SourceMed · Shelf #12023 in the ask interface

Single-use versus reusable flexible ureteroscopes: two meta-analyses (12 and 11 studies) found no difference in stone-free rate (odds ratio 1.31 and 1.36 relative), operating time or complications — neither abstract states a patient total (no documented N)

Shelf #12023 · Urology & men’s health

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2022–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In retrograde intrarenal surgery for urinary stones, do single-use (disposable) flexible ureteroscopes give stone-free rates, operating time and complications equivalent to reusable flexible ureteroscopes?

Balance of the evidence

POSSIBLE (the treatment made no difference) — Composition: two overlapping systematic reviews and meta-analyses (12 and 11 comparative studies); neither abstract states a combined patient total, so this pack has no documented total N — that is stated here and on the cards, no number is imported, and the pack is flagged on that basis rather than held as an under-30 pile pack (the pile rule applies to a stated total under 30). Stone-free rates, operating time, hospital stay, fever, urinary infection and overall complications did not differ between single-use and reusable scopes in either analysis; both sets of authors conclude the choice rests on availability, cost analysis and surgeon preference. The stamp is POSSIBLE and Tier C: the evidence is two overlapping syntheses without a carded patient total. Adjacent technique shelves are separate questions: thulium fibre laser #10163, suction access sheaths #10809, ureteroscopy versus shock-wave lithotripsy #6234 and #11401, dusting versus basket extraction #11727. Neither record states a registry ID for the review itself (the Jun review states its PROSPERO registration, CRD42022331291, in its abstract).

MeSH: Equipment Design · Equipment Reuse* · Humans · Kidney Calculi / surgery* · Treatment Outcome · Ureteroscopes · Ureteroscopes* · Ureteroscopy · Urinary Calculi* · Urolithiasis*

Cards (3)

Card 1 — Belkovsky 2024: across 12 comparative studies, single-use and reusable ureteroscopes did not differ — stone-free odds ratio 1.31 relative (95% CI 0.88–1.97), operating-time mean difference 0.12 minutes

Study: Systematic review and meta-analysis (12 studies; patient total not stated in the record)

Population: Systematic review and meta-analysis (search October 2022; 10,039 articles retrieved, 12 selected) comparing single-use with reusable flexible ureteroscopes in retrograde intrarenal surgery for urinary stones. The abstract states the number of studies, not a combined patient total — no patient total is stated in the record.

Summary: Belkovsky 2024: across 12 comparative studies, single-use and reusable ureteroscopes did not differ — stone-free odds ratio 1.31 relative (95% CI 0.88–1.97), operating-time mean difference 0.12 minutes

Result: No differences were found in stone-free rate (odds ratio 1.31 relative, 95% CI 0.88 to 1.97), operative time (mean difference 0.12, 95% CI −5.52 to 5.76), postoperative fever (odds ratio 0.64 relative, 95% CI 0.22 to 1.89) or postoperative urinary tract infection (odds ratio 0.63 relative, 95% CI 0.30 to 1.32). The authors conclude the device choice should rely on availability, cost analysis and surgeon preference.

Watch out: Equivalence is asserted from non-significant differences, not from a powered equivalence margin; the confidence interval for stone-free rate (0.88–1.97) is wide enough to hide a clinically meaningful difference either way.

Source: Belkovsky M, Passerotti CC, Maia RS et al.. Comparing outcomes of single-use vs reusable ureteroscopes: a systematic review and meta analysis. Urolithiasis. 2024. PMID: 38413490. Registry ID: none stated in the record. MeSH: Humans · Equipment Design · Ureteroscopes* · Ureteroscopy · Urinary Calculi* · Urolithiasis* · Equipment Reuse*

Card 2 — Jun 2022: 11 comparative studies — no difference in stone-free rate (odds ratio 1.36 relative, 95% CI 0.9–2.04), operation time, hospital stay or complications

Study: Systematic review and meta-analysis (11 studies; patient total not stated in the record)

Population: Systematic review and meta-analysis under PRISMA, registered with PROSPERO (CRD42022331291), of clinical trials comparing disposable with reusable flexible ureteroscopic stone surgery for upper urinary tract stones, searched to March 2022; 11 studies met eligibility. The abstract states study counts at each screening stage, not a combined patient total — no patient total is stated in the record.

Summary: Jun 2022: 11 comparative studies — no difference in stone-free rate (odds ratio 1.36 relative, 95% CI 0.9–2.04), operation time, hospital stay or complications

Result: Stone-free rate did not differ (P = 0.14; odds ratio 1.36 relative, 95% CI 0.9 to 2.04), nor did operation time (mean difference −5.31, 95% CI −12.08 to 1.46), hospital stay (mean difference −0.03, 95% CI −0.17 to 0.10) or complication rate (odds ratio 0.95 relative, 95% CI 0.56 to 1.61). The authors conclude disposable scopes are a comparable alternative.

Watch out: The two carded syntheses overlap heavily in their included studies, so they are one body of evidence read twice, not two independent confirmations.

Source: Jun DY, Cho KS, Jeong JY et al.. Comparison of Surgical Outcomes between Single-Use and Reusable Flexible Ureteroscopes for Renal Stone Management: A Systematic Review and Meta-Analysis. Medicina (Kaunas). 2022. PMID: 36295549. Registry ID: PROSPERO CRD42022331291 (the review's registration, stated in the record); no trial registry ID is stated. MeSH: Humans · Ureteroscopes · Equipment Design · Kidney Calculi / surgery* · Ureteroscopy · Urinary Calculi* · Treatment Outcome

Card 3 — Synthesis: on the carded outcomes the two scope types perform the same — the decision is cost, sterility logistics and repair burden, which the clinical syntheses do not price

Study: Synthesis

Population: The carded record: Belkovsky 2024 (12 studies) and Jun 2022 (11 studies), overlapping syntheses; neither states a patient total, so the pack has no documented total N and is flagged on that basis, not pile-held.

Summary: Synthesis: on the carded outcomes the two scope types perform the same — the decision is cost, sterility logistics and repair burden, which the clinical syntheses do not price

Result: Stone-free rates, operating time, stay and complications are statistically indistinguishable in both analyses, earning POSSIBLE (the treatment made no difference). Cost per case, scope longevity and infection-from-reprocessing outcomes are the real-world axes of this choice and are not quantified in either abstract.

Watch out: Newer single-use models and centre-specific reprocessing quality move faster than these 2022–2024 syntheses; a centre with frequent reusable-scope repairs is outside the pooled average.

Source: Synthesis of the carded records above (PMIDs 38413490, 36295549). Registry ID: PROSPERO CRD42022331291 (Jun review) as stated in its record.