SourceMed · Shelf #166 in the ask interface
Oxygen targets in critical illness: neither lower nor higher won
Shelf #166 · Critical care & sepsis
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2020–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In ICU patients on oxygen, does targeting a lower (conservative) oxygen level improve outcomes — or does liberal oxygen do harm the trials should catch?
Balance of the evidence
Both directions were tested at scale and both came back null. HOT-ICU's low vs high PaO₂ targets in hypoxemic respiratory failure: identical mortality. ICU-ROX's conservative vs usual oxygen in ventilated patients: identical ventilator-free days and survival. The wide middle is safe; the trials retire the anxiety at both ends — extremes, not targets, are where the harm lives (neither trial tested extreme hyperoxia).
MeSH: Adult · Aged · Conservative Treatment · Female · Humans · Hypoxia · Intensive Care Units · Kaplan-Meier Estimate · Male · Middle Aged · Oxygen · Oxygen Inhalation Therapy · Respiration, Artificial · Respiratory Distress Syndrome · Respiratory Insufficiency · Treatment Outcome · Ventilator Weaning
Cards (2)
Card 1 — HOT-ICU 2021: lower (60 mm Hg) vs higher (90 mm Hg) oxygen targets in hypoxemic respiratory failure — 90-day death 42.9% vs 42.4%.
Study: Randomized trial, ICUs in Europe
Population: 2,928 adults with acute hypoxemic respiratory failure receiving ≥10 L/min oxygen or FiO₂ ≥0.50
Summary: At 90 days, 42.9% (618/1441) in the lower-target group and 42.4% (613/1447) in the higher-target group had died (adjusted risk ratio 1.02, 95% CI 0.94–1.11; P=0.64). No difference in days alive without life support, and new ischemic episodes (shock, myocardial, stroke, intestinal) were similar between groups.
Result: At 90 days, 42.9% (618/1441) in the lower-target group and 42.4% (613/1447) in the higher-target group had died (adjusted risk ratio 1.02, 95% CI 0.94–1.11; P=0.64). No difference in days alive without life support, and new ischemic episodes (shock, myocardial, stroke, intestinal) were similar between groups.
Watch out: Targets were PaO₂-based and separation between arms was partial, as in all oxygen trials — but the confidence interval excludes any large mortality benefit for either direction. 'Lower is better' failed its biggest test; so did 'higher is safer.'
Source: Schjørring OL et al., N Engl J Med 2021 (PMID 33471452 · NCT03174002)
Estimate type: adjusted estimate, as stated in the card.
Card 2 — ICU-ROX 2020: conservative vs usual oxygen in ventilated patients — ventilator-free days 21.3 vs 22.1, no difference.
Study: Randomized trial, 21 ICUs in Australia and New Zealand
Population: 1,000 adults receiving mechanical ventilation in the ICU
Summary: Ventilator-free days to day 28 did not differ (median 21.3 conservative vs 22.1 usual; difference −0.3 days, 95% CI −2.1 to 1.6; P=0.80) despite the conservative group spending far more time on room air (median 29 vs 1 hour at FiO₂ 0.21). Mortality at 180 days: 35.7% vs 34.5% (odds ratio 1.05, 0.81–1.37).
Result: Ventilator-free days to day 28 did not differ (median 21.3 conservative vs 22.1 usual; difference −0.3 days, 95% CI −2.1 to 1.6; P=0.80) despite the conservative group spending far more time on room air (median 29 vs 1 hour at FiO₂ 0.21). Mortality at 180 days: 35.7% vs 34.5% (odds ratio 1.05, 0.81–1.37).
Watch out: Usual care in ANZ ICUs was already fairly conservative, narrowing the contrast — a trial of 'less vs moderate,' not 'less vs excess.' Read with Card 1: across designs and continents, the mortality curve over tested oxygen ranges is flat.
Source: ICU-ROX Investigators, N Engl J Med 2020 (PMID 31613432 · ACTRN12615000957594)