SourceMed · Shelf #1297 in the ask interface

Pathogen-reduced platelets (SPRINT and successors)

Shelf #1297 · Heart, vessels, blood pressure & clotting

POSSIBLE

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2004.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients receiving platelet transfusions for thrombocytopenia, do pathogen-reduced (amotosalen/UVA) platelets prevent bleeding as effectively as conventional platelets?

Balance of the evidence

POSSIBLE: The pivotal randomised trial (SPRINT, 645 thrombocytopenic patients) met its non-inferiority test on the bleeding endpoint: WHO grade 2 bleeding occurred in 58.5% on amotosalen/UVA pathogen-inactivated platelets versus 57.5% on conventional platelets, and grade 3 or 4 bleeding in 4.1% versus 6.1% (non-inferiority P=0.001), with fewer transfusion reactions (3.0% vs 4.4%; P=0.02). The price was platelet quality: 1-hour corrected count increments were lower (11.1 versus 16.0 ×10^3), the interval to the next transfusion shorter (1.9 versus 2.4 days), and more platelet transfusions were needed (8.4 versus 6.2). Bleeding-grade endpoints are surrogates for the outcomes that matter most, and a single pivotal trial caps the stamp at POSSIBLE.

MeSH: Platelet Transfusion/adverse effects · Hemorrhage/prevention & control · Thrombocytopenia/therapy · Furocoumarins/pharmacology · Photochemistry · Humans · Adult · Aged · Female · Male

Cards (2)

Card 1 — SPRINT 2004: pathogen-inactivated platelets were non-inferior for grade 2 bleeding (58.5% vs 57.5%) — but increments were lower and more transfusions were needed

Study: Randomised transfusion trial (pathogen-inactivated versus conventional platelets)

Population: 645 patients with thrombocytopenia (318 photochemically treated, 327 control) randomly assigned to receive pathogen-inactivated (amotosalen HCl plus UVA) or conventional platelets for up to 28 days. The abstract does not state mean age or the sex mix.

Summary: SPRINT 2004: pathogen-inactivated platelets were non-inferior for grade 2 bleeding (58.5% vs 57.5%) — but increments were lower and more transfusions were needed

Result: The primary endpoint, the incidence of WHO grade 2 bleeding during platelet support, was 58.5% with treated platelets versus 57.5% with control platelets, and grade 3 or 4 bleeding occurred in 4.1% versus 6.1% (both equivalent between groups; P=0.001 by non-inferiority). The mean 1-hour posttransfusion corrected count increment was lower with treated platelets (11.1 versus 16.0 ×10^3), as were the average days to next platelet transfusion (1.9 versus 2.4) and the number of platelet transfusions was higher (8.4 versus 6.2) (all P<0.001). Transfusion reactions were fewer following treated platelets (3.0% versus 4.4%; P=0.02).

Watch out: Non-inferiority was shown for a bleeding-grade surrogate in patients receiving prophylactic support; the trial simultaneously showed the treated platelets performed worse on every platelet-quality measure (increment, interval, number of transfusions) — 'as effective at preventing grade 2 bleeding, at the cost of more product' is the accurate summary.

Source: McCullough J et al. Therapeutic efficacy and safety of platelets treated with a photochemical process for pathogen inactivation: the SPRINT Trial. Blood. 2004. PMID: 15138160. Registry ID: none in the record's databank fields. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Blood Platelets/drug effects · Blood-Borne Pathogens · Child · Erythrocyte Transfusion · Female · Furocoumarins/pharmacology · Hemorrhage/prevention & control · Humans · Male · Middle Aged · Photochemistry · Platelet Transfusion/adverse effects · Prospective Studies · Thrombocytopenia/therapy

Card 2 — Synthesis: bleeding prevention preserved, platelet quality reduced — POSSIBLE

Study: Synthesis

Population: Synthesis of the card above: SPRINT 2004 (645 patients with thrombocytopenia).

Summary: Synthesis: bleeding prevention preserved, platelet quality reduced — POSSIBLE

Result: SPRINT supports pathogen-reduced platelets as haemostatically adequate for prophylactic support (grade 2 bleeding 58.5% vs 57.5%), with a real efficiency cost in count increments and transfusion frequency. Later pathogen-reduction trials and meta-analyses extend this record and are not carded here. Cold-stored platelets (Shelf #1298) are a different storage technology answering a surgical-bleeding question and are not re-carded here.

Watch out: The trial's purpose was infection-risk reduction technology assessment; it was not designed to show — and does not show — fewer transfusion-transmitted infections, an outcome too rare for a 645-patient trial.

Source: Synthesis of McCullough J et al. Blood. 2004. PMID: 15138160. Registry ID as on the individual card.