SourceMed · Shelf #12198 in the ask interface

Transcatheter versus surgical closure of secundum atrial septal defect: closure success was equivalent (98.5% versus 100% primary efficacy in the 596-patient multicentre comparison), with fewer complications on the device route (7.2% versus 24.0%) and a shorter stay (1.0 versus 3.4 days) — nonrandomised, anatomy-selected (documented N = 718)

Shelf #12198 · Heart, vessels, blood pressure & clotting

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 1999–2002.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children and adults with a secundum atrial septal defect suitable for either approach, how does transcatheter closure with the Amplatzer septal occluder compare with surgical closure for closure success, complications and hospital stay?

Balance of the evidence

POSSIBLE (benefit) — Composition: two nonrandomised concurrent comparisons (718 patients in total), no randomised trial. In the 29-centre comparison (596 patients; device 442, surgery 154, allocated by patient option), attempt success was 95.7% for device and 100% for surgery, efficacy success rates did not differ significantly, complications were 7.2% versus 24.0% (P < 0.001) and mean stay was 1.0 versus 3.4 days (P < 0.001), with no mortality in either group. In the single-centre comparison (122 patients), closure rates were identical (98%) and stay was 3 versus 8 days (P < .001). The benefit in the stamp is a route benefit — equal closure with fewer complications and a shorter stay — not a claim that device closure closes defects surgery cannot. The stamp is POSSIBLE and Tier C because allocation was by anatomy and choice: defects unsuitable for a device went to surgery, device patients were older (median 9.8 versus 4.1 years in the multicentre study), and surgical defects were larger in the single-centre study, so the complication gap is inflated by selection to an unknown degree. The tested product is named as the records name it: the Amplatzer septal occluder (AGA Medical Corporation, in the 1999 record). Boundary: patent foramen ovale closure after cryptogenic stroke is a different question (#10149 and #11510); this shelf covers secundum atrial septal defect only.

MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cardiac Catheterization · Child · Child, Preschool · Female · Heart Septal Defects, Atrial / surgery*, therapy* · Humans · Infant · Length of Stay · Male · Middle Aged · Prostheses and Implants · Treatment Outcome · Age Factors · Blood Circulation / physiology · Duodenal Ulcer / complications · Echocardiography, Transesophageal · Femoral Artery · Follow-Up Studies · Foreign-Body Migration / etiology · Heart · Heart Septal Defects, Atrial / diagnostic imaging, surgery* · Peptic Ulcer Perforation / complications · Prostheses and Implants* / adverse effects · Prosthesis Implantation / adverse effects · Pulmonary Circulation / physiology · Surgical Wound Infection / etiology · Thoracotomy / adverse effects · Ultrasonography, Interventional

Cards (3)

Card 1 — Multicentre comparison 2002: device and surgical closure of secundum ASD had equivalent efficacy success, but complications were 7.2% versus 24.0% and stay 1.0 versus 3.4 days

Study: Multicentre nonrandomised comparison (596 patients; 442 device, 154 surgery)

Population: Multicentre nonrandomised concurrent study at 29 paediatric cardiology centres (March 1998 to March 2000): 442 patients underwent transcatheter closure with the Amplatzer septal occluder and 154 underwent surgical closure, assigned by patient option. Median age was 9.8 years (device) versus 4.1 years (surgery) (P < 0.001); a single defect was present in 89.4% versus 80.5%; mean primary defect size was 13.3 ± 5.4 mm versus 14.2 ± 6.3 mm. Follow-up was 6 and 12 months (device) and 12 months (surgery).

Summary: Multicentre comparison 2002: device and surgical closure of secundum ASD had equivalent efficacy success, but complications were 7.2% versus 24.0% and stay 1.0 versus 3.4 days

Result: Procedural attempt success was 95.7% for device and 100% for surgery (P = 0.006). Early, primary and secondary efficacy success rates were 94.8%, 98.5% and 91.6% for device versus 96.1%, 100% and 89.0% for surgery (all P > 0.05). The complication rate was 7.2% for device versus 24.0% for surgery (P < 0.001), and mean hospital stay was 1.0 ± 0.3 versus 3.4 ± 1.2 days (P < 0.001). Mortality was 0% in both groups.

