SourceMed · Shelf #12124 in the ask interface
Digital versus analogue chest drainage after pulmonary resection: chest-tube duration and hospital stay were shorter with digital systems across 12 randomised trials (documented N = 2,000 patients), with no difference in prolonged air leak or cardiopulmonary complications in the pooled record
Shelf #12124 · Lungs, breathing & sleep
POSSIBLE (benefit)
Stamped: 2026-11-28.
Evidence published: 2017–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
After pulmonary resection, does a digital chest drainage system, compared with a conventional analogue system, shorten chest-tube duration and hospital stay?
Balance of the evidence
POSSIBLE (benefit) — A meta-analysis of 12 randomised trials (2,000 patients) found digital drainage shortened chest-tube placement (standardised mean difference -0.49, 95% CI -0.78 to -0.20) and hospital stay (mean difference -0.79 days, 95% CI -1.24 to -0.34), with no significant difference in prolonged air leak or cardiopulmonary complications. One carded primary trial (103 patients) points the same way on prolonged air leak (9 patients on analogue versus 2 on digital, P = 0.025) but found no difference in total fluid drained or stay — the pooled benefit is a process benefit (tubes out sooner, home sooner), not a demonstrated reduction in complications, and the stamp says POSSIBLE at Tier C for a single synthesis. Total documented N = 2,000, counted once from the synthesis; the carded primary trial sits inside the randomised-trial era the synthesis covers and is not added. Wave 17 Block A flagged digital chest drainage as an unverified reserve; it is built now on this record.
MeSH: Humans · Pneumonectomy* · Randomized Controlled Trials as Topic · Drainage* / adverse effects · Chest Tubes · Length of Stay · Postoperative Complications / therapy
Cards (3)
Card 1 — Meta-analysis 2023: digital drainage shortened chest-tube time and stay (mean difference -0.79 days) across 12 randomised trials; prolonged air leak and complications did not differ
Study: Systematic review and meta-analysis of randomised trials (12 trials, 2,000 patients)
Population: Systematic review and meta-analysis of randomised trials of digital versus analogue chest drainage after pulmonary resection: 12 trials, 2,000 patients.
Summary: Meta-analysis 2023: digital drainage shortened chest-tube time and stay (mean difference -0.79 days) across 12 randomised trials; prolonged air leak and complications did not differ
Result: Duration of chest-tube placement was shorter with digital drainage (standardised mean difference -0.49, 95% CI -0.78 to -0.20) and length of hospital stay was shorter (mean difference -0.79 days, 95% CI -1.24 to -0.34). The number of chest-tube clamping tests did not differ significantly (risk ratio 0.74 relative, 95% CI 0.36 to 1.49), and the groups did not differ significantly in prolonged air leak or cardiopulmonary complication rate.
Watch out: Tube-removal decisions in the underlying trials were made by teams who could see which system was in use, so shorter tube time may partly reflect confidence in the digital readout rather than faster healing; costs were not settled by this record.
Source: Zhou L, Guo K, Shang X, E F, Xu M, Wu Y. Advantages of applying digital chest drainage system for postoperative management of patients following pulmonary resection: a systematic review and meta-analysis of 12 randomized controlled trials. Gen Thorac Cardiovasc Surg. 2023. PMID: 36175611. Registry ID: none stated in the record. MeSH: Humans · Pneumonectomy* · Randomized Controlled Trials as Topic · Drainage* / adverse effects · Chest Tubes · Length of Stay · Postoperative Complications / therapy
Card 2 — Randomised trial 2017: digital drainage did not reduce pleural fluid volume or stay, but prolonged air leak was commoner on analogue drainage (9 versus 2 patients)
Study: Randomised controlled trial (103 patients)
Population: Prospective randomised trial in oncologic pulmonary resection: 103 patients randomised to analogue (50) or digital (53) drainage, with chest tubes removed by a standardised pre-defined protocol; pleural and serum inflammatory mediators were also measured.
Summary: Randomised trial 2017: digital drainage did not reduce pleural fluid volume or stay, but prolonged air leak was commoner on analogue drainage (9 versus 2 patients)
Result: There was no significant difference in total fluid drained or length of hospital stay. A trend to shorter chest-tube duration with the digital system was found (P = 0.055). Prolonged postoperative air leak was significantly commoner with the analogue system (9 versus 2 patients, P = 0.025). Inflammatory mediator levels did not differ between systems. Lobectomy, versus sub-lobar resection, meant longer tube duration and more fluid drainage regardless of system.
Watch out: A single-centre trial of 103 patients: its stay result is null where the pooled result is positive, and its air-leak counts are small (9 versus 2) — it supports, but cannot carry, the pooled conclusion.
Source: De Waele M, Agzarian J, Hanna WC, Schieman C, Finley CJ, Macri J. Does the usage of digital chest drainage systems reduce pleural inflammation and volume of pleural effusion following oncologic pulmonary resection? — A prospective randomized trial. J Thorac Dis. 2017. PMID: 28740674. Registry ID: none stated in the record. MeSH: The record assigns no MeSH terms.
Card 3 — Synthesis: digital drainage gets tubes out and patients home sooner on the pooled record, without a shown fall in complications
Study: Synthesis
Population: The carded record: the 2023 meta-analysis (12 randomised trials) and the 2017 randomised trial; total documented N = 2,000, counted once from the synthesis (the trial is not added).
Summary: Synthesis: digital drainage gets tubes out and patients home sooner on the pooled record, without a shown fall in complications
Result: Process outcomes favour digital systems in the pooling; the one carded primary trial is more equivocal. POSSIBLE (benefit).
Watch out: Drainage for empyema, pneumothorax without resection, and paediatric chest drainage are different questions and are outside this shelf.