SourceMed · Shelf #2266 in the ask interface
Cryoballoon versus contact-force radiofrequency ablation: identical rhythm outcomes under continuous monitoring (CIRCA-DOSE)
Shelf #2266 · Heart, vessels, blood pressure & clotting
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In drug-refractory paroxysmal AF, do cryoballoon (4-minute or 2-minute freezes) and contact-force radiofrequency ablation differ in one-year arrhythmia recurrence measured by an implanted loop recorder?
Balance of the evidence
A three-way randomised comparison with the most honest rhythm ascertainment in the ablation literature — every patient carried an implantable loop recorder — and a flat result. CIRCA-DOSE randomised 346 patients with drug-refractory paroxysmal AF to contact-force radiofrequency (115), 4-minute cryoballoon (115), or 2-minute cryoballoon (116) ablation. One-year freedom from any atrial tachyarrhythmia (days 91–365) was 53.9%, 52.2%, and 51.7% respectively (P=0.87); freedom from symptomatic arrhythmia was 79.1%, 78.2%, and 73.3% (P=0.26); AF burden fell by a median of about 99% in all three groups (P=0.36). Serious adverse events did not differ significantly (2.6%, 5.3%, 6.0%; P=0.24). Radiofrequency took longer but used less fluoroscopy. LIKELY (the treatment — the energy source and freeze duration — made no difference): operator and anatomy, not energy, should drive the choice; and the 53% freedom figure under continuous monitoring is the honest benchmark against which intermittently monitored trials' higher success rates should be read.
MeSH: Aged · Atrial Fibrillation · Catheter Ablation · Cryosurgery · Female · Fluoroscopy · Humans · Longitudinal Studies · Male · Middle Aged · Treatment Outcome
Cards (2)
Card 1 — CIRCA-DOSE 2019: 1-year freedom from atrial tachyarrhythmia 53.9% (RF) vs 52.2% (Cryo-4) vs 51.7% (Cryo-2), P=0.87; AF burden down ~99% in all arms
Study: Randomised single-blinded three-arm trial (CIRCA-DOSE)
Population: 346 patients with drug-refractory paroxysmal AF at multiple centres, randomised to contact force-guided radiofrequency ablation (n=115), 4-minute cryoballoon ablation (n=115), or 2-minute cryoballoon ablation (n=116). All patients received an implantable loop recorder. Primary outcome: time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia between days 91 and 365, or repeat ablation at any time. Follow-up 12 months.
Summary: CIRCA-DOSE 2019: 1-year freedom from atrial tachyarrhythmia 53.9% (RF) vs 52.2% (Cryo-4) vs 51.7% (Cryo-2), P=0.87; AF burden down ~99% in all arms
Result: One-year freedom from atrial tachyarrhythmia: 53.9% (CF-RF), 52.2% (Cryo-4), 51.7% (Cryo-2) (P=0.87). Freedom from symptomatic atrial tachyarrhythmia: 79.1%, 78.2%, 73.3% (P=0.26). Median AF-burden reduction from baseline: 99.3%, 99.9%, 98.4% (P=0.36). Serious adverse events: 3 patients (2.6%), 6 (5.3%), 7 (6.0%) (P=0.24). The radiofrequency group had significantly longer procedure duration but significantly shorter fluoroscopy exposure (P<0.001 versus cryoballoon groups).
Watch out: Continuous monitoring detects recurrences that symptom-driven follow-up misses — cross-trial comparisons of 'success rates' without matching the monitoring method are meaningless. Paroxysmal, drug-refractory AF only.
Source: Andrade JG et al. Cryoballoon or Radiofrequency Ablation for Atrial Fibrillation Assessed by Continuous Monitoring: A Randomized Clinical Trial. Circulation. 2019. PMID: 31630538. Registry ID: NCT01913522, from the record. MeSH: Aged · Atrial Fibrillation · Catheter Ablation · Cryosurgery · Female · Fluoroscopy · Humans · Longitudinal Studies · Male · Middle Aged · Treatment Outcome
Card 2 — Synthesis: three energies, one outcome — LIKELY (no difference)
Study: Synthesis
Population: 346 patients with paroxysmal AF (Andrade 2019).
Summary: Synthesis: three energies, one outcome — LIKELY (no difference)
Result: Freedom from arrhythmia 51.7–53.9% across arms (P=0.87); burden reduction ~99% in all. LIKELY (the treatment made no difference).
Watch out: The shelf's second use is calibration: what ablation 'success' looks like when nobody is allowed to miss a recurrence.
Source: Synthesis of Andrade JG et al. Circulation. 2019 (PMID: 31630538). Registry ID as on the trial card.