Continuing versus interrupting oral anticoagulation for cardiac device surgery (BRUISE CONTROL programme)

Shelf #1547 · Heart, vessels, blood pressure & clotting

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2013–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients on warfarin or a direct oral anticoagulant undergoing pacemaker or defibrillator surgery, does continuing the anticoagulant, compared with interruption (with heparin bridging for warfarin), reduce clinically significant device-pocket haematoma?

Balance of the evidence

SPLIT — LIKELY that continued warfarin beats heparin bridging / LIKELY (the treatment made no difference) for continued versus interrupted DOAC: The two programme trials answer different halves of peri-device anticoagulation. BRUISE CONTROL-1 (681 patients analysed, annual thromboembolic risk ≥5%) found clinically significant device-pocket haematoma in 3.5% with continued warfarin versus 16.0% with heparin bridging (RR 0.19 relative, 95% CI 0.10 to 0.36) — the trial was stopped early at a prespecified interim analysis because the difference was so large. BRUISE CONTROL-2 (662 patients with AF and CHA2DS2-VASc ≥2 on a DOAC) found haematoma rates identical with continued versus interrupted DOAC (2.1% vs 2.1%; P=0.97), with complications uncommon (one stroke and one symptomatic pericardial effusion in each arm). Not Tier C: the claim is pocket haematoma, not death/MI/stroke.

MeSH: Administration, Oral · Aged · Anticoagulants · Atrial Fibrillation · Cardiac Pacing, Artificial · Dabigatran · Defibrillators, Implantable · Drug Administration Schedule · Female · Hematoma · Humans · Length of Stay · Male · Middle Aged · Postoperative Complications · Pyrazoles · Pyridones · Reoperation · Rivaroxaban · Thromboembolism

Cards (3)

Card 1 — BRUISE CONTROL-1 2013: operating on continued warfarin cut pocket haematoma five-fold versus heparin bridging (3.5% vs 16.0%)

Study: Randomised multicentre trial — terminated early on data and safety monitoring board recommendation after the second prespecified interim analysis

Population: Patients with an annual risk of thromboembolic events of 5% or more undergoing pacemaker or ICD surgery, randomly assigned to continued warfarin or bridging therapy with heparin; 343 (continued warfarin) and 338 (bridging) patients were analysed for the primary outcome. The abstract does not state mean age or sex mix.

Summary: BRUISE CONTROL-1 2013: operating on continued warfarin cut pocket haematoma five-fold versus heparin bridging (3.5% vs 16.0%)

Result: Clinically significant device-pocket haematoma (necessitating prolonged hospitalisation, interruption of anticoagulation, or further surgery) occurred in 12 of 343 (3.5%) patients in the continued-warfarin group versus 54 of 338 (16.0%) in the heparin-bridging group (RR 0.19 — a relative measure — 95% CI 0.10 to 0.36; P<0.001) — an absolute difference of 12.5 percentage points. Major surgical and thromboembolic complications were rare and did not differ significantly: one cardiac tamponade and one MI in the bridging group, one stroke and one TIA in the continued-warfarin group.

Watch out: Early termination at an interim analysis can exaggerate effect sizes, but a 12.5-point absolute gap with an interval of 0.10 to 0.36 (relative) leaves the direction in no doubt; this is the trial that rewrote device-surgery guidance toward continuing warfarin.

Source: Birnie DH et al. Pacemaker or defibrillator surgery without interruption of anticoagulation. The New England journal of medicine. 2013. PMID: 23659733. Registry ID: ClinicalTrials.gov NCT00800137, from the record's databank fields. MeSH: Aged · Anticoagulants · Defibrillators, Implantable · Female · Hematoma · Heparin · Humans · Incidence · Male · Pacemaker, Artificial · Perioperative Period · Thromboembolism · Warfarin

Card 2 — BRUISE CONTROL-2 2018: continuing a DOAC through device surgery gave the same haematoma rate as interrupting it (2.1% vs 2.1%)

Study: Randomised multicentre trial (primary outcome blindly evaluated)

Population: 662 patients with atrial fibrillation and CHA2DS2-VASc score of 2 or more undergoing device surgery, randomly assigned to continued (328) or interrupted (334) direct oral anticoagulant (dabigatran, rivaroxaban, or apixaban); median time between pre- and post-operative DOAC doses was 12 hours in the continued arm and 72 hours in the interrupted arm. The abstract does not state mean age or sex mix.

Summary: BRUISE CONTROL-2 2018: continuing a DOAC through device surgery gave the same haematoma rate as interrupting it (2.1% vs 2.1%)

Result: Clinically significant device-pocket haematoma (resulting in re-operation, interruption of anticoagulation, or prolonged hospital stay) occurred in 7 of 328 (2.1%; 95% CI 0.9 to 4.3) patients in the continued arm and 7 of 334 (2.1%; 0.9 to 4.3) in the interrupted arm (P=0.97). Complications were uncommon and included one stroke and one symptomatic pericardial effusion in each arm. The authors conclude either strategy might be reasonable in patients similar to those enrolled.

Watch out: The record's databank fields carry no registry ID for this trial (a DOI only) — stated here rather than filled from elsewhere. With 7 events per arm, the trial excludes large differences but not small ones; it does not test bridging for DOACs, which neither arm used.

Source: Birnie DH et al. Continued vs. interrupted direct oral anticoagulants at the time of device surgery, in patients with moderate to high risk of arterial thrombo-embolic events (BRUISE CONTROL-2). European heart journal. 2018. PMID: 30462279. Registry ID: none in the record's databank fields. MeSH: Administration, Oral · Aged · Anticoagulants · Atrial Fibrillation · Cardiac Pacing, Artificial · Dabigatran · Defibrillators, Implantable · Drug Administration Schedule · Female · Hematoma · Humans · Length of Stay · Male · Middle Aged · Postoperative Complications · Pyrazoles · Pyridones · Reoperation · Rivaroxaban · Thromboembolism

Card 3 — Synthesis: never bridge warfarin for device surgery; for DOACs, continuing or briefly interrupting are equivalent — SPLIT

Study: Synthesis

Population: Synthesis of the cards above: BRUISE CONTROL-1 2013 (681 patients analysed, warfarin) and BRUISE CONTROL-2 2018 (662 patients, DOACs).

Summary: Synthesis: never bridge warfarin for device surgery; for DOACs, continuing or briefly interrupting are equivalent — SPLIT

Result: The programme's combined message is that peri-device bleeding is driven by heparin exposure, not by the oral anticoagulant: continued warfarin beat bridging by 12.5 absolute points, and continued DOAC matched interrupted DOAC exactly. BRUISE CONTROL-1's PMID, unpinned in the topic draft, was pinned and verified at build (PMID 23659733).

Watch out: Both trials concern elective pacemaker/ICD procedures; extraction and lead-revision surgery carry higher bleeding risk and were not this programme's population.

Source: Synthesis of Birnie DH et al. The New England journal of medicine. 2013. PMID: 23659733; Birnie DH et al. European heart journal. 2018. PMID: 30462279. Registry IDs as on the individual cards.