Closed-loop IntelliVent-ASV versus conventional ventilation: similar safety, more time in optimal tidal-volume and saturation ranges, fewer manual adjustments over 48 hours — process outcomes only in two small trials (documented N = 130)
Shelf #12092 · Critical care & sepsis
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2012–2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In critically ill adults receiving invasive mechanical ventilation, does fully closed-loop ventilation (INTELLiVENT-ASV / IntelliVent-ASV) deliver ventilation as safely and effectively as conventional modes, with less clinician workload?
Balance of the evidence
POSSIBLE (benefit) — benefit confined to ventilation-process outcomes, stated here because the stamp alone would overclaim. Composition: two small randomised studies, total documented N = 130 (a 50-patient 2-hour crossover against plain ASV and an 80-patient 48-hour trial against conventional modes). The closed-loop mode delivered lower plateau pressures and FiO2 in the crossover (20 versus 24 cm H2O; 30% versus 40%), spent more time in the optimal tidal-volume and saturation ranges over 48 hours, and needed significantly fewer manual adjustments — while maximum pressure was more often outside the optimal range, a safety caveat printed on the card. No carded trial reports duration of ventilation, liberation, length of stay or mortality; the adequately powered ACTiVE trial exists in the record only as a protocol (PMID 35461264) and is not evidence. The mode is named exactly as the publications name it (IntelliVent-ASV / INTELLiVENT-ASV); proportional assist ventilation is a different automation question and is shelved separately at #12091.
MeSH: Aged · Aged, 80 and over · Brain Injuries / therapy · Cross-Over Studies · Deep Sedation* · Female · France · Humans · Hypercapnia / therapy · Intensive Care Units · Intensive Care Units* · Male · Middle Aged · Monitoring, Physiologic · Outcome Assessment, Health Care / methods* · Prospective Studies · Respiration, Artificial / adverse effects · Respiration, Artificial / methods* · Respiratory Distress Syndrome / therapy* · Respiratory Physiological Phenomena · Safety Management* · Time Factors
Cards (3)
Card 1 — Arnal 2012 crossover: IntelliVent-ASV ventilated passive ICU patients with less pressure, volume and oxygen than plain ASV — plateau pressure 20 versus 24 cm H2O, FiO2 30% versus 40%
Study: Randomised crossover study (50 patients)
Population: Prospective randomised crossover study in a 12-bed general-hospital intensive care unit: 50 sedated, passively ventilated patients with acute respiratory failure each received 2 hours of adaptive support ventilation (ASV) and 2 hours of IntelliVent-ASV in randomly assigned order, with breath-by-breath monitoring and respiratory mechanics and blood gases measured at the end of each period.
Summary: Arnal 2012 crossover: IntelliVent-ASV ventilated passive ICU patients with less pressure, volume and oxygen than plain ASV — plateau pressure 20 versus 24 cm H2O, FiO2 30% versus 40%
Result: During IntelliVent-ASV, minute ventilation fell from 7.6 to 6.8 L/min (P < 0.001) and tidal volume from 8.3 to 8.1 mL/kg predicted body weight (P = 0.003); plateau pressure fell from 24 to 20 cm H2O (P = 0.005) and FiO2 from 40% to 30% (P < 0.001), with respiratory rate, inspiratory pressure and PEEP also lower. pH, PaO2 and the PaO2/FiO2 ratio did not differ; PaCO2 was slightly higher on IntelliVent-ASV. No safety issue required premature interruption of the closed-loop mode.
Watch out: Two-hour periods in passive, deeply sedated patients: the study shows the controller can run safely and gently for 2 hours, nothing about days of ventilation, weaning or outcomes. The comparator is plain ASV — itself an automated mode — not clinician-set conventional ventilation.
