SourceMed · Shelf #12490 in the ask interface
Early prophylactic ICD after myocardial infarction (DINAMIT; IRIS): arrhythmic and sudden deaths fell in both trials, but deaths from other causes rose by as much, so all-cause mortality was unchanged (hazard ratios 1.08 and 1.04 relative) (documented N = 1,572 randomised across two trials)
Shelf #12490 · Heart, vessels, blood pressure & clotting
SPLIT — POSSIBLE (benefit) for arrhythmic death / POSSIBLE (the treatment made no difference) for all-cause mortality
Stamped: 2026-11-28.
Evidence published: 2004–2009.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients at high arrhythmic risk in the first weeks after an acute myocardial infarction — reduced ejection fraction with impaired autonomic function, or reduced ejection fraction with a fast resting heart rate or nonsustained ventricular tachycardia — does prophylactic implantation of a cardioverter-defibrillator reduce all-cause mortality compared with medical therapy alone?
Balance of the evidence
SPLIT — POSSIBLE (benefit) for arrhythmic death / POSSIBLE (the treatment made no difference) for all-cause mortality — two independent randomised open-label trials (1,572 patients randomised in total), concordant on both halves of the split. In DINAMIT (ICD 6–40 days after infarction, ejection fraction 0.35 or less with impaired autonomic function), all-cause mortality was 62 of 332 versus 58 of 342 patients (hazard ratio 1.08 relative, P = 0.66), while arrhythmic deaths fell from 29 to 12 (hazard ratio 0.42 relative) and nonarrhythmic deaths rose from 29 to 50 (hazard ratio 1.75 relative). In IRIS (ICD 5–31 days after infarction in patients meeting rate or arrhythmia criteria), 116 of 445 ICD patients and 117 of 453 controls died (hazard ratio 1.04 relative, P = 0.78); sudden cardiac deaths were 27 versus 60 (hazard ratio 0.55 relative) and nonsudden cardiac deaths 68 versus 39 (hazard ratio 1.92 relative). The stamp is Tier C: neither trial had a placebo or sham arm, and both were open-label. This shelf is confined to implantation in the first 40 days; prophylactic ICD therapy later after infarction, in established ischaemic cardiomyopathy, is a separate question (#11497).
MeSH: Adult · Aged · Arrhythmias, Cardiac / etiology · Arrhythmias, Cardiac / mortality · Arrhythmias, Cardiac / prevention & control* · Death, Sudden, Cardiac / epidemiology · Death, Sudden, Cardiac / prevention & control · Defibrillators, Implantable* · Female · Follow-Up Studies · Humans · Male · Middle Aged · Myocardial Infarction / complications · Myocardial Infarction / mortality · Myocardial Infarction / therapy* · Risk · Stroke Volume · Survival Analysis · Ventricular Dysfunction, Left / etiology · Cause of Death · Defibrillators, Implantable* / adverse effects · Proportional Hazards Models · Registries · Survival Rate · Time Factors
Cards (3)
Card 1 — DINAMIT 2004: ICD at 6–40 days after infarction did not reduce overall mortality (hazard ratio 1.08 relative) — arrhythmic deaths 12 versus 29 were offset by nonarrhythmic deaths 50 versus 29
Study: Randomised controlled trial, open-label (674 patients randomised)
Population: Randomised open-label trial (the Defibrillator in Acute Myocardial Infarction Trial): 674 patients were assigned 6 to 40 days after a myocardial infarction to ICD therapy (332 patients) or no ICD therapy (342 patients). Entry required a left ventricular ejection fraction of 0.35 or less and impaired cardiac autonomic function (depressed heart-rate variability or an elevated average 24-hour heart rate on Holter monitoring). The primary outcome was mortality from any cause; death from arrhythmia was a predefined secondary outcome. Mean follow-up was 30 months.
Summary: DINAMIT 2004: ICD at 6–40 days after infarction did not reduce overall mortality (hazard ratio 1.08 relative) — arrhythmic deaths 12 versus 29 were offset by nonarrhythmic deaths 50 versus 29
Result: There was no difference in overall mortality: 62 deaths in the ICD group and 58 in the control group (hazard ratio for death in the ICD group 1.08 relative; 95% confidence interval 0.76 to 1.55; P = 0.66). Deaths due to arrhythmia were 12 in the ICD group versus 29 in the control group (hazard ratio 0.42 relative; 95% confidence interval 0.22 to 0.83; P = 0.009), but deaths from nonarrhythmic causes were 50 versus 29 (hazard ratio 1.75 relative; 95% confidence interval 1.11 to 2.76; P = 0.02).