Watch out: Patients chose their route and anatomy gated the choice — the surgical group was younger with more multiple defects; the comparison shows what each route achieved in the patients selected for it, not what randomisation would show.

Source: Du ZD, Hijazi ZM, Kleinman CS et al.. Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. J Am Coll Cardiol. 2002. PMID: 12039500. Registry ID: none stated in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cardiac Catheterization · Child · Child, Preschool · Female · Heart Septal Defects, Atrial / surgery*, therapy* · Humans · Infant · Length of Stay · Male · Middle Aged · Prostheses and Implants · Treatment Outcome

Card 2 — Single-centre comparison 1999: closure rates identical (98%) for Amplatzer device and surgery, with hospital stay 3 versus 8 days

Study: Single-centre nonrandomised comparison (122 patients; 61 device, 61 surgery)

Population: Single-centre consecutive comparison (May 1997 to June 1998): all patients with a secundum atrial septal defect and a pulmonary/systemic flow ratio of at least 1.5:1 were enrolled; 61 patients underwent surgical closure (median age 20 years) and 61 had the defect closed with an Amplatzer device (AGA Medical Corporation, Golden Valley, Minnesota) (median age 12 years), with defects not feasible for device closure going to surgery. Defect and shunt sizes were larger in the surgical group (P < .001).

Summary: Single-centre comparison 1999: closure rates identical (98%) for Amplatzer device and surgery, with hospital stay 3 versus 8 days

Result: Closure rates were identical in the two groups (98%). Hospital stay was 8 days (range 6-19) after surgery versus 3 days (3-14) after device closure (P < .001). Complications described were a perforated duodenal ulcer and an infected thoracotomy wound in the surgical group, and one device embolisation to the left ventricle — retrieved from the heart, with vascular surgery needed to extract it from the femoral artery — in the device group. The authors state they prefer device implantation wherever possible.

Watch out: The surgical group had larger defects and shunts by design (infeasible anatomy was routed to surgery), so equivalence of closure rates was achieved on easier device anatomy; device embolisation, though rare, is a device-specific harm with no surgical counterpart.

Source: Berger F, Vogel M, Alexi-Meskishvili V et al.. Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects. J Thorac Cardiovasc Surg. 1999. PMID: 10504632. Registry ID: none stated in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Blood Circulation / physiology · Cardiac Catheterization · Child · Child, Preschool · Duodenal Ulcer / complications · Echocardiography, Transesophageal · Femoral Artery · Follow-Up Studies · Foreign-Body Migration / etiology · Heart · Heart Septal Defects, Atrial / diagnostic imaging, surgery* · Humans · Infant · Length of Stay · Middle Aged · Peptic Ulcer Perforation / complications · Prostheses and Implants* / adverse effects · Prosthesis Implantation / adverse effects · Pulmonary Circulation / physiology · Surgical Wound Infection / etiology · Thoracotomy / adverse effects · Treatment Outcome · Ultrasonography, Interventional

Card 3 — Synthesis: in anatomy selected for either route, device closure matched surgical closure rates with fewer complications and days in hospital — a route benefit from nonrandomised comparisons

Study: Synthesis

Population: The carded record: the multicentre comparison (596 patients) and the single-centre comparison (122 patients); total documented N = 718, independent cohorts, additive.

Summary: Synthesis: in anatomy selected for either route, device closure matched surgical closure rates with fewer complications and days in hospital — a route benefit from nonrandomised comparisons

Result: Both comparisons agree: equivalent closure, fewer complications and a shorter stay on the device route, in patients whose anatomy allowed a device. POSSIBLE (benefit), Tier C — selection by anatomy runs through both studies and no randomised trial exists.

Watch out: Long-term device issues (erosion, arrhythmia, residual shunt over decades) are outside these records' follow-up; defects with deficient rims, primum or sinus venosus anatomy, and very large defects remain surgical territory.

Source: Synthesis of the carded records above (PMIDs 12039500, 10504632). Registry IDs: none stated in either record.