SourceMed · Shelf #1337 in the ask interface
Etonogestrel implant vs low-dose levonorgestrel IUS: continuation and bleeding
Shelf #1337 · Women’s health
POSSIBLE
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In women aged 18–35 choosing long-acting contraception, how do the etonogestrel implant and the 13.5 mg LNG-IUS compare on 12-month discontinuation and bleeding-related discontinuation?
Balance of the evidence
POSSIBLE: One open-label randomised trial (Apter 2016, 766 women aged 18-35 at 38 European centres) found the low-dose 13.5 mg levonorgestrel intrauterine system (LNG-IUS 8, releasing about 8 µg/day) had a lower 12-month discontinuation rate than the etonogestrel implant — 19.6% versus 26.8% (difference -7.2 percentage points, 95% CI -13.2 to -1.2) — driven mainly by bleeding-related discontinuation (3.2% vs 11.3%) and fewer adverse-event discontinuations (14.3% vs 21.8%); satisfaction with the bleeding pattern (60.9% vs 33.6%) and preference to continue the method (70.1% vs 58.5%) also favoured the IUS. The stamp is POSSIBLE: a single open-label trial whose outcomes are continuation and satisfaction (process outcomes a woman cannot be blinded to), and the IUS studied is the low-dose 13.5 mg device, not the 52 mg system.
MeSH: Intrauterine Devices, Medicated/adverse effects · Desogestrel/administration & dosage · Levonorgestrel/administration & dosage · Menstruation/drug effects · Patient Satisfaction · Humans · Female
Cards (2)
Card 1 — Apter 2016: 12-month discontinuation was lower with the 13.5 mg LNG-IUS than with the etonogestrel implant (19.6% vs 26.8%), driven by bleeding
Study: Randomised, open-label, phase III study (38 centres, six European countries)
Population: 766 healthy nulliparous and parous women aged 18-35 years at 38 centres in six European countries, randomised to the levonorgestrel intrauterine system LNG-IUS 8 (13.5 mg total content, average release about 8 µg/24 h in the first year; Jaydess/Skyla) or the etonogestrel subdermal implant (68 mg). Mean age is not stated in the abstract.
Summary: Apter 2016: 12-month discontinuation was lower with the 13.5 mg LNG-IUS than with the etonogestrel implant (19.6% vs 26.8%), driven by bleeding
Result: Twelve-month discontinuation rates were 19.6% in the LNG-IUS 8 group and 26.8% in the implant group; the -7.2 percentage point difference was statistically significant (95% CI -13.2 to -1.2). Fewer women in the LNG-IUS 8 group discontinued because of increased bleeding (3.2% vs 11.3%) or adverse events (14.3% vs 21.8%). At 12 months, more LNG-IUS 8 users were 'very/somewhat satisfied' with their bleeding pattern (60.9% vs 33.6%) and reported a preference to use their study treatment after study completion (70.1% vs 58.5%).
Watch out: Continuation is partly a preference outcome measured in women who know which device they have — exactly the outcome open-label design can move; and the intrauterine device here is the low-dose 13.5 mg system, so the bleeding profile should not be assumed identical to the 52 mg levonorgestrel IUS.
Source: Apter D et al. A 12-month multicenter, randomized study comparing the levonorgestrel intrauterine system with the etonogestrel subdermal implant. Fertil Steril. 2016. PMID: 27016644. Registry ID: ClinicalTrials.gov NCT01397097, from the record's databank fields (stated in the abstract). MeSH: Adolescent · Adult · Contraceptive Agents, Female/administration & dosage,adverse effects · Desogestrel/administration & dosage,adverse effects · Drug Implants · Europe · Female · Humans · Intrauterine Devices, Medicated/adverse effects · Levonorgestrel/administration & dosage,adverse effects · Menstruation/drug effects · Patient Satisfaction · Young Adult
Card 2 — Synthesis: in the only head-to-head trial, the low-dose IUS kept more users at one year, on bleeding tolerability — POSSIBLE
Study: Synthesis
Population: Synthesis of the card above: Apter 2016 (766 women aged 18-35).
Summary: Synthesis: in the only head-to-head trial, the low-dose IUS kept more users at one year, on bleeding tolerability — POSSIBLE
Result: Both methods are highly effective contraceptives; this shelf is about staying on them. The randomised difference is a 7.2-point lower discontinuation with the low-dose IUS at 12 months, mechanistically coherent (11.3% of implant users stopped for increased bleeding versus 3.2% of IUS users) and matched by satisfaction ratings. One trial, one device dose, one year: POSSIBLE.
Watch out: Discontinuation is not contraceptive failure: pregnancy rates are not the trial's reported primary outcome, and neither arm's efficacy is in question on this shelf — only tolerability-driven continuation.
Source: Synthesis of Apter D et al. Fertil Steril. 2016. PMID: 27016644. Registry ID as on the individual card.