Open-source automated insulin delivery versus sensor-augmented pump in type 1 diabetes (CREATE)
Shelf #1764 · Diabetes, glucose & metabolism
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In children and adults with type 1 diabetes, does open-source automated insulin delivery increase time in range versus sensor-augmented pump therapy?
Balance of the evidence
LIKELY — a clean randomised result for a community-built system: time in range (3.9–10.0 mmol/L (≈70–180 mg/dL)) during the final 2 weeks was 71.2% on open-source AID versus 54.5% on sensor-augmented pump, an adjusted between-group difference of 14 percentage points (95% CI 9.2 to 18.8; P<0.001), with no severe hypoglycaemia or diabetic ketoacidosis in either group over 24 weeks. Caveats on the face: 97 patients, an open-label trial of a highly motivated population willing to run open-source software, and a 24-week horizon — safety beyond that rests on community experience, not randomised data. Single trial. Scope boundary: commercial hybrid closed-loop systems are Shelf #561; CREATE is specifically the open-source question.
MeSH: Adolescent · Adult · Aged · Australia · Blood Glucose/analysis · Child · Diabetes Mellitus, Type 1/blood/drug therapy · Humans · Hypoglycemic Agents/administration & dosage · Infusion Pumps · Insulin/administration & dosage · Middle Aged · Young Adult
Cards (2)
Card 1 — CREATE: open-source AID raised time in range by 14 points versus sensor-augmented pump (71.2% vs 54.5%)
Study: Open-label, multicentre, randomised controlled trial (24 weeks)
Population: 97 patients with type 1 diabetes in New Zealand — 48 children (aged 7–15 years) and 49 adults (16–70 years) — were randomised to open-source AID (n=44) or sensor-augmented pump therapy (n=53). The abstract does not print mean age or the sex split.
Summary: CREATE: open-source AID raised time in range by 14 points versus sensor-augmented pump (71.2% vs 54.5%)
Result: During the final 2 weeks (days 155–168), mean time in range (glucose 3.9–10.0 mmol/L [70–180 mg/dl]) rose from 61.2% (SD 12.3) at baseline to 71.2% (12.1) on open-source AID and fell from 57.7% (14.3) to 54.5% (16.0) on sensor-augmented pump — an adjusted difference of 14.0 percentage points (95% CI 9.2 to 18.8; P<0.001), equivalent to 3 hours 21 minutes more per day in range. There was no difference in treatment effect by age group (P=0.56). No severe hypoglycaemia or diabetic ketoacidosis occurred in either group; two AID patients withdrew because of connectivity issues.
Watch out: Open-source means unregulated, community-supported software run on compatible hardware — participants who volunteer for such a trial are not a random sample of pump users, and the 24-week window cannot exclude rare safety events. The trial is registered as ACTRN12620000034932 (the record’s databank fields).
Source: Burnside MJ et al.; CREATE Trial Team. Open-Source Automated Insulin Delivery in Type 1 Diabetes. N Engl J Med. 2022. PMID: 36069869. Registry ID: ANZCTR ACTRN12620000034932, from the record’s databank fields. MeSH: Adolescent · Adult · Aged · Australia · Blood Glucose/analysis · Child · Diabetes Mellitus, Type 1/blood/drug therapy · Humans · Hypoglycemic Agents/administration & dosage · Infusion Pumps · Insulin/administration & dosage · Middle Aged · Young Adult
Estimate type: adjusted estimate, as stated in the card.
Card 2 — Synthesis: open-source AID outperformed sensor-augmented pumps on time in range — LIKELY (single trial)
Study: Synthesis
Population: Synthesis of the card above: CREATE (Burnside 2022), 97 patients.
Summary: Synthesis: open-source AID outperformed sensor-augmented pumps on time in range — LIKELY (single trial)
Result: A community-developed open-source algorithm matched the direction and size of benefit expected from automation, with no severe hypoglycaemia or DKA in 24 weeks.
Watch out: Single trial, in a self-selected population; long-term and real-world safety of open-source systems cannot be read off this shelf.
Source: Synthesis of Burnside MJ et al. N Engl J Med. 2022 (PMID: 36069869). Registry ID as on the trial card.