SourceMed · Shelf #2059 in the ask interface

Switching to biosimilar insulin glargine LY2963016 (ELEMENT 1 and 2): same control, same safety as originator glargine

Shelf #2059 · Diabetes, glucose & metabolism

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In type 1 and type 2 diabetes already treated with insulin glargine, does switching to the biosimilar insulin glargine LY2963016 at the same dose maintain glycaemic control and safety compared with staying on originator insulin glargine?

Balance of the evidence

For a biosimilar, 'no difference' is the success criterion, and that is what the randomised evidence shows. The carded report pools the prespecified subgroups of patients in the two ELEMENT trials who were already on originator insulin glargine before randomisation — 452 with type 1 diabetes in the 52-week open-label ELEMENT-1 and 299 with type 2 diabetes in the 24-week double-blind ELEMENT-2 — and who switched at equivalent doses either to the biosimilar LY2963016 insulin glargine (the specific tested product, named because identifying the exact biosimilar is the question) or stayed on originator glargine. No statistically significant treatment differences were found in efficacy or safety outcomes, apart from three isolated findings — weight change in type 1 diabetes, overall incidence of detectable insulin antibodies in type 2 diabetes, and serious adverse events in type 2 diabetes — which were not consistent across both studies or in the total populations and were judged not clinically meaningful. LIKELY (the treatment made no difference) — read here as demonstrated similarity, the intended result for a biosimilar switch (DOUBLE-A: the anchor report covers both randomised trials).

MeSH: Biosimilar Pharmaceuticals · Diabetes Mellitus, Type 1 · Diabetes Mellitus, Type 2 · Double-Blind Method · Glycated Hemoglobin · Humans · Hyperglycemia · Hypoglycemia · Hypoglycemic Agents · Insulin Glargine

Cards (2)

Card 1 — Hadjiyianni 2016 (ELEMENT-1 and ELEMENT-2 subgroups): no significant efficacy or safety differences between LY2963016 glargine and originator glargine after switching at equal doses

Study: Randomised controlled trials — combined subgroup report (ELEMENT-1 and ELEMENT-2)

Population: Subgroups of patients reporting prestudy originator insulin glargine treatment in two randomised trials: ELEMENT-1, a 52-week open-label study in type 1 diabetes (subgroup n=452; full trial 535), and ELEMENT-2, a 24-week double-blind study in type 2 diabetes (subgroup n=299; full trial 756). At randomisation, patients transitioned from prestudy glargine to equivalent doses of LY2963016 insulin glargine or originator insulin glargine. Primary efficacy: change in HbA1c from baseline to 24 weeks.

Summary: Hadjiyianni 2016 (ELEMENT-1 and ELEMENT-2 subgroups): no significant efficacy or safety differences between LY2963016 glargine and originator glargine after switching at equal doses

Result: No statistically significant treatment differences were identified for efficacy and safety outcomes except for weight change (type 1 diabetes), overall incidence of detectable insulin antibodies (type 2 diabetes), and serious adverse events (type 2 diabetes). These differences were neither consistently observed across both studies nor observed in the total study populations, and their magnitude suggests they were not clinically meaningful. The authors conclude that LY2963016 insulin glargine and originator insulin glargine show similar efficacy and safety profiles in patients reporting prestudy glargine treatment.

Watch out: This card reports the prestudy-glargine subgroups of the two trials rather than the full trial populations, and its abstract reports the similarity conclusion without arm-level HbA1c numbers — the claim carried is 'no significant differences found', not a precise equivalence margin. ELEMENT-1 was open-label.

Source: Hadjiyianni I et al. Efficacy and safety of LY2963016 insulin glargine in patients with type 1 and type 2 diabetes previously treated with insulin glargine. Diabetes Obes Metab. 2016. PMID: 26749289. No registry ID on this report's record. MeSH: Biosimilar Pharmaceuticals · Diabetes Mellitus, Type 1 · Diabetes Mellitus, Type 2 · Double-Blind Method · Glycated Hemoglobin · Humans · Hyperglycemia · Hypoglycemia · Hypoglycemic Agents · Insulin Glargine

Card 2 — Synthesis: switching to the biosimilar maintained control with no safety signal — LIKELY (the treatment made no difference)

Study: Synthesis

Population: 452 patients with type 1 diabetes (ELEMENT-1) and 299 with type 2 diabetes (ELEMENT-2) previously on originator glargine, switched at equivalent doses (Hadjiyianni 2016).

Summary: Synthesis: switching to the biosimilar maintained control with no safety signal — LIKELY (the treatment made no difference)

Result: No statistically significant differences in efficacy or safety between LY2963016 insulin glargine and originator insulin glargine, with three isolated, inconsistent exceptions judged not clinically meaningful. LIKELY (the treatment made no difference) — here, equivalence is the positive finding.

Watch out: The stamp wording is the library's null form because the trials found no difference between products; for a biosimilar switch that is the desired outcome, and the balance and this note say so explicitly so the stamp is not misread as a failed treatment.

Source: Synthesis of Hadjiyianni I et al. Diabetes Obes Metab. 2016 (PMID: 26749289), reporting the ELEMENT-1 and ELEMENT-2 trials.