SourceMed · Shelf #1760 in the ask interface
Flash glucose monitoring in type 1 diabetes on multiple daily injections (IMPACT)
Shelf #1760 · Diabetes, glucose & metabolism
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2016–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with type 1 diabetes on multiple daily injections, does flash glucose monitoring reduce time in hypoglycaemia versus self-monitoring of blood glucose?
Balance of the evidence
LIKELY — one large multicentre trial, carded in its primary report and in the pre-specified MDI subgroup report that answers this shelf's question (counted once: they are the same trial). In IMPACT (n=241, well-controlled type 1 diabetes, HbA1c ≤7.5%), flash monitoring cut time in hypoglycaemia by 1.24 h/day versus SMBG overall (P<0.0001; a 38% relative reduction), and by 1.65 h/day (95% CI −2.21 to −1.09; P<0.0001) in the MDI subgroup of 163 patients — without deterioration in HbA1c. The population was well controlled at baseline, so the result addresses hypoglycaemia avoidance in people already at target, not glucose lowering in poorly controlled diabetes. Single trial, stated on the face of the shelf, but a large, consistent, precisely estimated one. Scope boundary: flash (intermittently scanned) monitoring is a distinct device class from the real-time CGM questions homed on Shelves #560/#561 and from the older-adult CGM question on Shelf #1762.
MeSH: Blood Glucose/analysis · Diabetes Mellitus, Type 1/blood/drug therapy · Drug Administration Schedule · Glycated Hemoglobin/metabolism · Humans · Hypoglycemia/prevention & control · Hypoglycemic Agents/therapeutic use · Insulin/therapeutic use · Inventions · Monitoring, Physiologic/methods
Cards (3)
Card 1 — IMPACT (primary report): flash monitoring cut time in hypoglycaemia by 1.24 h/day versus SMBG in well-controlled type 1 diabetes
Study: Multicentre, prospective, non-masked, randomised controlled trial (6 months) — primary report
Population: 241 adults with well-controlled type 1 diabetes (HbA1c ≤58 mmol/mol [7.5%]) at 23 European centres were randomised (120 flash glucose monitoring, 121 self-monitoring of blood glucose; outcomes evaluated in 239); both MDI and pump users were included, with randomisation stratified by type of insulin administration. The abstract does not print mean age or the sex split.
Summary: IMPACT (primary report): flash monitoring cut time in hypoglycaemia by 1.24 h/day versus SMBG in well-controlled type 1 diabetes
Result: Mean time in hypoglycaemia (<3.9 mmol/L (≈70 mg/dL)) changed from 3.38 h/day at baseline to 2.03 h/day at 6 months on flash monitoring (adjusted change −1.39) versus 3.44 to 3.27 h/day on SMBG (−0.14): a between-group difference of −1.24 h/day (SE 0.239; P<0.0001), equating to a 38% relative reduction. No device-related hypoglycaemia or safety issues were reported; 13 sensor-related adverse events occurred in ten participants (including allergy and insertion-site symptoms).
Watch out: Non-masked by design, in patients already well controlled — the trial shows hypoglycaemia can be trimmed without losing control; it does not show flash monitoring improves HbA1c, and its authors call for studies in less well-controlled and younger patients. The MDI-specific estimate is the subgroup report carded next.
Source: Bolinder J et al. Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial. Lancet. 2016. PMID: 27634581. Registry ID: ClinicalTrials.gov NCT02232698, from the record's databank fields. MeSH: Blood Glucose/analysis · Diabetes Mellitus, Type 1/blood/drug therapy · Drug Administration Schedule · Glycated Hemoglobin/metabolism · Humans · Hypoglycemia/prevention & control · Hypoglycemic Agents/therapeutic use · Insulin/therapeutic use · Inventions · Monitoring, Physiologic/methods
Estimate type: adjusted estimate, as stated in the card.
Card 2 — IMPACT MDI subgroup (pre-specified): time in hypoglycaemia fell by 1.65 h/day versus SMBG in injection users
Study: Pre-specified subgroup analysis of the IMPACT randomised trial (MDI users, 6 months)
Population: 163 IMPACT participants using multiple daily injections were randomised (82 flash monitoring, 81 SMBG); the full analysis set included 161 after one pregnancy exclusion in each group. Participants had type 1 diabetes for ≥5 years, HbA1c ≤7.5%, and had self-monitored ≥3 times daily before entry.
Summary: IMPACT MDI subgroup (pre-specified): time in hypoglycaemia fell by 1.65 h/day versus SMBG in injection users
Result: Mean time in hypoglycaemia fell by 46.0% in the intervention group (3.44 to 1.86 h/day; adjusted change −1.65 h/day) and was unchanged in controls (3.73 to 3.66 h/day; change 0.00): between-group difference −1.65 h/day (95% CI −2.21 to −1.09; P<0.0001). HbA1c did not deteriorate, treatment satisfaction and hypo/hyperglycaemia perception improved, and scanning averaged ~15 times daily while fingerstick testing fell from 5.5 to 0.5 tests/day. Four intervention participants withdrew because of sensor insertion/wear adverse events; no device-related hypoglycaemia or safety issues were reported.
Watch out: A subgroup report — carded second, under the primary report — though it is the report that answers this shelf's MDI-specific question and the subgroup was pre-specified. It inherits the parent trial's well-controlled population and 6-month horizon.
Source: Oskarsson P et al. Impact of flash glucose monitoring on hypoglycaemia in adults with type 1 diabetes managed with multiple daily injection therapy: a pre-specified subgroup analysis of the IMPACT randomised controlled trial. Diabetologia. 2018. PMID: 29273897. Registry ID: ClinicalTrials.gov NCT02232698, from the record's databank fields. MeSH: Adult · Blood Glucose/drug effects · Blood Glucose Self-Monitoring · Diabetes Mellitus, Type 1/blood/drug therapy · Female · Glycated Hemoglobin · Humans · Hypoglycemia/blood/drug therapy · Hypoglycemic Agents/administration & dosage/therapeutic use · Male · Middle Aged · Prospective Studies
Estimate type: adjusted estimate, as stated in the card.
Card 3 — Synthesis: flash monitoring halves hypoglycaemia exposure in well-controlled MDI users — LIKELY (single trial, two reports)
Study: Synthesis
Population: Synthesis of the cards above: IMPACT (Bolinder 2016), 241 patients overall; MDI subgroup (Oskarsson 2018), 163 patients — one trial, counted once.
Summary: Synthesis: flash monitoring halves hypoglycaemia exposure in well-controlled MDI users — LIKELY (single trial, two reports)
Result: For adults with type 1 diabetes on injections who are already near target, flash monitoring reduces time in hypoglycaemia by roughly 1.5 hours a day without worsening HbA1c, at the price of sensor-wear adverse events in a minority.
Watch out: Single trial: no second randomised trial of flash monitoring in MDI-treated type 1 diabetes is carded. Results do not extend to poorly controlled type 1 diabetes or to children.
Source: Synthesis of Bolinder J et al. Lancet. 2016 (PMID: 27634581) and Oskarsson P et al. Diabetologia. 2018 (PMID: 29273897). Registry ID NCT02232698 as on the trial cards.