Travoprost intraocular implant versus timolol drops: pressure fell 6.6–8.5 mmHg on the implants versus 6.5–7.7 mmHg on timolol, noninferior at all 6 time points, with study-eye adverse events in 21.5–27.2% versus 10.8% (documented N = 590 patients)

Shelf #12282 · Eyes, skin, nose & allergy

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with open-angle glaucoma or ocular hypertension, does a single travoprost intraocular implant lower intraocular pressure as much as timolol 0.5% drops twice daily over 3 months?

Balance of the evidence

POSSIBLE (the treatment made no difference) — a single phase III randomised double-masked noninferiority trial (590 patients). One administration of the travoprost intraocular implant, in fast-eluting and slow-eluting models, lowered intraocular pressure by 6.6–8.5 mmHg over 3 months, statistically and clinically noninferior to timolol 0.5% drops twice daily (6.5–7.7 mmHg) at every measured time point. The trade is procedural: study-eye adverse events occurred in 21.5% and 27.2% of implant patients versus 10.8% on drops, including iritis in 5.1% on the slow-eluting model and one case of endophthalmitis. The record answers 3-month pressure equivalence only — not durability, not visual-field outcomes. The intracameral bimatoprost implant shelf (#9975) is the neighbouring sustained-release question for a different prostaglandin; drop-based questions sit on #2497 and #4023.

MeSH: Humans · Glaucoma, Open-Angle* / drug therapy / physiopathology · Intraocular Pressure* / drug effects / physiology · Ocular Hypertension* / drug therapy / physiopathology · Travoprost* / therapeutic use / administration & dosage · Antihypertensive Agents* / administration & dosage / therapeutic use / adverse effects · Female · Male · Double-Blind Method · Aged · Middle Aged · Drug Implants* · Tonometry, Ocular* · Treatment Outcome · Visual Acuity / physiology · Timolol / administration & dosage / therapeutic use / adverse effects · Ophthalmic Solutions · Aged, 80 and over · Adult

Cards (2)

Card 1 — GC-010 (2024): a single travoprost intraocular implant lowered pressure by 6.6–8.5 mmHg over 3 months — noninferior to twice-daily timolol drops in 590 patients

Study: Randomised controlled trial, phase III, double-masked, noninferiority (590 patients randomised)

Population: Phase III multicentre randomised double-masked sham-controlled noninferiority trial (GC-010): 590 patients with open-angle glaucoma or ocular hypertension (unmedicated mean diurnal pressure at least 21 mmHg and no reading above 36 mmHg) were randomised to a fast-eluting travoprost intraocular implant (200 patients), a slow-eluting implant (197) or timolol 0.5% drops twice daily (193). The primary outcome was mean change from baseline pressure at 08:00 and 10:00 on day 10, week 6 and month 3.

Summary: GC-010 (2024): a single travoprost intraocular implant lowered pressure by 6.6–8.5 mmHg over 3 months — noninferior to twice-daily timolol drops in 590 patients

Result: Mean pressure reduction across the 6 time points ranged from 6.6 to 8.4 mmHg with the fast-eluting implant, 6.6 to 8.5 mmHg with the slow-eluting implant and 6.5 to 7.7 mmHg with timolol; the upper limit of the 95% confidence interval for the implant-versus-timolol difference was under 1 mmHg at all 6 time points, meeting the primary endpoint. Study-eye adverse events were reported in 21.5% (fast-eluting), 27.2% (slow-eluting) and 10.8% (timolol), mostly mild or moderate; the commonest included iritis (0.5% fast-eluting, 5.1% slow-eluting), ocular hyperaemia (3.0% and 2.6%), reduced visual acuity (1.0%, 4.1% and 0.5% on timolol) and raised pressure (3.5%, 2.6% and 2.1%). One serious study-eye event (endophthalmitis) occurred.

Watch out: The efficacy window is only 3 months for a device intended to work far longer, and this is one of the programme's two phase III trials — the record itself says so. Adverse events were about twice as frequent with the implants as with drops, including one endophthalmitis.

Source: Sarkisian SR Jr, Ang RE, Lee AM, Berdahl JP et al.. Phase 3 Randomized Clinical Trial of the Safety and Efficacy of Travoprost Intraocular Implant in Patients with Open-Angle Glaucoma or Ocular Hypertension. Ophthalmology. 2024. PMID: 38423216. Registry ID: none stated in the record. MeSH: Humans · Glaucoma, Open-Angle* / drug therapy / physiopathology · Intraocular Pressure* / drug effects / physiology · Ocular Hypertension* / drug therapy / physiopathology · Travoprost* / therapeutic use / administration & dosage · Antihypertensive Agents* / administration & dosage / therapeutic use / adverse effects · Female · Male · Double-Blind Method · Aged · Middle Aged · Drug Implants* · Tonometry, Ocular* · Treatment Outcome · Visual Acuity / physiology · Timolol / administration & dosage / therapeutic use / adverse effects · Ophthalmic Solutions · Aged, 80 and over · Adult

Card 2 — Synthesis: one phase III trial shows an implanted travoprost reservoir matches timolol drops for 3 months — equivalence on a surrogate endpoint, Tier C

Study: Synthesis

Population: The carded record: the GC-010 trial (590 randomised); total documented N = 590.

Summary: Synthesis: one phase III trial shows an implanted travoprost reservoir matches timolol drops for 3 months — equivalence on a surrogate endpoint, Tier C

Result: A single noninferiority trial cannot meet the two-trial LIKELY gate; the stamp records that pressure lowering made no difference against drops over the measured window, with device adverse events running higher.

Watch out: Durability beyond 3 months, repeat administration, and use in patients whose pressure is uncontrolled on drops are outside this record; the companion phase III trial is not carded here.

Source: Synthesis of the carded record above (PMID 38423216). Registry ID: none stated in the record.