SourceMed · Shelf #1231 in the ask interface
Cricoid pressure during rapid-sequence induction (IRIS)
Shelf #1231 · Emergency & first hours
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients undergoing rapid-sequence induction, does cricoid pressure prevent pulmonary aspiration compared with a sham procedure, without worsening laryngoscopic view?
Balance of the evidence
POSSIBLE: The one large randomised test (IRIS, 3,472 patients) could not settle the question either way: pulmonary aspiration was rare and nearly identical (0.6% with cricoid pressure versus 0.5% with a sham procedure; risk difference -0.06%, 95% CI -0.57 to 0.42), but the sham procedure FAILED its prespecified noninferiority test (upper limit of the one-sided 95% CI for relative risk 2.00, above the 1.50 margin; P=.14), so omitting cricoid pressure was not proven safe. Cricoid pressure did make intubation harder: Cormack-Lehane grade 3-4 views in 10% versus 5% (P<.001) and intubation over 30 seconds in 47% versus 40% (P<.001). A single trial with a failed noninferiority design and a very low event rate caps at POSSIBLE.
MeSH: Anesthesia/adverse effects,methods · Cricoid Cartilage/physiology · Double-Blind Method · Female · Humans · Intubation, Intratracheal/statistics & numerical data · Laryngoscopy/statistics & numerical data · Length of Stay/statistics & numerical data · Male · Middle Aged · Operative Time · Pneumonia, Aspiration/etiology · Pressure · Treatment Outcome
Cards (2)
Card 1 — IRIS 2019: aspiration was 0.6% with cricoid pressure versus 0.5% with sham — but sham failed noninferiority, and cricoid worsened the view
Study: Randomised, double-blind, noninferiority trial in 10 academic centres
Population: 3,472 patients undergoing anaesthesia with rapid-sequence induction, enrolled February 2014 to February 2017 and followed for 28 days or until discharge; mean (SD) age 51 (19) years and 1,777 (51%) were men.
Summary: IRIS 2019: aspiration was 0.6% with cricoid pressure versus 0.5% with sham — but sham failed noninferiority, and cricoid worsened the view
Result: The primary end point, pulmonary aspiration, occurred in 10 patients (0.6%) in the Sellick (cricoid pressure) group and 9 patients (0.5%) in the sham group. The upper limit of the one-sided 95% CI of relative risk was 2.00, exceeding the 1.50 noninferiority margin, so noninferiority of the sham procedure was NOT demonstrated (P=.14); the risk difference was -0.06% (two-sided 95% CI -0.57 to 0.42) in both intention-to-treat and per-protocol populations. Pneumonia, length of stay and mortality did not differ significantly, but Cormack-Lehane grade 3-4 views were more frequent with cricoid pressure (10% vs 5%; P<.001) and intubation took over 30 seconds more often (47% vs 40%; P<.001).
Watch out: A failed noninferiority test is not proof that cricoid pressure works: with aspiration under 1%, the trial cannot exclude either a small protective effect or none, and it excluded the highest-risk settings its authors name (pregnancy, outside the operating room).
Source: Birenbaum A et al. Effect of Cricoid Pressure Compared With a Sham Procedure in the Rapid Sequence Induction of Anesthesia: The IRIS Randomized Clinical Trial. JAMA Surg. 2019. PMID: 30347104. Registry ID: ClinicalTrials.gov NCT02080754, from the record's databank fields. MeSH: Anesthesia/adverse effects,methods · Cricoid Cartilage/physiology · Double-Blind Method · Female · Humans · Intubation, Intratracheal/statistics & numerical data · Laryngoscopy/statistics & numerical data · Length of Stay/statistics & numerical data · Male · Middle Aged · Operative Time · Pneumonia, Aspiration/etiology · Pressure · Treatment Outcome
Card 2 — Synthesis: one large trial, an unproven manoeuvre and an unproven omission — POSSIBLE
Study: Synthesis
Population: Synthesis of the card above: IRIS 2019 (3,472 patients undergoing rapid-sequence induction).
Summary: Synthesis: one large trial, an unproven manoeuvre and an unproven omission — POSSIBLE
Result: IRIS leaves cricoid pressure where the evidence found it: aspiration rates were 0.6% versus 0.5%, the sham strategy was not shown noninferior, and the manoeuvre measurably worsened laryngoscopic view (grade 3-4 in 10% vs 5%) and intubation time. The honest stamp is POSSIBLE — the trial neither vindicates routine cricoid pressure nor licenses abandoning it on safety grounds.
Watch out: Do not quote IRIS as 'cricoid pressure doesn't work' or as 'stopping it is dangerous': both readings exceed a noninferiority trial whose confidence interval for relative risk reached 2.00 on an outcome occurring in fewer than 1 in 150 patients.
Source: Synthesis of Birenbaum A et al. JAMA Surg. 2019. PMID: 30347104. Registry ID as on the individual card.