SourceMed · Shelf #2295 in the ask interface

AV block with a weak ventricle: biventricular pacing beat right-ventricular pacing on death, heart-failure care, and remodelling (BLOCK HF)

Shelf #2295 · Heart, vessels, blood pressure & clotting

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2013.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with atrioventricular block, heart failure (NYHA I–III), and ejection fraction of 50% or less who need pacing, does biventricular pacing beat standard right-ventricular pacing?

Balance of the evidence

The trial that extended resynchronisation beyond wide-QRS heart failure to the pacing population itself. BLOCK HF enrolled patients with AV block and an indication for pacing, NYHA class I–III heart failure, and ejection fraction of 50% or less; all received a CRT pacemaker or defibrillator and were randomised to biventricular or standard right-ventricular pacing (691 randomised of 918 enrolled; average follow-up 37 months). The primary outcome — death from any cause, an urgent-care heart-failure visit requiring intravenous therapy, or a 15% or greater increase in left ventricular end-systolic volume index — occurred in 45.8% with biventricular pacing versus 55.6% with right-ventricular pacing (hazard ratio 0.74; 95% credible interval 0.60 to 0.90), with consistent results in the pacemaker and defibrillator subgroups. Left-ventricular lead complications occurred in 6.4% — the price of the extra lead. LIKELY (Tier C): when a patient with AV block and a reduced ejection fraction needs a device, pace both ventricles from the start rather than creating the dyssynchrony that heavy right-ventricular pacing causes. Note the composite leans partly on the remodelling component — the shelf reports the components' nature honestly rather than claiming a pure mortality result.

MeSH: Aged · Atrioventricular Block · Cardiac Resynchronization Therapy · Defibrillators, Implantable · Disease-Free Survival · Female · Heart Failure, Systolic · Hospitalization · Humans · Male · Middle Aged · Mortality · Pacemaker, Artificial · Stroke Volume · Treatment Outcome

Cards (2)

Card 1 — BLOCK HF 2013: primary outcome 45.8% (biventricular) vs 55.6% (right-ventricular) — HR 0.74; LV lead complications 6.4%

Study: Randomised controlled trial (BLOCK HF)

Population: 918 patients enrolled with AV block and a pacing indication, NYHA class I, II, or III heart failure, and left ventricular ejection fraction of 50% or less; 691 underwent randomisation to biventricular pacing or standard right-ventricular pacing via an implanted CRT pacemaker or ICD (ICD when defibrillation was indicated) and were followed for an average of 37 months. Primary outcome: time to death from any cause, an urgent-care visit for heart failure requiring intravenous therapy, or an increase of at least 15% in the left ventricular end-systolic volume index.

Summary: BLOCK HF 2013: primary outcome 45.8% (biventricular) vs 55.6% (right-ventricular) — HR 0.74; LV lead complications 6.4%

Result: The primary outcome occurred in 160 of 349 patients (45.8%) in the biventricular-pacing group versus 190 of 342 (55.6%) in the right-ventricular-pacing group; biventricular pacing was associated with a significantly lower incidence over time (hazard ratio 0.74; 95% credible interval 0.60 to 0.90), with similar results in the pacemaker and ICD subgroups. Left ventricular lead-related complications occurred in 6.4% of patients. The authors conclude biventricular pacing was superior to conventional right-ventricular pacing in this population. Funded by Medtronic.

Watch out: The composite includes a remodelling endpoint (end-systolic volume index) that favours resynchronisation by design; the trial does not report the death component separately in its abstract, so do not quote a mortality figure from this shelf. Bayesian analysis (credible interval) as designed.

Source: Curtis AB et al. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med. 2013. PMID: 23614585. Registry ID: NCT00267098, from the record. MeSH: Aged · Atrioventricular Block · Cardiac Resynchronization Therapy · Defibrillators, Implantable · Disease-Free Survival · Female · Heart Failure, Systolic · Hospitalization · Humans · Male · Middle Aged · Mortality · Pacemaker, Artificial · Stroke Volume · Treatment Outcome

Card 2 — Synthesis: pace both ventricles when AV block meets a weak ventricle — LIKELY

Study: Synthesis

Population: 691 randomised patients (Curtis 2013).

Summary: Synthesis: pace both ventricles when AV block meets a weak ventricle — LIKELY

Result: Primary outcome 45.8% vs 55.6% (HR 0.74 relative). LIKELY.

Watch out: The natural sequel is Shelf #2296: what to do when right-ventricular pacing is already in place and the ventricle has failed.

Source: Synthesis of Curtis AB et al. N Engl J Med. 2013 (PMID: 23614585). Registry ID as on the trial card.