SourceMed · Shelf #1293 in the ask interface

Intraoperative cell salvage

Shelf #1293 · Heart, vessels, blood pressure & clotting

POSSIBLE

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2005.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients having surgery with expected blood loss, does intraoperative cell salvage reduce allogeneic transfusion versus standard care?

Balance of the evidence

POSSIBLE: The carded randomised test is small and single-specialty: 61 patients having off-pump coronary bypass were randomised to washed salvaged-blood autotransfusion or homologous blood only; the salvage group had a higher 24-hour haemoglobin (11.9 vs 10.5 g/dL; P=0.0007) and a lower frequency of homologous blood product use (5 of 30 versus 11 of 31) that did not reach significance (P=0.095), with no derangement of clotting measures, no excess bleeding or adverse events, and no significant cost difference. The direction favours salvage for transfusion sparing, but the carded evidence is one 61-patient trial with a transfusion-exposure surrogate, so the stamp is POSSIBLE and the shelf says so.

MeSH: Blood Transfusion, Autologous/economics · Coronary Artery Bypass, Off-Pump/economics · Hemoglobins/analysis · Intraoperative Period · Humans · Adult · Aged · Female · Male

Cards (2)

Card 1 — Murphy 2005: cell salvage after off-pump bypass raised 24-hour haemoglobin and modestly reduced donor-blood use (5/30 vs 11/31; P=0.095)

Study: Randomised controlled trial (single specialty: first-time off-pump coronary artery bypass grafting)

Population: 61 patients undergoing off-pump coronary artery bypass grafting, prospectively randomised to autotransfusion of washed salvaged red cells (30) or control — homologous blood only, given by unit protocols (31). The abstract does not state mean age or the sex mix.

Summary: Murphy 2005: cell salvage after off-pump bypass raised 24-hour haemoglobin and modestly reduced donor-blood use (5/30 vs 11/31; P=0.095)

Result: Patients in the autotransfusion group had a significantly higher 24-hour postoperative haemoglobin concentration (11.9 g/dL [SD 1.41]) than controls (10.5 g/dL [SD 1.37]) (mean difference 1.02 g/dL, 95% CI 0.44 to 1.60; P=0.0007), and a 20% reduction in the frequency of homologous blood product use (5 of 30 versus 11 of 31; P=0.095). Autotransfusion was not associated with derangement of thromboelastograph values or laboratory clotting measures (prothrombin time, activated partial thromboplastin time, fibrinogen), increased postoperative bleeding, fluid requirements, or adverse clinical events. Total operation, hospitalisation and management costs per patient did not differ significantly (median difference USD 1015.90, 95% CI −2260 to 206; P=0.11).

Watch out: Sixty-one patients in one operation type: the transfusion-sparing endpoint is a surrogate (exposure to donor blood, not a clinical outcome), the headline use difference was not statistically significant, and extrapolation to other operations or to unwashed salvage systems is beyond this record.

Source: Murphy GJ et al. Safety, efficacy, and cost of intraoperative cell salvage and autotransfusion after off-pump coronary artery bypass surgery: a randomized trial. J Thorac Cardiovasc Surg. 2005. PMID: 15999036. Registry ID: none in the record's databank fields. MeSH: Adult · Aged · Blood Transfusion, Autologous/economics · Coronary Artery Bypass, Off-Pump/economics · Coronary Disease/surgery · Female · Hemoglobins/analysis · Hemostasis, Surgical · Humans · Intraoperative Period · Male · Platelet Count

Card 2 — Synthesis: salvage spares donor blood in the carded trial, without a coagulopathy price — POSSIBLE

Study: Synthesis

Population: Synthesis of the card above: Murphy 2005 (61 patients, off-pump coronary bypass).

Summary: Synthesis: salvage spares donor blood in the carded trial, without a coagulopathy price — POSSIBLE

Result: The carded trial supports the mechanism claim — returning a patient's own washed red cells keeps haemoglobin higher and trends toward fewer donor units — without showing harm to clotting or a cost penalty. Larger salvage trials and syntheses exist across other surgical specialties; they are not carded on this shelf, and this shelf's stamp reflects the verified record in front of it. Tranexamic acid in coronary surgery (Shelf #1246) attacks the same blood-loss problem pharmacologically and is not re-carded here.

Watch out: A POSSIBLE built on one small trial is a statement about this shelf's verified evidence, not about the worldwide salvage literature; if the parent build wants the wider programme carded, it needs its own verified anchors.

Source: Synthesis of Murphy GJ et al. J Thorac Cardiovasc Surg. 2005. PMID: 15999036. Registry ID as on the individual card.