation or with major periprocedural complications, and health systems without next-day review capacity are outside what these cohorts tested.

Source: Synthesis of the carded records above (PMIDs 30777842, 38437633). Registry IDs: NCT02404467, NCT04503655.