SourceMed · Shelf #1534 in the ask interface
Intra-aortic balloon pump in MI complicated by cardiogenic shock (IABP-SHOCK II)
Shelf #1534 · Heart, vessels, blood pressure & clotting
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2011–2012.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with acute MI and cardiogenic shock undergoing early revascularisation, does intra-aortic balloon counterpulsation, compared with no balloon pump, reduce 30-day all-cause mortality?
Balance of the evidence
LIKELY (the treatment made no difference): IABP-SHOCK II (600 patients with MI and cardiogenic shock, all planned for early revascularisation) found 30-day all-cause mortality of 39.7% with intra-aortic balloon counterpulsation versus 41.3% without (RR 0.96 relative, 95% CI 0.79 to 1.17; P=0.69), with no differences in haemodynamic stabilisation, ICU stay, lactate, catecholamine dose or renal function, and no safety penalty or benefit. The companion programme trial CRISP-AMI — a different population (anterior STEMI WITHOUT shock) and a surrogate primary outcome (MRI infarct size) — was likewise null (infarct size 42.1% vs 37.5% of LV mass). The mortality null in shock rests on IABP-SHOCK II; CRISP-AMI is carded as programme support and labelled by its own population. The topic draft's claim of 'none at 6-year follow-up' refers to a later report not pinned at build and is fenced in the synthesis.
MeSH: Aged · Angioplasty, Balloon, Coronary · Coronary Artery Bypass · Female · Humans · Intention to Treat Analysis · Intra-Aortic Balloon Pumping · Male · Middle Aged · Myocardial Infarction · Practice Guidelines as Topic · Prospective Studies · Shock, Cardiogenic · Stents · Survival Rate · Treatment Failure
Cards (3)
Card 1 — IABP-SHOCK II 2012: balloon pump did not reduce 30-day mortality in MI with cardiogenic shock (39.7% vs 41.3%)
Study: Randomised, prospective, open-label, multicentre trial (Germany)
Population: 600 patients with cardiogenic shock complicating acute MI, randomly assigned to intra-aortic balloon counterpulsation (301) or no counterpulsation (299); all were expected to undergo early revascularisation (PCI or bypass surgery) and best available medical therapy; 300 and 298 patients were analysed for the primary end point. The abstract does not state mean age or sex mix.
Summary: IABP-SHOCK II 2012: balloon pump did not reduce 30-day mortality in MI with cardiogenic shock (39.7% vs 41.3%)
Result: At 30 days, 119 of 300 patients (39.7%) in the IABP group and 123 of 298 (41.3%) in the control group had died (RR 0.96 — a relative measure — 95% CI 0.79 to 1.17; P=0.69). There were no significant differences in secondary end points or process measures (time to haemodynamic stabilisation, ICU length of stay, serum lactate, catecholamine dose and duration, renal function), nor in major bleeding (3.3% vs 4.4%), peripheral ischaemic complications (4.3% vs 3.4%), sepsis (15.7% vs 20.5%), or stroke (0.7% vs 1.7%).
Watch out: Open-label, and the confidence interval (0.79 to 1.17, relative) cannot exclude a modest benefit — but the point estimate sits on the null and every process measure agrees, which is why the field read this trial as closing the routine-use question.
Source: Thiele H et al. Intraaortic balloon support for myocardial infarction with cardiogenic shock. The New England journal of medicine. 2012. PMID: 22920912. Registry ID: ClinicalTrials.gov NCT00491036, from the record's databank fields. MeSH: Aged · Angioplasty, Balloon, Coronary · Coronary Artery Bypass · Female · Humans · Intention to Treat Analysis · Intra-Aortic Balloon Pumping · Male · Middle Aged · Myocardial Infarction · Practice Guidelines as Topic · Prospective Studies · Shock, Cardiogenic · Stents · Survival Rate · Treatment Failure
Card 2 — CRISP-AMI 2011: balloon pump before PCI did not reduce infarct size in anterior STEMI without shock (42.1% vs 37.5% of LV mass)
Study: Open, multicentre, randomised controlled trial (30 sites, 9 countries)
Population: 337 patients with acute anterior STEMI WITHOUT cardiogenic shock, enrolled June 2009 to February 2011, randomly assigned to intra-aortic balloon counterpulsation initiated before primary PCI and continued at least 12 hours, versus primary PCI alone. The abstract does not state mean age or sex mix.
Summary: CRISP-AMI 2011: balloon pump before PCI did not reduce infarct size in anterior STEMI without shock (42.1% vs 37.5% of LV mass)
Result: Mean infarct size by cardiac MRI at 3 to 5 days was 42.1% (95% CI 38.7 to 45.6) of LV mass with IABC plus PCI versus 37.5% (34.3 to 40.8) with PCI alone (difference 4.6 percentage points, −0.2 to 9.4; P=0.06) — numerically larger, not smaller, with the pump. At 30 days there were no significant differences in major vascular complications (4.3% vs 1.1%; P=0.09) or major bleeding/transfusion (3.1% vs 1.7%). By 6 months, 3 patients (1.9%) in the IABC group and 9 (5.2%) in the PCI-alone group had died (P=0.12).
Watch out: A different question from the shelf's: no shock, a surrogate primary outcome, and a 6-month mortality count of 3 versus 9 patients that is far too small to read as a signal. The card supports the programme-level null; it does not bear on shock mortality. The record also notes the device strategy this trial's rationale rested on — infarct-size reduction seen in animal models — did not translate.
Source: Patel MR et al. Intra-aortic balloon counterpulsation and infarct size in patients with acute anterior myocardial infarction without shock: the CRISP AMI randomized trial. JAMA. 2011. PMID: 21878431. Registry ID: ClinicalTrials.gov NCT00833612, from the record's databank fields. MeSH: Aged · Angioplasty, Balloon · Female · Heart Ventricles · Humans · Intra-Aortic Balloon Pumping · Magnetic Resonance Imaging · Male · Middle Aged · Myocardial Infarction · Myocardial Reperfusion · Shock, Cardiogenic · Treatment Outcome
Card 3 — Synthesis: routine balloon counterpulsation does not save lives in infarct shock — LIKELY (the treatment made no difference)
Study: Synthesis
Population: Synthesis of the cards above: IABP-SHOCK II 2012 (600 patients with MI and cardiogenic shock) and CRISP-AMI 2011 (337 patients with anterior STEMI without shock).
Summary: Synthesis: routine balloon counterpulsation does not save lives in infarct shock — LIKELY (the treatment made no difference)
Result: The randomised programme is null at both ends: no mortality benefit where the device was a class I guideline therapy (shock), and no infarct-size benefit where its mechanism predicted one (pre-PCI placement without shock). Longer-term IABP-SHOCK II follow-up reports exist in the literature but were not pinned in this build and are fenced here, uncited.
Watch out: The null is for ROUTINE use in revascularised infarct shock; it does not address mechanical complications of MI (papillary muscle rupture, ventricular septal defect), where no randomised trial exists.
Source: Synthesis of Thiele H et al. The New England journal of medicine. 2012. PMID: 22920912; Patel MR et al. JAMA. 2011. PMID: 21878431. Registry IDs as on the individual cards.