SourceMed · Shelf #12119 in the ask interface

Cuffed versus uncuffed endotracheal tubes in children aged 8 years and under: postextubation stridor did not differ (risk ratio 0.93 relative), but tube exchanges were far fewer with cuffed tubes (risk ratio 0.07 relative) in a 3-trial Cochrane review (documented N = 2,804 children)

Shelf #12119 · Critical care & sepsis

SPLIT

Stamped: 2026-11-28.

Evidence published: 2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children aged eight years and under having general anaesthesia, does a cuffed endotracheal tube, compared with an uncuffed tube, change postextubation stridor and other airway outcomes?

Balance of the evidence

SPLIT — On the harm outcome that drove the historical preference for uncuffed tubes, the record is null: postextubation stridor did not differ between cuffed and uncuffed tubes (risk ratio 0.93 relative, 95% CI 0.65 to 1.33; 2,734 children). On the practical outcome, cuffed tubes were exchanged far less often (risk ratio 0.07 relative, 95% CI 0.05 to 0.10). Every estimate in this single Cochrane synthesis is low- or very-low-quality evidence, all three trials were rated high risk of bias, and the largest trial was supported by Microcuff GmbH, which provided the cuffed tubes — those limits are why the stamp is SPLIT at Tier C rather than a firmer verdict in either direction. No carded trial measured whether appropriate tidal volumes were delivered. This shelf was flagged as a reserve in wave 17 Block A and is built now because the Cochrane record resolves cleanly and gates clean in all three sources.

MeSH: Adrenal Cortex Hormones / therapeutic use · Anesthesia, General / instrumentation* · Bronchodilator Agents / therapeutic use · Child · Child, Preschool · Epinephrine / therapeutic use · Equipment Design* · Humans · Infant · Intensive Care Units, Neonatal / statistics & numerical data · Intubation, Intratracheal / adverse effects / economics / instrumentation* · Randomized Controlled Trials as Topic · Respiratory Sounds / etiology

Cards (2)

Card 1 — Cochrane 2017: stridor did not differ between cuffed and uncuffed tubes (risk ratio 0.93 relative), but cuffed tubes needed exchange far less often (risk ratio 0.07 relative)

Study: Systematic review (Cochrane) of randomised trials (3 trials, 2,804 children)

Population: Cochrane systematic review of randomised and quasi-randomised trials in children up to eight years old undergoing general anaesthesia (studies conducted solely in newborn babies excluded): 3 trials, 2,804 children, comparing cuffed with uncuffed endotracheal tubes. All three trials were rated high risk of bias; the largest was supported by Microcuff GmbH, which provided the cuffed tubes used.

Summary: Cochrane 2017: stridor did not differ between cuffed and uncuffed tubes (risk ratio 0.93 relative), but cuffed tubes needed exchange far less often (risk ratio 0.07 relative)

Result: Two trials (2,734 children) found no difference in postextubation stridor (risk ratio 0.93 relative, 95% CI 0.65 to 1.33; very low-quality evidence) but a statistically significantly lower rate of tube exchange with cuffed tubes (risk ratio 0.07 relative, 95% CI 0.05 to 0.10; very low-quality evidence). One trial with 70 participants found costs per case lower with cuffed tubes (mean difference EUR 19.0 lower, 95% CI 24.23 to 13.77 lower; low-quality evidence). No clear difference emerged for re-intubation to treat stridor (risk ratio 1.85 relative, 95% CI 0.17 to 19.76), epinephrine treatment (risk ratio 0.70 relative, 95% CI 0.38 to 1.28), corticosteroid treatment (risk ratio 0.87 relative, 95% CI 0.51 to 1.49) or intensive care admission for stridor (risk ratio 2.77 relative, 95% CI 0.30 to 25.78) — all very imprecise. No trial evaluated delivery of appropriate tidal volume.

Watch out: High risk of bias in every trial, very low-quality evidence for the headline outcomes, and industry support (tubes provided by Microcuff GmbH) in the largest trial; the exchange advantage is a process outcome, not proof of better ventilation — tidal-volume delivery was never measured.

Source: De Orange FA, Andrade RG, Lemos A, Borges PS, Figueiroa JN, Kovatsis PG. Cuffed versus uncuffed endotracheal tubes for general anaesthesia in children aged eight years and under. Cochrane Database Syst Rev. 2017. PMID: 29149469. Registry ID: none stated in the record. MeSH: Adrenal Cortex Hormones / therapeutic use · Anesthesia, General / instrumentation* · Bronchodilator Agents / therapeutic use · Child · Child, Preschool · Epinephrine / therapeutic use · Equipment Design* · Humans · Infant · Intensive Care Units, Neonatal / statistics & numerical data · Intubation, Intratracheal / adverse effects / economics / instrumentation* · Randomized Controlled Trials as Topic · Respiratory Sounds / etiology

Card 2 — Synthesis: cuffed tubes did not raise stridor and were exchanged far less often — a split record resting on very low-quality evidence

Study: Synthesis

Population: The carded record: the 2017 Cochrane review (3 trials); total documented N = 2,804 children, counted once from the review.

Summary: Synthesis: cuffed tubes did not raise stridor and were exchanged far less often — a split record resting on very low-quality evidence

Result: The feared harm (stridor) did not materialise and the practical benefit (fewer exchanges, lower cost per case in one small trial) favoured cuffed tubes, but the evidence quality is too weak for a firmer stamp. SPLIT at Tier C states exactly that.

Watch out: Newborn babies were excluded from the review's trials; nothing here answers the question in neonates or in prolonged intensive-care intubation.

Source: Synthesis of the carded record above (PMID 29149469).