SourceMed · Shelf #1738 in the ask interface
Neutral-pH low-GDP peritoneal dialysis fluid (balANZ)
Shelf #1738 · Kidney, fluids & electrolytes
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2012.
Last source check: 2026-11-15.
Source correction status: no correction or retraction found at the last source check (2026-11-15).
Question
In incident peritoneal dialysis patients, does a neutral-pH, low-glucose-degradation-product solution preserve residual kidney function versus conventional acidic solution?
Balance of the evidence
SPLIT — balANZ (n=185) splits cleanly between its primary question and its secondary findings. On the shelf's question, the answer is no: the slope of GFR decline did not differ between biocompatible and conventional fluid (year 1: −0.22 versus −0.28 mL/min/1.73 m² per month, P=0.17; year 2: −0.09 versus −0.10, P=0.9) — POSSIBLE (the treatment made no difference) for preserving residual kidney function. On secondary outcomes, the biocompatible group had a longer time to anuria (P=0.009) and fewer peritonitis episodes (30% versus 49% of patients; 0.30 versus 0.49 episodes per year, P=0.01), confirmed in the trial's secondary microbiology analysis (IRR 0.61 relative) — POSSIBLE.
MeSH: Adult · Aged · Biocompatible Materials · Confidence Intervals · Cross-Over Studies · Dialysis Solutions · Female · Follow-Up Studies · Glomerular Filtration Rate · Glucose · Humans · Hydrogen-Ion Concentration · Kaplan-Meier Estimate · Kidney Failure, Chronic · Kidney Function Tests · Male · Middle Aged · Peritoneal Dialysis · Peritonitis · Reference Values · Risk Assessment · Severity of Illness Index · Survival Analysis · Time Factors · Treatment Outcome
Cards (3)
Card 1 — balANZ primary report: GFR decline slopes identical (P=0.17 and P=0.9); anuria delayed and peritonitis reduced
Study: Multicentre, open-label, parallel-group randomised controlled trial (2 years)
Population: 185 incident adult peritoneal dialysis patients with residual renal function, randomised to biocompatible (neutral-pH, low-glucose-degradation-product) or conventional solution for 2 years. The abstract does not print mean age or the sex split.
Summary: balANZ primary report: GFR decline slopes identical (P=0.17 and P=0.9); anuria delayed and peritonitis reduced
Result: The primary outcome — slope of renal function decline — did not differ: GFR slopes were −0.22 versus −0.28 mL/min/1.73 m² per month in year 1 (P=0.17) and −0.09 versus −0.10 in year 2 (P=0.9), biocompatible versus conventional. The biocompatible group had significantly longer times to anuria (P=0.009) and to first peritonitis (P=0.01), fewer patients developing peritonitis (30% versus 49%), and lower peritonitis rates (0.30 versus 0.49 episodes per year; P=0.01).
Watch out: Open-label, and the headline depends on the outcome chosen: the kidney-function question this shelf asks is answered null by the trial's own primary analysis, while the infection and anuria findings are secondary. Registry ID: none in this record's databank fields — stated, not filled.
Source: Johnson DW et al. Effects of biocompatible versus standard fluid on peritoneal dialysis outcomes. J Am Soc Nephrol. 2012. PMID: 22440906. Registry ID: none in the record's databank fields. MeSH: Adult · Aged · Biocompatible Materials · Confidence Intervals · Cross-Over Studies · Dialysis Solutions · Female · Follow-Up Studies · Glomerular Filtration Rate · Glucose · Humans · Hydrogen-Ion Concentration · Kaplan-Meier Estimate · Kidney Failure, Chronic · Kidney Function Tests · Male · Middle Aged · Peritoneal Dialysis · Peritonitis · Reference Values · Risk Assessment · Severity of Illness Index · Survival Analysis · Time Factors · Treatment Outcome
Card 2 — balANZ peritonitis analysis (same trial): rate ratio 0.61 relative; shorter peritonitis hospitalisations, milder episodes
Study: Secondary outcome analysis of the same randomised trial — same patients, counted once
Population: The balANZ safety population for peritonitis: 91 patients in each group, followed for 2 years on biocompatible or conventional solutions.
Summary: balANZ peritonitis analysis (same trial): rate ratio 0.61 relative; shorter peritonitis hospitalisations, milder episodes
Result: Unadjusted geometric mean peritonitis rates were 0.30 (95% CI 0.22 to 0.41) episodes per patient-year on biocompatible fluid versus 0.49 (0.39 to 0.62) on conventional fluid (IRR 0.61 relative, 0.41 to 0.90; p=0.01); the reduction was significant for non-pseudomonal Gram-negative peritonitis (IRR 0.41, 0.18 to 0.92; p=0.03) but not for culture-negative, Gram-positive, or polymicrobial episodes separately. Peritonitis-associated hospitalisation was not significantly reduced in odds (adjusted OR 0.80, 0.48 to 1.34) but was shorter (median 6 versus 11 days; p=0.05), and episodes were more often rated mild (37% versus 10%; p=0.001). Technique failures and peritonitis-related deaths were comparable.
Watch out: Its organism-level findings are exploratory subsets of the overall rate difference.
Source: Johnson DW et al. The effects of biocompatible compared with standard peritoneal dialysis solutions on peritonitis microbiology, treatment, and outcomes: the balANZ trial. Perit Dial Int. 2012. PMID: 22991015. Registry ID: none in the record's databank fields. MeSH: Adult · Anti-Bacterial Agents · Australia · Biocompatible Materials · Dialysis Solutions · Female · Hospitalization · Humans · Hydrogen-Ion Concentration · Kidney Failure, Chronic · Male · New Zealand · Peritoneal Dialysis · Peritoneum · Peritonitis · Survival Rate · Treatment Outcome
Estimate type: unadjusted estimate, as stated in the card.
Card 3 — Synthesis: no preservation of kidney function; a real peritonitis and anuria advantage — SPLIT as proposed
Study: Synthesis
Population: Synthesis of the cards above: balANZ primary report (Johnson 2012, JASN), 185 patients; balANZ peritonitis analysis (Johnson 2012, PDI), same trial.
Summary: Synthesis: no preservation of kidney function; a real peritonitis and anuria advantage — SPLIT as proposed
Result: Neutral-pH low-GDP fluid did not slow the loss of residual kidney function — the reason such fluids are marketed — but patients on it reached anuria later and had about two-fifths fewer peritonitis episodes (relative), with milder, shorter episodes when they occurred.
Watch out: One trial, open-label; the anuria and peritonitis findings are secondary outcomes and are stamped accordingly.
Source: Synthesis of Johnson DW et al. J Am Soc Nephrol. 2012 (PMID: 22440906) and Johnson DW et al. Perit Dial Int. 2012 (PMID: 22991015). Registry IDs as on the trial cards.