SourceMed · Shelf #1623 in the ask interface

Perioperative levosimendan in cardiac surgery with low ejection fraction (LEVO-CTS, LICORN, CHEETAH)

Shelf #1623 · Heart, vessels, blood pressure & clotting

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with reduced ejection fraction undergoing cardiac surgery with cardiopulmonary bypass, or who need haemodynamic support after cardiac surgery, does levosimendan, compared with placebo, reduce death and major postoperative complications?

Balance of the evidence

LIKELY (the treatment made no difference) (Tier C: the composites include death and myocardial infarction, and one trial's primary outcome is mortality itself). Three randomised trials tested levosimendan around cardiac surgery and all three failed. LEVO-CTS (882 patients, EF 35% or less, prophylactic infusion): the four-component primary composite occurred in 24.5% versus 24.5% (adjusted OR 1.00; P=0.98). LICORN (336 patients, EF 40% or less, preoperative infusion): the low-cardiac-output-syndrome composite occurred in 52% versus 61% (adjusted difference −7%; P=0.15). CHEETAH (506 patients needing haemodynamic support after surgery): 30-day mortality 12.9% versus 12.8%, and the trial was stopped for futility. Small-trial meta-analyses had suggested a survival benefit; the three adequately sized trials refute it: LIKELY (the treatment made no difference).

MeSH: Aged · Cardiac Output, Low · Cardiac Surgical Procedures · Cardiotonic Agents · Double-Blind Method · Female · Heart-Assist Devices · Humans · Hydrazones · Infusions, Intravenous · Male · Middle Aged · Mortality · Myocardial Infarction · Perioperative Period · Postoperative Complications · Pyridazines · Renal Replacement Therapy · Simendan · Stroke Volume · Treatment Failure · Ventricular Dysfunction, Left

Cards (4)

Card 1 — LEVO-CTS 2017: prophylactic levosimendan in EF ≤35% — the primary composite was identical (24.5% vs 24.5%; OR 1.00; P=0.98)

Study: Randomised, placebo-controlled phase 3 trial

Population: 882 patients with left ventricular ejection fraction of 35% or less undergoing cardiac surgery with cardiopulmonary bypass were randomised; 849 received levosimendan (0.2 µg/kg/min for 1 hour, then 0.1 µg/kg/min for 23 hours, started before surgery) or placebo and formed the modified intention-to-treat population. The abstract does not state mean age or sex mix.

Summary: LEVO-CTS 2017: prophylactic levosimendan in EF ≤35% — the primary composite was identical (24.5% vs 24.5%; OR 1.00; P=0.98)

Result: The four-component primary end point (death through day 30, renal-replacement therapy through day 30, perioperative myocardial infarction through day 5, or mechanical cardiac assist device through day 5) occurred in 105 of 428 patients (24.5%) on levosimendan and 103 of 421 (24.5%) on placebo (adjusted odds ratio 1.00; 99% CI 0.66 to 1.54; P=0.98). The two-component end point (death or assist device) occurred in 13.1% versus 11.4% (adjusted OR 1.18; P=0.45). Adverse-event rates did not differ significantly.

Watch out: An odds ratio of exactly 1.00 on the primary composite in the largest prophylaxis trial leaves little room for a dosing or timing rescue of the hypothesis; the two companion trials tested the neighbouring questions and agree.

Source: Mehta RH et al. Levosimendan in Patients with Left Ventricular Dysfunction Undergoing Cardiac Surgery. The New England journal of medicine. 2017. PMID: 28316276. Registry ID: ClinicalTrials.gov NCT02025621, from the record's databank fields. MeSH: Aged · Cardiac Output, Low · Cardiac Surgical Procedures · Cardiotonic Agents · Double-Blind Method · Female · Heart-Assist Devices · Humans · Hydrazones · Infusions, Intravenous · Male · Middle Aged · Mortality · Myocardial Infarction · Perioperative Period · Postoperative Complications · Pyridazines · Renal Replacement Therapy · Simendan · Stroke Volume · Treatment Failure · Ventricular Dysfunction, Left

Estimate type: adjusted estimate, as stated in the card.

Card 2 — LICORN 2017: preoperative levosimendan did not significantly reduce low cardiac output syndrome (52% vs 61%; adjusted difference −7%, 95% CI −17 to 3; P=0.15)

Study: Randomised, double-blind, placebo-controlled trial

Population: 336 patients with left ventricular ejection fraction of 40% or less scheduled for isolated or combined CABG with cardiopulmonary bypass, at 13 French centres (mean age 68 years; 16% women); 167 received a 24-hour levosimendan infusion (0.1 µg/kg/min) begun after anaesthetic induction and 168 placebo; 333 completed the trial.

