SourceMed · Shelf #2100 in the ask interface

Machine perfusion versus cold storage for deceased-donor kidneys: hypothermic perfusion helps, a 1-hour normothermic add-on does not

Shelf #2100 · Kidney, fluids & electrolytes

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2009–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In deceased-donor kidney transplantation, does hypothermic machine perfusion of the graft reduce delayed graft function compared with static cold storage?

Balance of the evidence

The answer depends on which machine perfusion is meant. In the international paired trial (Moers 2009), one kidney from each of 336 deceased donors was randomised to hypothermic machine perfusion and the other to static cold storage: delayed graft function occurred in 70 recipients on machine perfusion versus 89 on cold storage (20.8% versus 26.5%; adjusted odds ratio 0.57, a relative effect), and 1-year graft survival was 94% versus 90%. In the later DCD trial (Hosgood 2023), adding just 1 hour of normothermic machine perfusion at the end of cold storage made no difference: delayed graft function was 60.7% with normothermic perfusion versus 58.5% with cold storage alone (adjusted odds ratio 1.13). So sustained hypothermic perfusion reduced delayed graft function, while a brief normothermic perfusion period after cold storage did not. SPLIT — LIKELY for hypothermic machine perfusion reducing delayed graft function / POSSIBLE (the treatment made no difference) for 1-hour normothermic perfusion added to cold storage — two large randomised trials, but testing two different perfusion strategies, so the verdict is split by technique rather than pooled.

MeSH: Delayed Graft Function · Humans · Kidney Transplantation · Organ Preservation · Perfusion · Tissue Donors

Cards (3)

Card 1 — Moers 2009: hypothermic machine perfusion cut delayed graft function (70 vs 89 cases) and improved 1-year graft survival (94% vs 90%)

Study: Randomised controlled trial (paired-kidney design)

Population: 672 recipients of kidneys from 336 consecutive deceased donors in an international randomised trial: one kidney from each donor was assigned to hypothermic machine perfusion and the paired kidney to static cold storage, with 1 year of follow-up. The primary end point was delayed graft function (dialysis required in the first week after transplantation).

Summary: Moers 2009: hypothermic machine perfusion cut delayed graft function (70 vs 89 cases) and improved 1-year graft survival (94% vs 90%)

Result: Delayed graft function developed in 70 patients in the machine-perfusion group versus 89 in the cold-storage group (20.8% versus 26.5%; adjusted odds ratio 0.57; P=0.01 — a relative effect, with the absolute rates given here). Machine perfusion also shortened delayed graft function, lowered serum creatinine in the first 2 weeks, and reduced graft failure (hazard ratio 0.52; P=0.03); 1-year allograft survival was 94% versus 90% (P=0.04). No serious adverse events were directly attributable to machine perfusion.

Watch out: The paired design is strong — each donor contributes one kidney to each arm — but the comparison is hypothermic perfusion for the whole preservation period, not a short perfusion episode added at the end. Effects on delayed graft function were clearer than effects on other secondary end points, most of which did not differ.

Source: Moers C et al. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med. 2009. PMID: 19118301. Registry ID: ISRCTN83876362, from the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cadaver · Cold Temperature · Creatinine / blood · Delayed Graft Function / blood · Delayed Graft Function / prevention & control · Graft Rejection · Humans · Kidney Transplantation* · Length of Stay · Middle Aged · Multivariate Analysis · Organ Preservation / methods* · Perfusion* · Proportional Hazards Models · Survival Analysis · Young Adult

Estimate type: adjusted estimate, as stated in the card.

Card 2 — Hosgood 2023: 1 hour of normothermic machine perfusion after cold storage did not reduce delayed graft function in DCD kidneys (60.7% vs 58.5%)

Study: Randomised controlled trial

Population: 338 kidneys from donation after circulatory death (DCD) donors randomised to static cold storage alone (n=168) or cold storage plus 1 hour of normothermic machine perfusion (n=170); 277 kidneys were included in the final intention-to-treat analysis. The primary end point was delayed graft function (dialysis in the first 7 days).

Summary: Hosgood 2023: 1 hour of normothermic machine perfusion after cold storage did not reduce delayed graft function in DCD kidneys (60.7% vs 58.5%)

Result: Delayed graft function occurred in 82 of 135 (60.7%) normothermic-perfusion kidneys versus 83 of 142 (58.5%) cold-storage kidneys (adjusted odds ratio 1.13, 95% CI 0.69 to 1.84; P=0.624 — a relative effect, with the absolute rates given here). Normothermic perfusion was not associated with more transplant thrombosis, infectious complications, or other adverse events, and was shown to be feasible and safe, but it did not reduce delayed graft function.

Watch out: This trial tests a different intervention from Moers: a single 1-hour normothermic episode at the end of cold storage, in DCD kidneys with a much higher baseline delayed-graft-function rate (~59%). Its null result does not overturn the hypothermic-perfusion finding, and its confidence interval (0.69 to 1.84, relative) cannot exclude a moderate benefit or harm.

Source: Hosgood SA et al. Normothermic machine perfusion versus static cold storage in donation after circulatory death kidney transplantation: a randomized controlled trial. Nat Med. 2023. PMID: 37231075. Registry ID: ISRCTN15821205, from the record. MeSH: Humans · Kidney · Kidney Transplantation* / methods · Organ Preservation / methods · Perfusion / methods · Tissue Donors

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Synthesis: hypothermic machine perfusion reduces delayed graft function; a brief normothermic add-on does not — SPLIT verdict

Study: Synthesis

Population: 672 paired deceased-donor kidney recipients (Moers 2009) and 277 DCD kidney transplants analysed (Hosgood 2023).

Summary: Synthesis: hypothermic machine perfusion reduces delayed graft function; a brief normothermic add-on does not — SPLIT verdict

Result: Hypothermic perfusion: delayed graft function 20.8% versus 26.5% (adjusted OR 0.57, relative), 1-year graft survival 94% versus 90%. One-hour normothermic perfusion after cold storage: 60.7% versus 58.5% (adjusted OR 1.13, relative). SPLIT — LIKELY for hypothermic machine perfusion / POSSIBLE (the treatment made no difference) for 1-hour normothermic perfusion.

Watch out: Do not pool these trials into a single 'machine perfusion works' claim: temperature, duration, and donor type all differ. The practical reading is about sustained hypothermic perfusion as the preservation method, not about any perfusion episode of any kind.

Source: Synthesis of Moers C et al. N Engl J Med. 2009 (PMID: 19118301) and Hosgood SA et al. Nat Med. 2023 (PMID: 37231075). Registry IDs as on the trial cards.

Estimate type: adjusted estimate, as stated in the card.