Watch out: Open-label with no sham procedure, and cause-of-death classification in an unblinded trial is exactly where attribution can drift; the trial's own interpretation is that fewer arrhythmic deaths were offset by more nonarrhythmic deaths, leaving total mortality unchanged.
Source: Hohnloser SH, Kuck KH, Dorian P et al. Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction. N Engl J Med. 2004. PMID: 15590950. Registry ID: none stated in the record. MeSH: Adult · Aged · Arrhythmias, Cardiac / etiology · Arrhythmias, Cardiac / mortality · Arrhythmias, Cardiac / prevention & control* · Death, Sudden, Cardiac / epidemiology · Death, Sudden, Cardiac / prevention & control · Defibrillators, Implantable* · Female · Follow-Up Studies · Humans · Male · Middle Aged · Myocardial Infarction / complications · Myocardial Infarction / mortality · Myocardial Infarction / therapy* · Risk · Stroke Volume · Survival Analysis · Ventricular Dysfunction, Left / etiology
Card 2 — IRIS 2009: ICD at 5–31 days after infarction again left overall mortality unchanged (116 versus 117 deaths) — sudden deaths 27 versus 60, nonsudden cardiac deaths 68 versus 39
Study: Randomised controlled trial, open-label, multicentre (898 patients randomised)
Population: Randomised prospective open-label multicentre trial: 62,944 unselected patients with myocardial infarction were registered, and 898 who met clinical risk criteria 5 to 31 days after the event were enrolled — an ejection fraction of 40% or less with a heart rate of 90 or more beats per minute on the first available electrocardiogram (602 patients), nonsustained ventricular tachycardia at 150 or more beats per minute on Holter monitoring (208 patients), or both (88 patients). Patients were assigned to an ICD (445) or medical therapy alone (453). Mean follow-up was 37 months.
Summary: IRIS 2009: ICD at 5–31 days after infarction again left overall mortality unchanged (116 versus 117 deaths) — sudden deaths 27 versus 60, nonsudden cardiac deaths 68 versus 39
Result: Overall mortality was not reduced: 116 patients in the ICD group and 117 in the control group died (hazard ratio 1.04 relative; 95% confidence interval 0.81 to 1.35; P = 0.78). Sudden cardiac deaths were fewer with the ICD (27 versus 60; hazard ratio 0.55 relative; 95% confidence interval 0.31 to 1.00; P = 0.049), but nonsudden cardiac deaths were more frequent (68 versus 39; hazard ratio 1.92 relative; 95% confidence interval 1.29 to 2.84; P = 0.001). Hazard ratios were similar across the three enrolment-criterion groups.
Watch out: As in DINAMIT, the trial was open-label and the sudden-versus-nonsudden split rests on cause-of-death adjudication; only 898 of 62,944 registered patients met the risk criteria, so the result applies to that selected high-risk minority, not to all post-infarction patients.
Source: Steinbeck G, Andresen D, Seidl K et al. Defibrillator implantation early after myocardial infarction. N Engl J Med. 2009. PMID: 19812399. Registry ID: NCT00157768. MeSH: Aged · Cause of Death · Death, Sudden, Cardiac / prevention & control · Defibrillators, Implantable* / adverse effects · Female · Follow-Up Studies · Humans · Male · Middle Aged · Myocardial Infarction / mortality · Myocardial Infarction / therapy* · Proportional Hazards Models · Registries · Risk · Survival Rate · Time Factors
Card 3 — Synthesis: two trials, one answer twice — early ICDs prevent arrhythmic deaths and lose the same number of patients to other causes, leaving all-cause mortality unchanged — SPLIT
Study: Synthesis
Population: The carded record: DINAMIT (674 randomised) and IRIS (898 randomised); total documented N = 1,572, independent trials, additive.
Summary: Synthesis: two trials, one answer twice — early ICDs prevent arrhythmic deaths and lose the same number of patients to other causes, leaving all-cause mortality unchanged — SPLIT
Result: Both trials show the same pattern with the same magnitudes: sudden or arrhythmic deaths roughly halved, nonsudden or nonarrhythmic deaths roughly doubled, total mortality a hazard ratio of 1.08 and 1.04 relative. The split stamp records both halves rather than averaging them away.
Watch out: The 40-day boundary is the whole question: these trials do not argue against ICD implantation later after infarction, which rests on different trials (#11497).
Source: Synthesis of the carded records above (PMIDs 15590950, 19812399). Registry ID: NCT00157768 (IRIS); DINAMIT's record states none.