SourceMed · Shelf #12570 in the ask interface

Permissive hypercapnia in extremely low birthweight infants (PHELBI): a higher carbon dioxide target did not reduce bronchopulmonary dysplasia or death — 36% versus 30% (documented N = 362 recruited)

Shelf #12570 · Children’s health

POSSIBLE (the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In extremely low birthweight infants who need mechanical ventilation, does targeting a higher partial pressure of carbon dioxide (permissive hypercapnia), compared with a lower target range, reduce bronchopulmonary dysplasia or death?

Balance of the evidence

POSSIBLE (the treatment made no difference) — one multicentre randomised trial (362 infants recruited; 359 analysed after three dropped out), stopped after an interim analysis. Bronchopulmonary dysplasia or death occurred in 65 of 179 infants (36%) on the higher carbon dioxide target versus 54 of 180 (30%) on the control target (P = 0.18); mortality (14% versus 11%), grade 3–4 intraventricular haemorrhage (15% versus 12%) and severe retinopathy (11% versus 14%) also did not differ. The control arm was itself slightly hypercapnic by historical standards, so the trial answers only whether pushing targets higher still helps — it does not. A single stopped trial keeps the stamp Tier C.

MeSH: Bronchopulmonary Dysplasia / blood / physiopathology / prevention & control* · Carbon Dioxide / blood* · Female · Gestational Age · Humans · Hydrogen-Ion Concentration · Hypercapnia / blood / physiopathology · Infant, Extremely Low Birth Weight / blood* / physiology · Infant, Extremely Premature / blood* / physiology · Infant, Newborn · Male · Partial Pressure · Respiration, Artificial / methods · Tidal Volume / physiology · Treatment Outcome

Cards (2)

Card 1 — PHELBI 2015: targeting pCO2 55–75 mm Hg over the first 14 days did not reduce bronchopulmonary dysplasia or death versus a 40–60 mm Hg target (36% versus 30%; P = 0.18)

Study: Randomised controlled trial, multicentre (362 infants recruited, 359 analysed)

Population: Randomised multicentre trial at 16 tertiary perinatal centres in Germany: 362 infants with birthweight 400–1,000 g and gestational age 23–28 weeks plus 6 days, intubated and ventilated within 24 hours of birth, were assigned to a high pCO2 target (55–65 mm Hg on days 1–3, 60–70 on days 4–6, 65–75 on days 7–14) or a control target (40–50, 45–55 and 50–60 mm Hg over the same periods); three dropped out, leaving 179 high-target and 180 control infants analysed. The trial was stopped after an interim analysis (n = 359). Cranial ultrasonograms were assessed centrally by a masked radiologist.

Summary: PHELBI 2015: targeting pCO2 55–75 mm Hg over the first 14 days did not reduce bronchopulmonary dysplasia or death versus a 40–60 mm Hg target (36% versus 30%; P = 0.18)

Result: Bronchopulmonary dysplasia or death: 65 of 179 (36%) on the high target versus 54 of 180 (30%) on control (P = 0.18). Mortality was 25 (14%) versus 19 (11%; P = 0.32), grade 3–4 intraventricular haemorrhage 26 (15%) versus 21 (12%; P = 0.30), and severe retinopathy 20 (11%) versus 26 (14%; P = 0.36). The authors conclude that higher pCO2 targets than the slightly hypercapnic control range do not confer increased lung-protection benefits.

Watch out: The trial stopped early at an interim analysis, and its control range was already mildly hypercapnic — the result does not test hypercapnia against strict normocapnia, and it does not license deliberately high carbon dioxide levels outside the ranges studied.

Source: Thome UH, Genzel-Boroviczeny O, Bohnhorst B et al.. Permissive hypercapnia in extremely low birthweight infants (PHELBI): a randomised controlled multicentre trial. Lancet Respir Med. 2015. PMID: 26088180. Registry ID: ISRCTN56143743 (stated in the record). MeSH: Bronchopulmonary Dysplasia / blood / physiopathology / prevention & control* · Carbon Dioxide / blood* · Female · Gestational Age · Humans · Hydrogen-Ion Concentration · Hypercapnia / blood / physiopathology · Infant, Extremely Low Birth Weight / blood* / physiology · Infant, Extremely Premature / blood* / physiology · Infant, Newborn · Male · Partial Pressure · Respiration, Artificial / methods · Tidal Volume / physiology · Treatment Outcome

Card 2 — Synthesis: one stopped multicentre trial found no benefit from higher carbon dioxide targets — POSSIBLE (the treatment made no difference), Tier C

Study: Synthesis

Population: The carded record: the PHELBI trial (362 recruited, 359 analysed); total documented N = 362 recruited, as the record states both figures.

Summary: Synthesis: one stopped multicentre trial found no benefit from higher carbon dioxide targets — POSSIBLE (the treatment made no difference), Tier C

Result: Within the ranges tested, pushing pCO2 targets higher did not protect the lung or the brain; every major outcome pointed nowhere. The stamp records no difference, not harm: no outcome was significantly worse on the high target either.

Watch out: Infants above 1,000 g birthweight and ventilation strategies that avoid intubation altogether are outside this record; volume-targeted ventilation is a separate question on its own shelf.

Source: Synthesis of the carded record above (PMID 26088180). Registry ID: ISRCTN56143743.