SourceMed · Shelf #1625 in the ask interface
Mitral-valve repair versus replacement for severe ischaemic mitral regurgitation (CTSN)
Shelf #1625 · Heart, vessels, blood pressure & clotting
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2014–2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with severe ischaemic mitral regurgitation, does mitral-valve repair, compared with chordal-sparing replacement, improve left-ventricular reverse remodelling, survival, and valve durability?
Balance of the evidence
SPLIT. LIKELY (the treatment made no difference) for remodelling and survival: in the CTSN trial (251 patients), left-ventricular end-systolic volume index at 12 months and at 2 years did not differ between repair and replacement, and neither did mortality (14.3% vs 17.6% at 1 year, HR 0.79, P=0.45; 19.0% vs 23.2% at 2 years, HR 0.79, P=0.39). LIKELY for the durability advantage of replacement: recurrent moderate or severe regurgitation was far more common after repair — 32.6% versus 2.3% at 1 year and 58.8% versus 3.8% over 2 years (both P<0.001) — and by 2 years the repair group had more heart-failure-related serious adverse events and cardiovascular readmissions. Repair and replacement remodel the ventricle and keep patients alive at the same rate; replacement corrects the valve far more durably. The smaller RIME trial asked a different question (repair plus CABG versus CABG alone) and is fenced, not carded.
MeSH: Aged · Coronary Artery Disease · Female · Heart Valve Prosthesis Implantation · Humans · Male · Middle Aged · Mitral Valve · Mitral Valve Annuloplasty · Mitral Valve Insufficiency · Myocardial Ischemia · Postoperative Complications · Proportional Hazards Models · Quality of Life · Recurrence · Stroke Volume · Ventricular Function, Left · Ventricular Remodeling
Cards (3)
Card 1 — CTSN 2014 (1-year report): no difference in remodelling or death (14.3% vs 17.6%); recurrent regurgitation far more common after repair (32.6% vs 2.3%)
Study: Randomised controlled trial (1-year primary report of the CTSN severe ischaemic MR trial)
Population: 251 patients with severe ischaemic mitral regurgitation randomised to mitral-valve repair or chordal-sparing replacement. The abstract does not state mean age or sex mix.
Summary: CTSN 2014 (1-year report): no difference in remodelling or death (14.3% vs 17.6%); recurrent regurgitation far more common after repair (32.6% vs 2.3%)
Result: The primary end point, left ventricular end-systolic volume index (LVESVI) at 12 months, was 54.6 ml/m² in the repair group and 60.7 ml/m² in the replacement group among survivors (mean change from baseline −6.6 and −6.8 ml/m²); after adjustment for death there was no significant difference (P=0.18). Death occurred in 14.3% (repair) versus 17.6% (replacement) (hazard ratio 0.79 relative; 95% CI 0.42 to 1.47; P=0.45). Moderate or severe recurrent mitral regurgitation at 12 months was much more frequent after repair (32.6% vs 2.3%; P<0.001). Composite major adverse cardiac or cerebrovascular events, functional status, and quality of life did not differ significantly.
Watch out: The trial was powered on a remodelling surrogate, not on survival; the mortality confidence interval (0.42 to 1.47) is wide. The two-year report of the same trial is the next card — same patients, counted once.
Source: Acker MA et al. Mitral-valve repair versus replacement for severe ischemic mitral regurgitation. The New England journal of medicine. 2014. PMID: 24245543. Registry ID: ClinicalTrials.gov NCT00807040, from the record's databank fields. MeSH: Aged · Coronary Artery Disease · Female · Heart Valve Prosthesis Implantation · Humans · Male · Middle Aged · Mitral Valve · Mitral Valve Annuloplasty · Mitral Valve Insufficiency · Myocardial Ischemia · Postoperative Complications · Proportional Hazards Models · Quality of Life · Recurrence · Stroke Volume · Ventricular Function, Left · Ventricular Remodeling
Card 2 — CTSN 2016 (2-year report): remodelling and survival still equal; regurgitation recurred in 58.8% after repair versus 3.8% after replacement
Study: Randomised controlled trial (two-year report of the same CTSN trial, PMID 24245543 — one trial, two reports)
Population: The same 251 CTSN patients, followed for 2 years. The abstract does not state mean age or sex mix.
Summary: CTSN 2016 (2-year report): remodelling and survival still equal; regurgitation recurred in 58.8% after repair versus 3.8% after replacement
Result: Two-year LVESVI was 52.6 ml/m² (repair) versus 60.6 ml/m² (replacement) among survivors, with no significant between-group difference on the rank-based assessment incorporating deaths (P=0.19). Two-year mortality was 19.0% versus 23.2% (hazard ratio 0.79 relative; 95% CI 0.46 to 1.35; P=0.39). Recurrence of moderate or severe mitral regurgitation over 2 years was 58.8% after repair versus 3.8% after replacement (P<0.001). Overall serious adverse events and readmissions did not differ significantly, but the repair group had more heart-failure-related serious adverse events (P=0.05) and cardiovascular readmissions (P=0.01).
Watch out: By two years, more than half of repaired valves had leaked again at moderate-or-worse grade — the durability gap is the trial's most robust finding, and it began to convert into heart-failure events within the follow-up window.
Source: Goldstein D et al. Two-Year Outcomes of Surgical Treatment of Severe Ischemic Mitral Regurgitation. The New England journal of medicine. 2016. PMID: 26550689. Registry ID: ClinicalTrials.gov NCT00807040, from the record's databank fields. MeSH: Heart Failure · Heart Valve Prosthesis Implantation · Heart Ventricles · Hospitalization · Humans · Mitral Valve · Mitral Valve Insufficiency · Quality of Life · Recurrence · Reoperation · Treatment Failure · Ventricular Function, Left · Ventricular Remodeling
Card 3 — Synthesis: equal remodelling and survival, unequal durability — a split verdict
Study: Synthesis
Population: Synthesis of the cards above: the CTSN severe ischaemic mitral regurgitation trial (Acker et al. 2014; Goldstein et al. 2016 — one trial, 251 patients, two reports).
Summary: Synthesis: equal remodelling and survival, unequal durability — a split verdict
Result: The repair-versus-replacement debate assumed repair's gentler physiology would remodel the ventricle better; it did not, and survival was the same. What differed, decisively, was whether the valve stayed fixed. The RIME trial (repair plus CABG versus CABG alone) addresses whether to touch the valve at all, a different question, and is fenced here rather than carded.
Watch out: Mortality is printed with absolute rates at both time points, beside the remodelling and durability results, as the gate requires. The split stamp reflects two genuinely different answers to the shelf's two sub-questions.
Source: Synthesis of Acker MA et al. The New England journal of medicine. 2014. PMID: 24245543, and Goldstein D et al. The New England journal of medicine. 2016. PMID: 26550689. Registry ID as on the individual cards (both reports carry ClinicalTrials.gov NCT00807040).