SourceMed · Shelf #1755 in the ask interface

Fixed versus dosimetry-calculated radioiodine activity in Graves' disease

Shelf #1755 · Thyroid & parathyroid

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with Graves' disease receiving radioiodine, does a fixed activity achieve cure rates comparable to dosimetry-calculated activity?

Balance of the evidence

MAYBE (weak evidence) — the only randomised comparison is a 40-patient single-centre trial that cannot carry the comparability claim made for it. Success of the first radioiodine dose at 3 months was 60% with a fixed activity versus 65% with dosimetry-calculated activity — 'no statistically significant difference' in a trial with 20 patients per arm is absence of evidence, not evidence of equivalence, and no non-inferiority margin was prespecified in the record. The authors' conclusion that the fixed approach 'may be used' as it is simpler goes beyond what their sample can show, and that overclaim is flagged rather than adopted.

MeSH: No MeSH terms in the record

Cards (2)

Card 1 — Jaiswal 2014: first-dose success 60% (fixed) versus 65% (calculated) at 3 months — in 40 patients

Study: Prospective, randomised, single-centre trial (3-month outcome)

Population: 40 patients with Graves' disease in an Indian population: 20 received a fixed activity of 185 MBq of iodine-131 and 20 received an activity calculated from gland weight and 24-hour uptake. The abstract does not print mean age or the sex split.

Summary: Jaiswal 2014: first-dose success 60% (fixed) versus 65% (calculated) at 3 months — in 40 patients

Result: Success of the first dose (euthyroid or hypothyroid at 3 months without further therapy) was 60% in the fixed group (8 hyperthyroid, 4 euthyroid, 8 hypothyroid after the first dose) versus 65% in the calculated group (7 hyperthyroid, 8 euthyroid, 5 hypothyroid). The record reports no statistically significant difference between the success rates.

Watch out: With 20 patients per arm, the confidence interval around a 5-point difference spans clinically important inferiority and superiority; the trial's conclusion that the fixed approach may be adopted for convenience overclaims its data and is flagged on this card. The record carries no MeSH terms and no registry ID, and follow-up is only 3 months — late hypothyroidism and retreatment are not captured.

Source: Jaiswal AK et al. Comparison of clinical outcome after a fixed dose versus dosimetry-based radioiodine treatment of Graves' disease: Results of a randomized controlled trial in Indian population. Indian J Endocrinol Metab. 2014. PMID: 25285281. Registry ID: none in the record. MeSH: the record carries no MeSH terms.

Card 2 — Synthesis: one 40-patient trial cannot establish comparability — MAYBE (weak evidence)

Study: Synthesis

Population: Synthesis of the card above: Jaiswal 2014, 40 patients.

Summary: Synthesis: one 40-patient trial cannot establish comparability — MAYBE (weak evidence)

Result: Fixed and calculated radioiodine activities produced similar crude success rates in the only randomised test, but the test is far too small to settle the question clinicians actually ask — whether fixed dosing is non-inferior.

Source: Synthesis of Jaiswal AK et al. Indian J Endocrinol Metab. 2014 (PMID: 25285281). Registry ID as on the trial card.