SourceMed · Shelf #2271 in the ask interface
Pulsed field ablation versus thermal ablation for paroxysmal AF: noninferior at one year (ADVENT)
Shelf #2271 · Heart, vessels, blood pressure & clotting
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In drug-refractory paroxysmal AF, is pulsed field ablation noninferior to conventional thermal ablation (radiofrequency or cryoballoon) for effectiveness and safety at one year?
Balance of the evidence
THIN — one randomised trial, a clean noninferiority result, at one year. ADVENT randomised 607 patients with drug-refractory paroxysmal AF to pulsed field ablation (305) or conventional thermal ablation (302; radiofrequency or cryoballoon). The primary efficacy endpoint — freedom from initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation — was met in an estimated 73.3% with pulsed field versus 71.3% with thermal (difference 2.0 points; 95% Bayesian credible interval −5.2 to 9.2; posterior probability of noninferiority >0.999). Primary safety events were 2.1% versus 1.5% (difference 0.6 points; credible interval −1.5 to 2.8; noninferiority >0.999). LIKELY: pulsed field ablation is a noninferior alternative energy at one year in paroxysmal AF, from a single trial using Bayesian noninferiority analysis; claims of superiority — for safety rarities like oesophageal or phrenic injury, or for durability — are not established by this trial, whose event counts for such harms are far too small. (Desk note: the trial's sample size appears as 607 randomised in the record; some summaries cite 687 enrolled — the record governs.)
MeSH: Humans · Atrial Fibrillation · Bayes Theorem · Catheter Ablation · Pulmonary Veins · Recurrence · Single-Blind Method · Tachycardia · Treatment Outcome
Cards (2)
Card 1 — ADVENT 2023: efficacy success 73.3% (pulsed field) vs 71.3% (thermal); safety events 2.1% vs 1.5% — noninferior on both
Study: Randomised single-blind noninferiority trial (ADVENT)
Population: 607 patients with drug-refractory paroxysmal AF randomised 1:1 to pulsed field ablation (305) or conventional thermal ablation (radiofrequency or cryoballoon; 302). Primary efficacy endpoint: freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation at 1 year. Primary safety endpoint: acute and chronic device- and procedure-related serious adverse events. Bayesian noninferiority analysis.
Summary: ADVENT 2023: efficacy success 73.3% (pulsed field) vs 71.3% (thermal); safety events 2.1% vs 1.5% — noninferior on both
Result: The primary efficacy endpoint was met (no events) in 204 patients who underwent pulsed field ablation (estimated probability 73.3%) and 194 who underwent thermal ablation (71.3%) — between-group difference 2.0 percentage points (95% Bayesian credible interval −5.2 to 9.2; posterior probability of noninferiority >0.999). Primary safety endpoint events occurred in 6 patients (estimated incidence 2.1%) versus 4 (1.5%) (difference 0.6 points; 95% Bayesian credible interval −1.5 to 2.8; posterior probability of noninferiority >0.999). The authors conclude pulsed field ablation was noninferior to conventional thermal ablation on both endpoints at 1 year.
Watch out: Noninferiority within prespecified margins is not equivalence and not superiority; the rare-harm advantages claimed for pulsed field energy (oesophageal fistula, pulmonary vein stenosis, phrenic palsy) occur too infrequently for a 607-patient trial to settle. One year is short for durability comparisons.
Source: Reddy VY et al. Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation. N Engl J Med. 2023. PMID: 37634148. Registry ID: NCT04612244, from the record. MeSH: Humans · Atrial Fibrillation · Bayes Theorem · Catheter Ablation · Pulmonary Veins · Recurrence · Single-Blind Method · Tachycardia · Treatment Outcome
Card 2 — Synthesis: a noninferior new energy — LIKELY
Study: Synthesis
Population: 607 patients with paroxysmal AF (Reddy 2023).
Summary: Synthesis: a noninferior new energy — LIKELY
Result: Efficacy 73.3% vs 71.3% and safety 2.1% vs 1.5%, both noninferior (posterior probability >0.999). LIKELY.
Watch out: THIN — single trial; the shelf distinguishes 'noninferior at one year' from the broader claims made for the technology.
Source: Synthesis of Reddy VY et al. N Engl J Med. 2023 (PMID: 37634148). Registry ID as on the trial card.