SourceMed · Shelf #12193 in the ask interface

aMAZE 2024: appendage ligation plus vein isolation did not meet its superiority criterion — freedom from atrial arrhythmias at 12 months 64.3% versus 59.9% (posterior superiority probability 0.835 against a 0.977 threshold), with the 30-day safety criterion met (documented N = 610 randomised)

Shelf #12193 · Heart, vessels, blood pressure & clotting

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with nonparoxysmal atrial fibrillation, does adding percutaneous left atrial appendage ligation with the LARIAT system to catheter pulmonary vein isolation improve freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone?

Balance of the evidence

POSSIBLE (the treatment made no difference) — Composition: one multicentre open-label randomised trial (aMAZE, 610 patients, 53 US sites) with a Bayesian adaptive design. Freedom from documented atrial arrhythmias over 30 seconds at 12 months was 64.3% with appendage ligation plus pulmonary vein isolation versus 59.9% with isolation alone — a difference of 4.3% (Bayesian 95% credible interval, -4.2% to 13.2%) with a posterior superiority probability of 0.835, short of the prespecified 0.977 criterion, so superiority was not established; the stamp records that the treatment made no proven difference, not that a small benefit is excluded. The safety criterion was met: 30-day serious adverse events 3.4% against a 10% performance goal, and complete appendage closure at 12 months was seen in 84% (99% at 5 mm residual communication or less). The tested product is named as the record names it: the LARIAT system for percutaneous suture ligation of the appendage. Boundary: this is a rhythm-control adjunct question, not stroke prophylaxis — appendage occlusion devices for stroke are owned by #2249/#2258 and surgical appendage occlusion by ask #2273; hybrid surgical-catheter ablation is #3317.

MeSH: Humans · Atrial Appendage* / surgery · Atrial Fibrillation* / surgery · Bayes Theorem · Organothiophosphorus Compounds* · Prospective Studies · Pulmonary Veins* / surgery · Catheter Ablation · Catheterization

Cards (2)

Card 1 — aMAZE 2024: ligation plus isolation gave 64.3% freedom from atrial arrhythmias at 12 months versus 59.9% for isolation alone — posterior superiority probability 0.835, below the 0.977 criterion, so superiority was not established

Study: Randomised controlled trial, open-label, Bayesian adaptive (610 patients randomised)

Population: Multicentre, prospective, open-label randomised trial at 53 US sites: 610 patients with nonparoxysmal atrial fibrillation present for less than 3 years, randomised 2:1 to percutaneous left atrial appendage ligation (LARIAT system) plus pulmonary vein isolation (404 patients) or pulmonary vein isolation alone (206). Enrolment ran from October 2015 to December 2019, with final follow-up in April 2021. The primary effectiveness endpoint was freedom from documented atrial arrhythmias longer than 30 seconds at 12 months, assessed by Holter monitoring at 6 and 12 months, symptomatic event monitoring and any electrocardiographic tracing; the primary safety endpoint was a composite of predefined serious adverse events at 30 days against a prespecified 10% performance goal.

Summary: aMAZE 2024: ligation plus isolation gave 64.3% freedom from atrial arrhythmias at 12 months versus 59.9% for isolation alone — posterior superiority probability 0.835, below the 0.977 criterion, so superiority was not established

Result: Primary effectiveness was 64.3% with ligation plus isolation and 59.9% with isolation alone (difference 4.3%; Bayesian 95% credible interval, -4.2% to 13.2%; posterior superiority probability 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (Bayesian 95% credible interval, 2.0% to 5.0%), below the 10% threshold. At 12 months, complete appendage closure (0 mm residual communication) was observed in 84% of patients and residual communication of 5 mm or less in 99%.

Watch out: The credible interval runs from -4.2% to +13.2%, so a worthwhile benefit is not excluded — the trial failed its own superiority bar, which is a statement about proof, not about the true effect being zero; the 2:1 randomisation was chosen to accumulate device experience, not statistical efficiency.

Source: Lakkireddy DR, Wilber DJ, Mittal S et al.. Pulmonary Vein Isolation With or Without Left Atrial Appendage Ligation in Atrial Fibrillation: The aMAZE Randomized Clinical Trial. JAMA. 2024. PMID: 38563835. Registry ID: NCT02513797. MeSH: Humans · Atrial Appendage* / surgery · Atrial Fibrillation* / surgery · Bayes Theorem · Organothiophosphorus Compounds* · Prospective Studies · Pulmonary Veins* / surgery · Catheter Ablation · Catheterization

Card 2 — Synthesis: one large randomised trial did not establish that adding LARIAT appendage ligation to vein isolation improves 12-month rhythm outcomes — safety and closure criteria were met

Study: Synthesis

Population: The carded record: the aMAZE trial alone; total documented N = 610 randomised.

Summary: Synthesis: one large randomised trial did not establish that adding LARIAT appendage ligation to vein isolation improves 12-month rhythm outcomes — safety and closure criteria were met

Result: The procedure did what it mechanically promises (84% complete closure at 12 months, 3.4% serious adverse events at 30 days) without a proven rhythm dividend at 12 months. Single trial, criterion not met: POSSIBLE (the treatment made no difference).

Watch out: Subgroup claims by atrial size or arrhythmia duration are not carded here and do not change the primary verdict; this shelf does not address appendage ligation or occlusion for stroke prophylaxis.

Source: Synthesis of the carded record above (PMID 38563835). Registry ID: NCT02513797.