SourceMed · Shelf #12275 in the ask interface
Self-gripping versus sutured mesh in open Lichtenstein inguinal hernia repair: recurrence and chronic groin pain no different, operating time 7.85 minutes shorter with self-gripping mesh in a synthesis of 17 studies (documented N = 3,722 patients)
Shelf #12275 · Liver & gut
POSSIBLE (the treatment made no difference)
Stamped: 2026-11-28.
Evidence published: 2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients having open Lichtenstein inguinal hernia repair, does self-gripping mesh, compared with sutured mesh fixation, reduce recurrence or chronic groin pain?
Balance of the evidence
POSSIBLE (the treatment made no difference) — one synthesis of 12 randomised trials and 5 cohort studies (3,722 patients) in open Lichtenstein repair: recurrence (odds ratio 0.66 relative, 95% CI 0.18 to 2.44) and chronic groin pain (odds ratio 0.75 relative, 95% CI 0.54 to 1.05) did not differ significantly between self-gripping and sutured mesh, and infection, haematoma and urinary retention were comparable; the only established difference is operating time, 7.85 minutes shorter with self-gripping mesh — a process gain the authors state cannot justify routine use. The record names no single mesh product or manufacturer, and none is named here. The stamp is POSSIBLE and.
MeSH: Hernia, Inguinal / surgery * · Herniorrhaphy / methods * · Humans · Surgical Mesh * · Suture Techniques *
Cards (2)
Card 1 — Self-gripping versus sutured mesh, 2017 synthesis: recurrence and chronic groin pain no different; operating time 7.85 minutes shorter with self-gripping mesh, across 3,722 patients
Study: Systematic review and meta-analysis (17 studies, 3,722 patients)
Population: Systematic review and meta-analysis comparing self-gripping mesh with sutured mesh fixation in open Lichtenstein inguinal hernia repair: 12 randomised controlled trials and 5 cohort studies, 3,722 patients. The record names no single mesh product or manufacturer, and none is named here.
Summary: Self-gripping versus sutured mesh, 2017 synthesis: recurrence and chronic groin pain no different; operating time 7.85 minutes shorter with self-gripping mesh, across 3,722 patients
Result: Recurrence did not differ significantly (odds ratio 0.66 relative, 95% CI 0.18 to 2.44; P = .54), nor did postoperative chronic groin pain (odds ratio 0.75 relative, 95% CI 0.54 to 1.05; P = .09). Operating time was shorter with self-gripping mesh (mean difference −7.85 minutes, 95% CI −9.94 to −5.76; P < .0001). Infection (odds ratio 0.81 relative), haematoma (odds ratio 0.97 relative) and urinary retention (odds ratio 0.66 relative) were comparable. The authors conclude that neither fixation technique is favoured on recurrence or chronic pain, and that the shorter operating time cannot justify routine use of self-gripping mesh.
Watch out: Five of the 17 studies are cohorts, follow-up is short for a recurrence question, and the chronic-pain interval (0.54 to 1.05) only just includes no effect — a small pain advantage is not excluded, it is not demonstrated.
Source: Ismail A, Abushouk AI, Elmaraezy A, Abdelkarim AH et al.. Self-gripping versus sutured mesh fixation methods for open inguinal hernia repair: A systematic review of clinical trials and observational studies. Surgery. 2017. PMID: 28249738. Registry ID: none stated in the record. MeSH: Hernia, Inguinal / surgery * · Herniorrhaphy / methods * · Humans · Surgical Mesh * · Suture Techniques *
Card 2 — Synthesis: self-gripping fixation made no demonstrated difference to recurrence or chronic pain — its only established gain is about 8 minutes of operating time
Study: Synthesis
Population: The carded record: one synthesis of 12 randomised trials and 5 cohort studies; total documented N = 3,722 patients.
Summary: Synthesis: self-gripping fixation made no demonstrated difference to recurrence or chronic pain — its only established gain is about 8 minutes of operating time
Result: The stamp is POSSIBLE (the treatment made no difference), Tier C, for the patient outcomes the fixation choice is meant to affect. Glue versus tack/staple fixation in laparoscopic repair is #12122 and lightweight versus heavyweight mesh is #12123 — different fixation and mesh questions.
Watch out: Laparoscopic (TEP/TAPP) fixation is outside this record: every pooled study is an open Lichtenstein repair.
Source: Synthesis of the carded record above (PMID 28249738). Registry ID: none stated in the record.