Distal embolic protection during saphenous vein graft stenting (SAFER): 30-day death, infarction, emergency bypass or target-lesion revascularisation in 9.6% versus 16.5% on a conventional guidewire, driven by fewer infarctions and less no-reflow (documented N = 801 randomised)

Shelf #12489 · Heart, vessels, blood pressure & clotting

POSSIBLE (benefit)

Stamped: 2026-11-28.

Evidence published: 2002.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients undergoing stenting of stenotic saphenous vein aorto-coronary bypass grafts, does use of a distal embolic protection device — a filter deployed beyond the lesion to trap atherosclerotic debris liberated during the procedure — reduce 30-day major adverse cardiac events compared with stenting over a conventional guidewire?

Balance of the evidence

POSSIBLE (benefit) — one multicentre randomised trial (801 patients) of stenting degenerated saphenous vein grafts over a distal embolic protection device versus a conventional guidewire: the 30-day composite of death, myocardial infarction, emergency bypass or target-lesion revascularisation occurred in 9.6% with protection versus 16.5% without (P = 0.004; the 42% reduction the paper reports is a relative reduction, with the absolute rates printed here), driven by myocardial infarction (8.6% versus 14.7%) and the no-reflow phenomenon (3% versus 9%). The stamp is Tier C: a single trial, against an active standard technique rather than placebo, from the bare-metal stent era, and the device it tested has since been superseded by later filter designs. This shelf answers only the vein-graft protection question; cerebral embolic protection during transcatheter aortic valve replacement is a separate question (ask-index #1172), and glycoprotein IIb/IIIa inhibition in vein graft intervention is not what was randomised here.

MeSH: Aged · Biomarkers / blood · Blood Vessel Prosthesis Implantation / adverse effects* · Coronary Angiography · Coronary Artery Bypass* / adverse effects · Creatine Kinase / blood · Creatine Kinase, MB Form · Demography · Disease-Free Survival · Embolism / etiology* · Embolism / prevention & control* · Female · Filtration / instrumentation · Graft Occlusion, Vascular / diagnosis · Graft Occlusion, Vascular / etiology · Graft Occlusion, Vascular / surgery* · Humans · Isoenzymes / blood · Male · Myocardial Infarction / blood · Myocardial Infarction / etiology · Myocardial Infarction / prevention & control* · Saphenous Vein / surgery · Saphenous Vein / transplantation · Stents · Treatment Outcome

Cards (2)

Card 1 — SAFER 2002: distal embolic protection cut the 30-day composite to 9.6% versus 16.5% during vein graft stenting — infarction 8.6% versus 14.7%, no-reflow 3% versus 9%

Study: Randomised controlled trial, multicentre (801 patients randomised)

Population: Multicentre randomised trial: 801 eligible patients undergoing stenting of stenotic saphenous vein aorto-coronary bypass grafts were assigned to stent placement over the shaft of a distal embolic protection device (406 patients) or over a conventional 0.014-inch angioplasty guidewire (395 patients). The primary end point was a composite of death, myocardial infarction, emergency bypass surgery, or target-lesion revascularisation by 30 days. Platelet glycoprotein IIb/IIIa receptor blockers were administered in 61% of patients.

Summary: SAFER 2002: distal embolic protection cut the 30-day composite to 9.6% versus 16.5% during vein graft stenting — infarction 8.6% versus 14.7%, no-reflow 3% versus 9%

Result: The primary composite end point occurred in 39 patients (9.6%) assigned to the embolic protection device versus 65 patients (16.5%) assigned to the control guidewire (P = 0.004) — a 42% relative reduction, with the absolute rates as printed. The difference was driven by myocardial infarction (8.6% versus 14.7%, P = 0.008) and the no-reflow phenomenon (3% versus 9%, P = 0.02). Among patients who received glycoprotein IIb/IIIa blockers, composite end points occurred in 10.7% with the protection device versus 19.4% without (P = 0.008).

Watch out: A single trial from the bare-metal stent era, and the specific balloon-occlusion-and-aspiration device tested is no longer the design in routine use; the result supports the principle of distal protection in vein grafts rather than any current product. The composite is driven by periprocedural infarction and no-reflow, not by mortality, which the trial was not powered to separate.

Source: Baim DS, Wahr D, George B et al. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation. 2002. PMID: 11901037. Registry ID: none stated in the record. MeSH: Aged · Biomarkers / blood · Blood Vessel Prosthesis Implantation / adverse effects* · Coronary Angiography · Coronary Artery Bypass* / adverse effects · Creatine Kinase / blood · Creatine Kinase, MB Form · Demography · Disease-Free Survival · Embolism / etiology* · Embolism / prevention & control* · Female · Filtration / instrumentation · Graft Occlusion, Vascular / diagnosis · Graft Occlusion, Vascular / etiology · Graft Occlusion, Vascular / surgery* · Humans · Isoenzymes / blood · Male · Myocardial Infarction / blood · Myocardial Infarction / etiology · Myocardial Infarction / prevention & control* · Saphenous Vein / surgery · Saphenous Vein / transplantation · Stents · Treatment Outcome

Card 2 — Synthesis: one randomised trial shows distal protection during vein graft stenting prevents about 7 major events per 100 procedures, mostly periprocedural infarctions — POSSIBLE benefit

Study: Synthesis

Population: The carded record: the SAFER trial (801 patients randomised). Total documented N = 801.

Summary: Synthesis: one randomised trial shows distal protection during vein graft stenting prevents about 7 major events per 100 procedures, mostly periprocedural infarctions — POSSIBLE benefit

Result: A single large trial with a clear composite result and a plausible mechanism (trapped embolic debris causing infarction and no-reflow) supports POSSIBLE (benefit); one trial against an active technique, in a superseded device generation, is not enough for a higher stamp.

Watch out: Native-vessel intervention and carotid or cerebral protection are different questions; nothing here tests protection in those settings.

Source: Synthesis of the carded record above (PMID 11901037). Registry ID: none stated in the record.