SourceMed · Shelf #1285 in the ask interface

Support surfaces for pressure-ulcer prevention (PRESSURE programme)

Shelf #1285 · Eyes, skin, nose & allergy

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2006–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients at risk of pressure ulcers, do alternating-pressure mattresses/systems prevent ulceration better than standard or overlay surfaces?

Balance of the evidence

PRESSURE 2 (2,029 high-risk inpatients) compared alternating-pressure mattresses with high-specification foam: at the primary 30-day post-treatment follow-up there was INSUFFICIENT evidence of a difference in time to a new category ≥2 pressure ulcer (hazard ratio 0.76 relative, 95% CI 0.56 to 1.04; P=0.089; absolute difference 2%); only the treatment-phase sensitivity analysis reached significance (hazard ratio 0.66 relative, 0.46 to 0.93; P=0.0176; absolute difference 2.6%). PRESSURE 1 (1,972 patients) compared alternating-pressure mattresses with alternating-pressure overlays and found no difference at all (new grade ≥2 ulcers in 10.3% versus 10.7%; difference 0.4%, −2.3 to 3.1; P=0.75). Small, time-limited advantages over foam at best: POSSIBLE.

MeSH: Pressure Ulcer/epidemiology,prevention & control · Beds/adverse effects · Bedding and Linens · Patient Satisfaction · Humans · Adult · Aged · Aged, 80 and over · Middle Aged · Female · Male

Cards (3)

Card 1 — PRESSURE 2 2019: alternating-pressure mattresses showed a small treatment-phase benefit over high-specification foam, but the primary follow-up analysis was not significant (HR 0.76; P=0.089)

Study: Multicentre, Phase III, open, parallel-group randomised controlled trial (full HTA report)

Population: 2,029 adult inpatients at high risk of pressure-ulcer development (acutely ill, bedfast/chairfast and/or with a category 1 ulcer or pain at a pressure-ulcer site), randomised at 42 UK secondary and community inpatient facilities to an alternating pressure mattress (1,016) or a high-specification foam mattress (1,013), for a maximum treatment phase of 60 days plus 30 days of post-treatment follow-up; the abstract does not state mean age or the sex mix.

Summary: PRESSURE 2 2019: alternating-pressure mattresses showed a small treatment-phase benefit over high-specification foam, but the primary follow-up analysis was not significant (HR 0.76; P=0.089)

Result: Of the 2,029 participants, 160 (7.9%) developed a new pressure ulcer of category 2 or worse. There was insufficient evidence of a difference between groups for time to new category ≥2 ulcer at the 30-day final follow-up (Fine and Gray model hazard ratio 0.76 relative, 95% CI 0.56 to 1.04; exact P=0.0890; 2% absolute difference). In the treatment-phase sensitivity analysis, 132 (6.5%) developed a new category ≥2 ulcer and the difference was statistically significant (hazard ratio 0.66 relative, 95% CI 0.46 to 0.93; P=0.0176; 2.6% absolute difference). There was no evidence of a difference for category ≥1 ulcers (hazard ratio 0.83 relative, 0.67 to 1.02) or category ≥3 ulcers (hazard ratio 0.81 relative, 0.40 to 1.62), or for healing of pre-existing category 2 ulcers. Health economic analysis showed alternating-pressure mattresses to be cost-effective compared with foam, with small cost differences and very small QALY gains. A lower-than-anticipated event rate limited the trial's power.

Watch out: The honest headline is the primary analysis — 'insufficient evidence of a difference' — with the significant result confined to a sensitivity analysis of the treatment phase; a low event rate (7.9% overall) means even 2,029 patients left the main question imprecisely answered. The trial's journal report (PMID 31709401) is the same trial and is fenced in the synthesis, not counted twice.

Source: Nixon J et al. Comparing alternating pressure mattresses and high-specification foam mattresses to prevent pressure ulcers in high-risk patients: the PRESSURE 2 RCT. Health Technol Assess. 2019. PMID: 31559948. Registry ID: ISRCTN ISRCTN01151335, from the record's databank fields. MeSH: Adult · Aged · Aged, 80 and over · Beds/adverse effects · Female · Humans · Inpatients · Male · Middle Aged · Pressure Ulcer/epidemiology,prevention & control · Prospective Studies · United Kingdom/epidemiology · Young Adult

Card 2 — PRESSURE 1 2006: alternating-pressure mattresses and overlays produced identical ulcer rates (10.3% vs 10.7%) in 1,972 patients

Study: Pragmatic, open, multicentre randomised controlled trial

Population: 1,972 people admitted to hospital as acute or elective patients at 11 hospitals in six NHS trusts, randomised to an alternating pressure mattress (982) or an alternating pressure overlay (990); the abstract does not state mean age or the sex mix.

Summary: PRESSURE 1 2006: alternating-pressure mattresses and overlays produced identical ulcer rates (10.3% vs 10.7%) in 1,972 patients

Result: Intention-to-treat analysis found no difference in the proportions of participants developing a new pressure ulcer of grade 2 or worse (10.7% overlay patients, 10.3% mattress patients; difference 0.4%, 95% confidence interval −2.3% to 3.1%, P=0.75). More overlay patients requested a change owing to dissatisfaction (23.3%) than mattress patients (18.9%, P=0.02).

Watch out: This trial compares two active alternating-pressure devices, not a device against foam or standard care: its null says the cheaper overlay performs like the full mattress, which is a purchasing result, not evidence that alternating pressure itself works.

Source: Nixon J et al. Randomised, controlled trial of alternating pressure mattresses compared with alternating pressure overlays for the prevention of pressure ulcers: PRESSURE (pressure relieving support surfaces) trial. BMJ. 2006. PMID: 16740530. Registry ID: ISRCTN ISRCTN78646179, from the record's databank fields. MeSH: Adult · Aged · Bedding and Linens · Humans · Middle Aged · Patient Satisfaction · Pressure Ulcer/prevention & control

Card 3 — Synthesis: the programme shows parity among active surfaces and, at most, a small on-treatment edge over foam — POSSIBLE

Study: Synthesis

Population: Synthesis of the cards above: PRESSURE 2 2019 (2,029 inpatients, vs high-specification foam) and PRESSURE 1 2006 (1,972 patients, mattress vs overlay). The PRESSURE 2 journal report (EClinicalMedicine 2019, PMID 31709401) is the same trial as the HTA report carded above and is fenced here, not counted as separate evidence.

Summary: Synthesis: the programme shows parity among active surfaces and, at most, a small on-treatment edge over foam — POSSIBLE

Result: Four thousand randomised patients across the programme yield a modest, carefully hedged answer: alternating-pressure mattresses may shave a couple of percentage points off ulcer incidence while the patient is on them compared with good foam, mattress and overlay formats are interchangeable, and patient comfort (fewer change requests on mattresses in PRESSURE 1) may be the most reliable difference. Prophylactic dressings (Shelf #1284) and repositioning schedules (Shelf #1286) are separate layers of prevention.

Watch out: Event rates this low (8–11%) mean absolute gains from any surface are small; the trials' own conclusion points to better targeting of expensive surfaces rather than wider use.

Source: Synthesis of Nixon J et al. Health Technol Assess. 2019. PMID: 31559948; Nixon J et al. BMJ. 2006. PMID: 16740530. Registry IDs as on the individual cards.