SourceMed · Shelf #12495 in the ask interface

Cutting balloon for in-stent restenosis (RESCUT): 7-month binary restenosis 29.8% versus 31.4% with conventional balloon angioplasty — no difference in restenosis or clinical events, though balloon slippage was far less frequent (6.5% versus 25%) (documented N = 428 randomised)

Shelf #12495 · Heart, vessels, blood pressure & clotting

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2004.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with coronary in-stent restenosis, does cutting balloon angioplasty — a balloon carrying longitudinal micro-blades that score the restenotic tissue as it expands — reduce recurrent restenosis and clinical events compared with conventional balloon angioplasty?

Balance of the evidence

POSSIBLE (the treatment made no difference) — one multicentre randomised European trial (428 patients with all types of in-stent restenosis) of cutting balloon angioplasty versus conventional balloon angioplasty: at seven-month angiographic follow-up the binary restenosis rate was 29.8% with the cutting balloon versus 31.4% with the conventional balloon (P = 0.82), the pattern of recurrent restenosis was similar, and clinical events at seven months were also similar. The device did show procedural advantages — fewer balloons used, a trend to less additional stenting (3.9% versus 8.0%, P = 0.07), and much less balloon slippage (6.5% versus 25%, P < 0.01) — but none of these translated into less recurrent restenosis. The stamp is Tier C: a single active-comparator trial from the bare-metal stent era, before drug-eluting balloons and drug-eluting stents became the standard restenosis treatments.

MeSH: Angioplasty, Balloon / methods* · Angioplasty, Balloon, Coronary / methods* · Coronary Angiography · Coronary Restenosis / diagnostic imaging · Coronary Restenosis / mortality · Coronary Restenosis / pathology · Coronary Restenosis / therapy* · Europe · Female · Humans · Male · Middle Aged · Prospective Studies · Stents* · Treatment Outcome

Cards (2)

Card 1 — RESCUT 2004: cutting balloon did not reduce recurrent in-stent restenosis (29.8% versus 31.4% at 7 months) or clinical events in 428 randomised patients

Study: Randomised controlled trial, multicentre (428 patients randomised)

Population: Multicentre randomised prospective European trial: 428 patients with all types of in-stent restenosis (focal, multifocal, diffuse, proliferative) were assigned to cutting balloon angioplasty or conventional balloon angioplasty. In both groups most restenotic lesions were shorter than 20 mm, and restenotic stent length was similar (18.6 mm cutting balloon versus 18.3 mm conventional).

Summary: RESCUT 2004: cutting balloon did not reduce recurrent in-stent restenosis (29.8% versus 31.4% at 7 months) or clinical events in 428 randomised patients

Result: At seven-month angiographic follow-up, the binary restenosis rate was not different between the groups (cutting balloon 29.8%, conventional 31.4%; P = 0.82), with a similar pattern of recurrent restenosis, and clinical events at seven months were also similar. Procedurally, only one balloon was used in 82.3% of cutting-balloon cases versus 75% of conventional cases (P = 0.03); balloon slippage was less frequent with the cutting balloon (6.5% versus 25%, P < 0.01); and there was a trend toward less additional stenting (3.9% versus 8.0%, P = 0.07).

Watch out: The trial predates drug-eluting balloons and second-generation drug-eluting stents, so its null result answers the historical device question, not how restenosis should be treated now; the procedural advantages it found did not produce an angiographic or clinical benefit.

Source: Albiero R, Silber S, Di Mario C et al. Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: results of the Restenosis Cutting Balloon Evaluation Trial (RESCUT). J Am Coll Cardiol. 2004. PMID: 15028348. Registry ID: none stated in the record. MeSH: Angioplasty, Balloon / methods* · Angioplasty, Balloon, Coronary / methods* · Coronary Angiography · Coronary Restenosis / diagnostic imaging · Coronary Restenosis / mortality · Coronary Restenosis / pathology · Coronary Restenosis / therapy* · Europe · Female · Humans · Male · Middle Aged · Prospective Studies · Stents* · Treatment Outcome

Card 2 — Synthesis: the cutting balloon's procedural elegance — less slippage, fewer balloons — bought no reduction in recurrent restenosis in the one randomised trial — POSSIBLE (the treatment made no difference)

Study: Synthesis

Population: The carded record: the RESCUT trial (428 patients randomised). Total documented N = 428.

Summary: Synthesis: the cutting balloon's procedural elegance — less slippage, fewer balloons — bought no reduction in recurrent restenosis in the one randomised trial — POSSIBLE (the treatment made no difference)

Result: Restenosis rates were within 2 percentage points and clinical events were similar; the differences the trial did find were in how the procedure felt, not in what it achieved. A single active-comparator trial supports POSSIBLE (the treatment made no difference) for the restenosis question.

Watch out: Drug-eluting balloons and stents, not tested here, are the current restenosis comparators; this shelf closes the cutting-balloon-versus-plain-balloon question only.

Source: Synthesis of the carded record above (PMID 15028348). Registry ID: none stated in the record.