SourceMed · Shelf #12498 in the ask interface

Elective balloon pump before high-risk PCI (BCIS-1): major adverse events at discharge 15.2% with elective counterpulsation versus 16.0% without — no difference, though major procedural complications were fewer (1.3% versus 10.7%) (documented N = 301 randomised)

Shelf #12498 · Heart, vessels, blood pressure & clotting

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2010.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with severe left ventricular dysfunction (ejection fraction 30% or less) and extensive coronary disease undergoing high-risk percutaneous coronary intervention, does elective intra-aortic balloon counterpulsation inserted before the procedure reduce major adverse cardiac and cerebrovascular events compared with no planned balloon pump?

Balance of the evidence

POSSIBLE (the treatment made no difference) — one multicentre randomised trial (301 patients with an ejection fraction of 30% or less and extensive coronary disease, Jeopardy Score 8 or more of 12, treated in 17 United Kingdom centres): major adverse cardiac and cerebrovascular events at hospital discharge occurred in 15.2% of the elective balloon-pump group versus 16.0% of the no-planned-pump group (P = 0.85; odds ratio 0.94 relative), and all-cause mortality at 6 months was 4.6% versus 7.4% (P = 0.32). Major procedural complications were fewer with elective pump insertion (1.3% versus 10.7%, P < 0.001), while major or minor bleeding (19.2% versus 11.3%, P = 0.06) and access-site complications (3.3% versus 0%, P = 0.06) tended to be more frequent. The stamp is Tier C: a single trial, open-label by necessity. Balloon counterpulsation in infarct-related cardiogenic shock is a separate question (#1534), as is PCI versus medical therapy in severe ischaemic ventricular dysfunction (#4151).

MeSH: Aged · Angioplasty, Balloon, Coronary / adverse effects · Angioplasty, Balloon, Coronary / methods* · Coronary Artery Disease / therapy* · Female · Humans · Intra-Aortic Balloon Pumping / adverse effects · Intra-Aortic Balloon Pumping / methods* · Male · Middle Aged · Myocardial Infarction / etiology · Myocardial Infarction / mortality · Myocardial Revascularization / statistics & numerical data · Patient Discharge / statistics & numerical data · Prospective Studies · Risk Assessment · Stroke / etiology · Treatment Outcome · Ventricular Dysfunction, Left*

Cards (2)

Card 1 — BCIS-1 2010: elective balloon pump before high-risk PCI did not reduce major adverse events (15.2% versus 16.0% at discharge) in 301 patients with severe ventricular dysfunction

Study: Randomised controlled trial, open-label, multicentre (301 patients randomised)

Population: Prospective open multicentre randomised trial (the Balloon Pump-Assisted Coronary Intervention Study) in 17 United Kingdom tertiary centres, December 2005 to January 2009: 301 patients with severe left ventricular dysfunction (ejection fraction 30% or less) and extensive coronary disease (Jeopardy Score 8 or more of 12) were assigned to elective intra-aortic balloon pump insertion before percutaneous coronary intervention (151 patients) or no planned pump (150 patients); patients with contraindications to, or class I indications for, balloon pump therapy were excluded. The primary end point was major adverse cardiac and cerebrovascular events — death, acute myocardial infarction, cerebrovascular event, or further revascularisation — at hospital discharge (capped at 28 days).

Summary: BCIS-1 2010: elective balloon pump before high-risk PCI did not reduce major adverse events (15.2% versus 16.0% at discharge) in 301 patients with severe ventricular dysfunction

Result: The primary end point occurred in 15.2% (23 of 151) of the elective balloon-pump group and 16.0% (24 of 150) of the no-planned-pump group (P = 0.85; odds ratio 0.94 relative, 95% confidence interval 0.51 to 1.76). All-cause mortality at 6 months was 4.6% versus 7.4% (P = 0.32; odds ratio 0.61 relative). Fewer major procedural complications occurred with elective pump insertion (1.3% versus 10.7%, P < 0.001; odds ratio 0.11 relative), while major or minor bleeding occurred in 19.2% versus 11.3% (P = 0.06) and access-site complications in 3.3% versus 0% (P = 0.06).

Watch out: The trial excluded patients who already had a class I indication for a balloon pump, so it tests routine prophylactic use only; the procedural-complication advantage is a secondary endpoint in an open trial, set against a bleeding trend in the opposite direction.

Source: Perera D, Stables R, Thomas M et al. Elective intra-aortic balloon counterpulsation during high-risk percutaneous coronary intervention: a randomized controlled trial. JAMA. 2010. PMID: 20736470. Registry ID: NCT00910481; ISRCTN40553718. MeSH: Aged · Angioplasty, Balloon, Coronary / adverse effects · Angioplasty, Balloon, Coronary / methods* · Coronary Artery Disease / therapy* · Female · Humans · Intra-Aortic Balloon Pumping / adverse effects · Intra-Aortic Balloon Pumping / methods* · Male · Middle Aged · Myocardial Infarction / etiology · Myocardial Infarction / mortality · Myocardial Revascularization / statistics & numerical data · Patient Discharge / statistics & numerical data · Prospective Studies · Risk Assessment · Stroke / etiology · Treatment Outcome · Ventricular Dysfunction, Left*

Card 2 — Synthesis: routine balloon pump insertion before high-risk PCI changed neither discharge events nor 6-month mortality in the one randomised trial — POSSIBLE (the treatment made no difference)

Study: Synthesis

Population: The carded record: the BCIS-1 trial (301 patients randomised). Total documented N = 301.

Summary: Synthesis: routine balloon pump insertion before high-risk PCI changed neither discharge events nor 6-month mortality in the one randomised trial — POSSIBLE (the treatment made no difference)

Result: The primary endpoint differed by less than 1 percentage point (odds ratio 0.94 relative). Fewer major procedural complications with the pump and a bleeding trend against it are secondary findings in an open trial and do not move the stamp.

Watch out: Patients with an established indication for counterpulsation were excluded by design; the shock setting is a separate shelf (#1534).

Source: Synthesis of the carded record above (PMID 20736470). Registry IDs: NCT00910481; ISRCTN40553718.