Source: Arnal JM, Wysocki M, Novotni D et al. Safety and efficacy of a fully closed-loop control ventilation (IntelliVent-ASV®) in sedated ICU patients with acute respiratory failure: a prospective randomized crossover study. Intensive Care Med. 2012. PMID: 22460854. Registry ID: none stated in the record. MeSH: Aged · Aged, 80 and over · Cross-Over Studies · Deep Sedation* · Female · France · Humans · Intensive Care Units* · Male · Middle Aged · Monitoring, Physiologic · Outcome Assessment, Health Care / methods* · Prospective Studies · Respiration, Artificial / methods* · Respiratory Distress Syndrome / therapy* · Safety Management*
Card 2 — Bialais 2016: over 48 hours IntelliVent-ASV needed fewer manual adjustments than conventional modes and kept tidal volume and oxygen saturation in the optimal range more often, with similar safety
Study: Randomised controlled trial (80 patients analysed)
Population: Randomised controlled trial: 80 intensive care patients expected to need mechanical ventilation for more than 48 hours were randomised to IntelliVent-ASV or conventional ventilation modes and followed for 48 hours with breath-by-breath recording of all ventilation parameters; workload was assessed by the number of manual adjustments, and safety and efficacy by time spent within predefined non-optimal and optimal ranges.
Summary: Bialais 2016: over 48 hours IntelliVent-ASV needed fewer manual adjustments than conventional modes and kept tidal volume and oxygen saturation in the optimal range more often, with similar safety
Result: Median ventilation parameters over 48 hours were similar between groups except PEEP (7 versus 6 cm H2O; P = 0.028) and end-tidal CO2 (36 versus 40 mmHg; P = 0.041), both lower or higher as printed for IntelliVent-ASV versus conventional. Safety was similar for all parameters except maximum pressure, which was more often non-optimal with IntelliVent-ASV (P = 0.001). Tidal volume and oxygen saturation were more often in the optimal range with IntelliVent-ASV (P = 0.016 and P = 0.005). IntelliVent-ASV required fewer manual adjustments (P < 0.001) while making more adjustments in total — the automation doing the adjusting.
Watch out: Every endpoint is a ventilation-quality or workload measure over 48 hours; no duration-of-ventilation, liberation or survival outcome is reported. The large ACTiVE trial designed to test ventilator-free days (protocol, PMID 35461264) was still a protocol in the record set checked for this shelf and is not carded as evidence.
Source: Bialais E, Wittebole X, Vignaux L et al. Closed-loop ventilation mode (IntelliVent®-ASV) in intensive care unit: a randomized trial. Minerva Anestesiol. 2016. PMID: 26957117. Registry ID: none stated in the record. MeSH: Aged · Brain Injuries / therapy · Female · Humans · Hypercapnia / therapy · Intensive Care Units · Male · Middle Aged · Prospective Studies · Respiration, Artificial / adverse effects · Respiration, Artificial / methods* · Respiratory Distress Syndrome / therapy* · Respiratory Physiological Phenomena · Time Factors
Card 3 — Synthesis: two small short-horizon trials — closed-loop IntelliVent-ASV runs ventilation at least as safely as conventional care with fewer manual adjustments, and no carded trial shows it shortening ventilation or saving lives
Study: Synthesis
Population: The carded record: Arnal 2012 (50 patients, crossover) and Bialais 2016 (80 patients); total documented N = 130, independent studies, additive.
Summary: Synthesis: two small short-horizon trials — closed-loop IntelliVent-ASV runs ventilation at least as safely as conventional care with fewer manual adjustments, and no carded trial shows it shortening ventilation or saving lives
Result: Both trials are about how ventilation is delivered, not what it achieves for the patient: gentler settings, more time in target ranges, less clinician workload. That supports POSSIBLE (benefit) confined to those process outcomes, Tier C, and the face states the limit plainly: no carded randomised evidence yet links the mode to faster liberation or lower mortality.
Watch out: The tested product is named as the publications name it — IntelliVent-ASV, a closed-loop mode of a specific ventilator platform; the records do not test closed-loop control in the abstract, and other automated modes are other questions.
Source: Synthesis of the carded records above (PMIDs 22460854, 26957117). Registry IDs: none stated in either record.