Summary: LICORN 2017: preoperative levosimendan did not significantly reduce low cardiac output syndrome (52% vs 61%; adjusted difference −7%, 95% CI −17 to 3; P=0.15)

Result: The primary composite — reflecting low cardiac output syndrome: catecholamine infusion still needed 48 hours after drug initiation, mechanical assist device need or failure to wean, or renal-replacement therapy at any time — occurred in 87 patients (52%) on levosimendan and 101 (61%) on placebo (absolute difference adjusted for centre, −7%; 95% CI −17% to 3%; P=0.15). No predefined subgroup (EF under 30%, surgery type, beta-blocker, balloon pump, or catecholamine use) showed an interaction. Hypotension (57% vs 48%) and atrial fibrillation (50% vs 40%) were numerically more frequent on levosimendan.

Watch out: LICORN is the smallest of the three trials and its confidence interval cannot exclude a modest benefit on its syndrome composite; it is carded as consistent with, not proof of, the class null — the weight of the shelf rests on LEVO-CTS and CHEETAH.

Source: Cholley B et al. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass: The LICORN Randomized Clinical Trial. JAMA. 2017. PMID: 28787507. Registry ID: EudraCT 2012-000232-25; ClinicalTrials.gov NCT02184819, from the record's databank fields. MeSH: Aged · Cardiac Output, Low · Cardiopulmonary Bypass · Cardiotonic Agents · Catecholamines · Coronary Artery Bypass · Double-Blind Method · Female · Heart-Assist Devices · Humans · Hydrazones · Infusions, Intravenous · Intention to Treat Analysis · Male · Middle Aged · Postoperative Complications · Premedication · Pyridazines · Renal Replacement Therapy · Simendan · Stroke Volume · Treatment Failure

Estimate type: adjusted estimate, as stated in the card.

Card 3 — CHEETAH 2017: levosimendan for haemodynamic support after cardiac surgery — 30-day mortality 12.9% vs 12.8%; stopped for futility

Study: Randomised, double-blind, placebo-controlled trial, stopped early for futility

Population: 506 patients in whom perioperative haemodynamic support was indicated after cardiac surgery by prespecified criteria; 248 received levosimendan (continuous infusion 0.025 to 0.2 µg/kg/min for up to 48 hours or ICU discharge) plus standard care and 258 placebo plus standard care. The abstract does not state mean age or sex mix.

Summary: CHEETAH 2017: levosimendan for haemodynamic support after cardiac surgery — 30-day mortality 12.9% vs 12.8%; stopped for futility

Result: The primary outcome, 30-day mortality, occurred in 32 patients (12.9%) on levosimendan and 33 (12.8%) on placebo (absolute risk difference 0.1 percentage points; 95% CI −5.7 to 5.9; P=0.97). Durations of mechanical ventilation, ICU stay, and hospital stay did not differ significantly, nor did rates of hypotension or cardiac arrhythmias. The trial was stopped for futility after 506 patients were enrolled.

Watch out: CHEETAH is the treatment (rather than prophylaxis) trial of the three, and its primary outcome is mortality itself: dead even. A futility stop on a mortality primary is the clearest of the three verdicts.

Source: Landoni G et al. Levosimendan for Hemodynamic Support after Cardiac Surgery. The New England journal of medicine. 2017. PMID: 28320259. Registry ID: ClinicalTrials.gov NCT00994825, from the record's databank fields. MeSH: Aged · Cardiac Output, Low · Cardiac Surgical Procedures · Cardiotonic Agents · Double-Blind Method · Female · Hemodynamics · Humans · Hydrazones · Infusions, Intravenous · Length of Stay · Male · Middle Aged · Mortality · Perioperative Period · Postoperative Complications · Pyridazines · Respiration, Artificial · Simendan · Stroke Volume · Treatment Failure

Card 4 — Synthesis: perioperative levosimendan does not improve outcomes in cardiac surgery — LIKELY (the treatment made no difference)

Study: Synthesis

Population: Synthesis of the cards above: LEVO-CTS 2017 (882 patients, prophylaxis in EF ≤35%), LICORN 2017 (336 patients, preoperative infusion in EF ≤40%), and CHEETAH 2017 (506 patients, treatment of postoperative haemodynamic compromise) — 1,724 randomised patients.

Summary: Synthesis: perioperative levosimendan does not improve outcomes in cardiac surgery — LIKELY (the treatment made no difference)

Result: Prophylaxis before surgery, infusion begun at induction, and rescue treatment after surgery: every position in the perioperative timeline has now been tested in an adequately sized blinded trial, and none improved the outcome it targeted. The earlier meta-analytic survival signal came from small trials and did not survive contact with these three.

Watch out: CHEETAH's primary outcome is 30-day mortality and is printed with absolute rates; the LEVO-CTS composite includes death and perioperative MI and is printed in full. No mortality claim is made for levosimendan.

Source: Synthesis of Mehta RH et al. The New England journal of medicine. 2017. PMID: 28316276, Cholley B et al. JAMA. 2017. PMID: 28787507, and Landoni G et al. The New England journal of medicine. 2017. PMID: 28320259. Registry IDs as on the individual cards.