SourceMed · Shelf #12076 in the ask interface

Air versus SF6 gas tamponade for macular holes up to 400 micrometres: the randomised noninferiority trial found air inferior (closure 90% versus 100% per protocol), while a 211-eye retrospective series found no difference (95% versus 97.5% closure) — SPLIT (documented N = 361)

Shelf #12076 · Eyes, skin, nose & allergy

SPLIT

Stamped: 2026-11-28.

Evidence published: 2020–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients having vitrectomy with internal limiting membrane peeling for a small or medium-sized full-thickness macular hole, does air tamponade close the hole as reliably as sulfur hexafluoride (SF6) gas tamponade?

Balance of the evidence

SPLIT — The two carded designs disagree. The randomised noninferiority trial (150 patients, holes up to 400 micrometres, nonsupine positioning for 3 days) found air inferior: primary closure was 65 of 75 (86.7%) on air versus 75 of 75 (100%) on SF6 in the intention-to-treat analysis, and 90% versus 100% per protocol, with the confidence interval for the difference crossing the 10-percentage-point noninferiority margin in both analyses; in the small-hole subgroup (up to 250 micrometres) every hole closed in both groups. The 211-eye retrospective series, where the surgeon chose the agent, found the opposite pattern: failure to close in 1 of 40 air eyes (2.5%) versus 9 of 171 gas eyes (5.3%), no significant difference (P = 0.45). SPLIT, because the higher-grade evidence says SF6 closes more medium-sized holes while routine-practice data say the choice rarely matters. Boundaries: tamponade choice for detachment with proliferative vitreoretinopathy is shelf #10130, face-down posturing after macular hole surgery is shelf #6621, and the inverted flap technique for large holes is shelf #6784 — all different questions.

MeSH: Endotamponade / methods · Humans · Prone Position · Prospective Studies · Retinal Perforations* / diagnosis / surgery · Sulfur Hexafluoride · Visual Acuity

Cards (3)

Card 1 — Randomised noninferiority trial 2022: 150 patients — air inferior to SF6 (per-protocol closure 90% versus 100%); all small holes closed in both groups

Study: Randomised controlled trial, noninferiority (150 patients randomised)

Population: Multicentre randomised controlled noninferiority trial: patients aged 18 or over having vitrectomy with internal limiting membrane peeling for primary macular holes of 400 micrometres diameter or less, randomised at the end of surgery to air (75 patients) or SF6 gas (75 patients) tamponade, stratified by hole size, with a nonsupine positioning regimen for 3 days. The primary endpoint was closure after a single surgery, confirmed by optical coherence tomography at 2–8 weeks; the noninferiority margin was 10 percentage points.

Summary: Randomised noninferiority trial 2022: 150 patients — air inferior to SF6 (per-protocol closure 90% versus 100%); all small holes closed in both groups

Result: In the intention-to-treat analysis, 65 of 75 air patients achieved primary closure versus 75 of 75 on SF6. Per protocol (6 patients excluded), closure was 63 of 70 (90%; 95% CI 79.9%–95.5%) on air versus 74 of 74 (100%; 95% CI 93.9%–100%) on SF6, and the lower bound of the confidence interval for the difference exceeded the 10-point noninferiority margin in both analyses — air was inferior. In the small-hole subgroup (250 micrometres or less), all 20 air and all 28 SF6 patients achieved primary closure.

Watch out: Holes over 400 micrometres were excluded, and the result is tied to the trial's 3-day nonsupine regimen: it does not answer air versus gas for large holes or under strict face-down posturing.

Source: Lindtjørn B, Krohn J, Haugstad M, Stene-Johansen I, Austeng D, Basit S. Air versus Sulfur Hexafluoride Gas Tamponade for Small and Medium-Sized Macular Holes: A Randomized Noninferiority Trial. Ophthalmol Retina. 2022. PMID: 35398546. Registry ID: NCT03572725. MeSH: Endotamponade / methods · Humans · Prone Position · Prospective Studies · Retinal Perforations* / diagnosis / surgery · Sulfur Hexafluoride · Visual Acuity

Card 2 — Retrospective series 2020: 211 eyes — closure 97.5% with air versus 94.7% with gas, no significant difference (P = 0.45)

Study: Retrospective comparative series (211 eyes)

Population: Retrospective consecutive review at an academic practice, 2010–2017: 211 eyes having vitrectomy for idiopathic full-thickness macular hole; gas tamponade in 171 eyes (144 sulfur hexafluoride, the remainder perfluoropropane) and fluid–air exchange only in 40 eyes, at surgeon discretion (not randomised). Preoperative hole size did not differ significantly between groups (P = 0.43).

Summary: Retrospective series 2020: 211 eyes — closure 97.5% with air versus 94.7% with gas, no significant difference (P = 0.45)

Result: Nine of 171 gas eyes (5.3%) and 1 of 40 air eyes (2.5%) failed to close — closure 94.7% versus 97.5%, no statistically significant difference (P = 0.45). The authors concluded air served as an equally efficacious tamponade in their practice.

Watch out: Surgeon choice of agent invites confounding by hole size and surgeon preference, and the gas group mixes two gases; this design cannot overturn the randomised result — it is carded because it is the discordant half of a genuinely split record.

Source: Patel SN, Law J, Cherney E, Recchia F, Kim SJ. Air vs Gas Tamponade During Macular Hole Repair Surgery. J Vitreoretin Dis. 2020. PMID: 37008289. Registry ID: none stated in the record. MeSH: The record assigns no MeSH terms.

Card 3 — Synthesis: randomised evidence favours SF6 for medium-sized holes; practice data find no difference — the honest stamp is SPLIT

Study: Synthesis

Population: The carded record: the randomised noninferiority trial (150 patients) and the retrospective series (211 eyes), separate designs and populations, additive. Total documented N = 361.

Summary: Synthesis: randomised evidence favours SF6 for medium-sized holes; practice data find no difference — the honest stamp is SPLIT

Result: For small holes both agents closed everything in the trial. For holes approaching 400 micrometres, the randomised data say air costs closures; the retrospective data say it does not. SPLIT.

Watch out: Positioning after surgery (#6621) and flap technique for large holes (#6784) interact with tamponade choice but are separate shelves.

Source: Synthesis of the carded records above (PMIDs 35398546, 37008289). Registry IDs: NCT03572725 (trial); none stated in the series record.